Radiomic Analysis of Myocardial Native T1 Imaging Discriminates Between Hypertensive Heart Disease and Hypertrophic Cardiomyopathy
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Objectives: Hypertensive heart disease (HHD) and hypertrophic cardiomyopathy (HCM) are associated with increased left ventricular wall thickness (LVWT). Contemporary guidelines define HCM as LVWT ≥15 mm unexplained by other disease, which complicates the diagnosis in cases of co-occurrences. Background: Conventional global native T1 mapping involves calculation of mean T1 values, as a surrogate for fibrosis. However, there may be differences in its spatial localization, such as diffuse and more focal fibrosis in HHD and HCM, respectively. As radiomic texture analysis (TA) can quantify spatial distributions of pixel intensity levels, we hypothesize that TA would allow differentiation between HHD and HCM. Methods: We identified 232 subjects (53 HHD, 108 HCM, 71 controls) for TA who consecutively underwent free-breathing multi-slice native T1 mapping. Four sets of texture descriptors were applied to capture spatially dependent and independent pixel statistics. Six texture features were sequentially selected with best discriminatory capacity between HHD and HCM and tested using Support Vector Machine (SVM) classifier. Each disease group was randomly split 4:1 (Feature Selection:Test Validation), where the pattern’s reproducibility was analyzed in the test validation dataset. Results: The selected texture features provided the maximum diagnostic accuracy of 86.2% (c-statistic 0.820, CI 0.769–0.903) using SVM. For the test validation dataset the pattern’s accuracy remained high at 80.0% (c-statistic 0.89, CI 0.77–1.0). Global native T1 with an accuracy of 64% separated only modestly between HHD and HCM patients (c-statistic 0.549, CI 0.452–0.640). Conclusions: Radiomics analysis of native T1 images discriminates between HHD and HCM patients and provides incremental value over global native T1 mapping.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258 · cited 2×
“The use of quantitative mapping data compared with qualitative CMR improved standardization and reflection of physical tissue properties (37).”
2011 ACCF/AHA Guideline for the Diagnosis and Treatment of Hypertrophic Cardiomyopathy
Gersh, B. J., Maron, B. J., Bonow, R. O., Dearani, J. A., Fifer, M. A., Link, M. S., Naidu, S. S., Nishimura, R. A., Ommen, S. R., Rakowski, H., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.011 · Cited by 1,276
Ganz, P., Heidecker, B., Hveem, K., Jonasson, C., Kato, S., Segal, M. R., Sterling, D. G., & Williams, S. A. (2016) · JAMA · doi:10.1001/jama.2016.5951 · Cited by 364
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Scapicchio, C., Gabelloni, M., Barucci, A., Cioni, D., Saba, L., & Neri, E. (2021) · La radiologia medica · doi:10.1007/s11547-021-01389-x · Cited by 435
Machine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Self-citation
Metadata
- Authors
- Neisius, U., El-Rewaidy, H., Nakamori, S., Rodriguez, J., Manning, W. J., & Nezafat, R.
- Venue
- JACC: Cardiovascular Imaging
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 12
- Issue
- 10
- Pages
- 1946-1954
- ISSN
- 1876-7591 (ISSN-L)
- 1936-878X
- OpenAlex
- W2909339748
- Cited by
- 198
- References
- 8
- FWCI
- 15.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiomic Analysis of Myocardial Native T1 Imaging Discriminates Between Hypertensive Heart Disease and Hypertrophic Cardiomyopathy. https://app.cochat.ai/papers/10.1016/j.jcmg.2018.11.024
- The paper
- Neisius, U., El-Rewaidy, H., Nakamori, S., Rodriguez, J., Manning, W. J., & Nezafat, R. (2019). Radiomic Analysis of Myocardial Native T1 Imaging Discriminates Between Hypertensive Heart Disease and Hypertrophic Cardiomyopathy. JACC: Cardiovascular Imaging. https://doi.org/10.1016/j.jcmg.2018.11.024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.