CoChat

Design and evaluation of polarity controlled and recyclable deep eutectic solvent based biphasic system for the polarity driven extraction and separation of compounds

Tang, Weiyang, Row, Kyung Ho · 2020 · Journal of Cleaner Production
Cited by 136

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Abstract Deep eutectic solvent (DES) based extraction methods have promising applications in extracting and separating compounds from plants. In this study, a polarity controlled biphasic extraction system consisting of a hydrophilic DES phase (Hexafluoroisopropanol-choline chloride: HFIP-ChCl) and a hydrophobic DES phase (Menthol-tricaprylylmethylammonium chloride: Menthol-N8881Cl) was constructed. The DES based biphasic system was successful in the simultaneous extraction and separation of high polarity compounds, such as chlorogenic acid (CHA), quercetin (QUE) and anthocyanidins (ANT), and a low polarity compound artemisinin(ART), from Artemisia annua Leaves in a single step by the polarity driven recognition targets. By adjusting the mole ratio of the component in each DES phase, the HFIP-ChCl(1:1)/Menthol-N8881Cl(2:1) biphasic system showed the best extraction and separation performance. A conductor-like screening model for real solvents (COSMO-RS) was used to monitor and analyze the changes in the surface polarity dynamics of each DES. The results showed that the non-polar intensity increased from 11.89 to 21.06 A2 with increasing proportion of HFIP in HFIP-ChCl and the non-polar intensity weakened from 16.47 to 10.01 A2 with increasing proportion of Menthol in Menthol-N8881Cl. This model can be efficient for screening suitable DESs in a DES based biphasic extraction system to accommodate compounds with a range of polarities. Supported by the model and experimental data of the DES based biphasic system, 6.21 mg/g ART was transferred to the upper layer (Menthol-N8881Cl with 2:1 mol ratio) and 7.89 mg/g CHA, 5.5 mg/g QUE, and 8.9 mg/g ANT were transferred to the lower layer (HFIP-ChCl with 1:1 mol ratio) under the optimal condition (15/1 solvent/solid ratio, 40 °C extraction temperature, 1:1 vol ratio and 30 min extraction time). Therefore, the polarity controlled DES based biphasic extraction system was used to expand the application of DESs in the extraction and separation of bioactive compounds with various polarities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jclepro.2020.122306

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 136

Metadata

Authors
Tang, W., & Row, K. H.
Venue
Journal of Cleaner Production
Publisher
Elsevier BV
Published
2020-09
Volume
268
Pages
122306
ISSN
0959-6526 (ISSN-L)
OpenAlex
W3028461972
Cited by
136
References
19
FWCI
4.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design and evaluation of polarity controlled and recyclable deep eutectic solvent based biphasic system for the polarity driven extraction and separation of compounds. https://app.cochat.ai/papers/10.1016/j.jclepro.2020.122306
The paper
Tang, W., & Row, K. H. (2020). Design and evaluation of polarity controlled and recyclable deep eutectic solvent based biphasic system for the polarity driven extraction and separation of compounds. Journal of Cleaner Production. https://doi.org/10.1016/j.jclepro.2020.122306

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.