Cited by 50Voice and Speech DisordersPhonetics and Phonology ResearchStuttering Research and Treatment

Patterns of lung volume use during an extemporaneous speech task in persons with Parkinson disease

Bunton, Kate·2005·Journal of Communication Disorders

Abstract

Unlabelled This study examined patterns of lung volume use in speakers with Parkinson disease (PD) during an extemporaneous speaking task. The performance of a control group was also examined. Behaviors described are based on acoustic, kinematic and linguistic measures. Group differences were found in breath group duration, lung volume initiation, and lung volume termination measures. Speakers in the control group alternated between a longer and shorter breath groups. With starting lung volumes being higher for the longer breath groups and lower for shorter breath groups. Speech production was terminated before reaching tidal end expiratory level. This pattern was also seen in 4 of 7 speakers with PD. The remaining 3 PD speakers initiated speech at low starting lung volumes and continued speaking below EEL. This subgroup of PD speakers ended breath groups at agrammatical boundaries, whereas control speakers ended at appropriate grammatical boundaries. Learning outcomes As a result of participating in this exercise, the reader will (1) be able to describe the patterns of lung volume use in speakers with Parkinson disease and compare them with those employed by control speakers; and (2) obtain information about the influence of speaking task on speech breathing.

Integrity signals

Registry

Crossref · 10.1016/j.jcomdis.2005.01.001

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other studies have shown that speakers with Parkinson's disease initiate and terminate speech at lower-than-normal lung volumes.

    “In contrast, other studies have shown that speakers with PD initiate and terminate speech at lower-than-normal lung volumes (Bunton, 2005; Darling-White et al., 2022; Huber & Darling-White, 2017).”

    From Respiratory Responses to Two Voice Interventions for Parkinson's Disease (2022) · cites this paper as Bunton, 2005

  • Physiological changes in Parkinson's disease may adversely affect the efficiency of rest breathing and speech breathing.

    “These physiological changes may adversely affect the efficiency of rest breathing (Tzelepis et al., 1988) and speech breathing (Bunton, 2005; Huber et al., 2003) in persons with PD.”

    From Respiratory Responses to Two Voice Interventions for Parkinson's Disease (2022) · cites this paper as Bunton, 2005

  • The variability in speech breathing patterns used to support louder speech, as reflected in Figure 2 and Table 4, is consistent with prior studies of persons with PD and healthy young adults.

    “Last, the authors would like to note that the variability in speech breathing patterns used to support louder speech, as reflected in Figure 2 and Table 4, is consistent with prior studies of persons with PD (Bunton, 2005; Huber et al., 2003; Stathopoulos et al., 2014) and healthy young adults (Stathopoulos & Sapienza, 1993).”

    From Respiratory Responses to Two Voice Interventions for Parkinson's Disease (2022) · cites this paper as Bunton, 2005

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 44 · Cited by 50

Authors
Bunton, K.
Affiliations
University of Arizona (US)
Corresponding author
Bunton, Kate
Venue
Journal of Communication Disorders
Publisher
Elsevier BV
Published
2005-09
Volume
38
Issue
5
Pages
331-348
ISSN
0021-9924 (ISSN-L)
OpenAlex
W2025219907
Cited by
50
References
44
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 4 · 2019: 2 · 2018: 7 · 2017: 2 · 2016: 1 · 2015: 3 · 2014: 2 · 2013: 1 · 2012: 2
FWCI
1.20
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Communication Disorders (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5p60dc001409-10)
  • National Institute on Deafness and Other Communication Disorders (DC 01409)
Topics
  • Health Sciences › Medicine › Physiology › Voice and Speech Disorders
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Phonetics and Phonology Research
  • Social Sciences › Psychology › Clinical Psychology › Stuttering Research and Treatment
Keywords
Parkinson's disease, speech breathing, breath groups, extemporaneous speech, tidal volume, speech kinematics, speech acoustics
MeSH terms
Aged, Aged, 80 and over, Biomechanical Phenomena, Female, Humans, Linguistics, Lung, Lung Volume Measurements, Male, Middle Aged, Parkinson Disease, Speech Disorders, Speech Production Measurement, Tidal Volume, Reproducibility of Results, Case-Control Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review