The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Thermal and energy performance of green roof and cool roof: A comparison study in Shanghai area
Abstract
Abstract Green roofs and cool roofs are commonly used to improve indoor thermal environment, reduce air-conditioning load and mitigate the Urban Heat Island (UHI) effect. This study aimed to quantify the differences in thermal and energy performance between the two different roof types under the climate of Shanghai. Firstly, field experiment was conducted in the Shanghai area. Thermal performance of green roof, cool roof and common roof in summer and winter were measured. Results showed that, compared to common roof, the cool roof had an average cooling effect of 3.3 °C on the outer roof deck surface in summer, while the green roof only had a cooling effect of 2.9 °C. In winter, the green roof provided good insulation, and could improve outer surface temperature of the roof deck by an average of 3.3 °C compared to the cool roof. A hygrothermal transfer model for green roof was coupled with a dynamic building thermal performance simulation software (THERB) and validated using measured data. The coupled model was used to predict the effect of both roof types on energy performance of a public building. Simulation results showed that green roof could reduce the cooling and heating loads of the top floor by 3.6% and 6.2%, respectively. The cool roof could reduce cooling load by 3.6% and increase heating load by 10.4%. Finally, a parametric analysis was implemented. The functional mechanism of the main parameters of green and cool roof as well as their impacts on thermal and energy performance of public buildings were analyzed in detail. Conclusions drawn from this paper could provide guidance for the design optimization and application of green roof and cool roof in Shanghai area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synnefa, A., Saliari, M., & Santamouris, M. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.01.044 · Cited by 186
Kolokotroni, M., Shittu, E., Santos, T., Ramowski, L., Mollard, A., Rowe, K., Wilson, E., Filho, J. P. D. B., & Novieto, D. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.005 · Cited by 107
Cited by
Greenery as a mitigation and adaptation strategy to urban heat
Wong, N. H., Tan, C. L., Kolokotsa, D. D., & Takebayashi, H. (2021) · Nature Reviews Earth & Environment · doi:10.1038/s43017-020-00129-5 · Cited by 784
Green roofs as a nature-based solution for improving urban sustainability: Progress and perspectives
Mihalakakou, G., Souliotis, M., Papadaki, M., Menounou, P., Dimopoulos, P., Kolokotsa, D., Paravantis, J. A., Tsangrassoulis, A., Panaras, G., Giannakopoulos, E., et al. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113306 · Cited by 279
Wang, X., Li, H., & Sodoudi, S. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109082 · Cited by 270
Metadata
- Authors
- He, Y., Yu, H., Ozaki, A., & Dong, N.
- Venue
- Journal of Cleaner Production
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 267
- Pages
- 122205
- ISSN
- 0959-6526 (ISSN-L)
- OpenAlex
- W3025782301
- Cited by
- 185
- References
- 2
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.