The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
State-of-the-Art Deep Learning in Cardiovascular Image Analysis
Open accessAbstract
Cardiovascular imaging is going to change substantially in the next decade, fueled by the deep learning revolution. For medical professionals, it is important to keep track of these developments to ensure that deep learning can have meaningful impact on clinical practice. This review aims to be a stepping stone in this process. The general concepts underlying most successful deep learning algorithms are explained, and an overview of the state-of-the-art deep learning in cardiovascular imaging is provided. This review discusses >80 papers, covering modalities ranging from cardiac magnetic resonance, computed tomography, and single-photon emission computed tomography, to intravascular optical coherence tomography and echocardiography. Many different machines learning algorithms were used throughout these papers, with the most common being convolutional neural networks. Recent algorithms such as generative adversarial models were also used. The potential implications of deep learning algorithms on clinical practice, now and in the near future, are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Unpaired image-to-image translation using cycle-consistent adversarial networks
Zhu, J.-Y., Park, T., Isola, P., & Efros, A. A. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.244 · Cited by 23,602
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Self-citationDermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Fukushima, K. (1980) · Biological Cybernetics · doi:10.1007/bf00344251 · Cited by 5,759
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
Cited by
Machine Learning and the Future of Cardiovascular Care
Quer, G., Arnaout, R., Henne, M., & Arnaout, R. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.030 · Cited by 337
Wearable Devices in Cardiovascular Medicine
Hughes, A., Shandhi, M. M. H., Master, H., Dunn, J., & Brittain, E. (2023) · Circulation Research · doi:10.1161/circresaha.122.322389 · Cited by 291
Hanneman, K., Playford, D., Dey, D., van Assen, M., Mastrodicasa, D., Cook, T. S., Gichoya, J. W., Williamson, E. E., Rubin, G. D., & on behalf of the American Heart Association Council on Cardiovascular Radiology and Intervention; and Council on Lifelong Congenital Heart Disease and Heart Health in the Young (2024) · Circulation · doi:10.1161/cir.0000000000001202 · Cited by 72
Advances in Machine Learning Approaches to Heart Failure with Preserved Ejection Fraction
Ahmad, F. S., Luo, Y., Wehbe, R. M., Thomas, J. D., & Shah, S. J. (2022) · Heart Failure Clinics · doi:10.1016/j.hfc.2021.12.002 · Cited by 34
Artificial intelligence in perinatal diagnosis and management of congenital heart disease
Reddy, C. D., Van den Eynde, J., & Kutty, S. (2022) · Seminars in Perinatology · doi:10.1016/j.semperi.2022.151588 · Cited by 32
Metadata
- Authors
- Litjens, G., Ciompi, F., Wolterink, J. M., de Vos, B. D., Leiner, T., Teuwen, J., & Išgum, I.
- Venue
- JACC: Cardiovascular Imaging
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 12
- Issue
- 8
- Pages
- 1549-1565
- ISSN
- 1876-7591 (ISSN-L)
- 1936-878X
- OpenAlex
- W2966312603
- Cited by
- 388
- References
- 54
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: State-of-the-Art Deep Learning in Cardiovascular Image Analysis. https://app.cochat.ai/papers/10.1016/j.jcmg.2019.06.009
- The paper
- Litjens, G., Ciompi, F., Wolterink, J. M., de Vos, B. D., Leiner, T., Teuwen, J., & Išgum, I. (2019). State-of-the-Art Deep Learning in Cardiovascular Image Analysis. JACC: Cardiovascular Imaging. https://doi.org/10.1016/j.jcmg.2019.06.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.