Threshold size for optimal passive pulmonary targeting and retention of rigid microparticles in rats
Open accessThe DOI matches its Crossref record.
Abstract
The relationship between microparticle (MP) size and lung targeting efficiency, intra-lung distribution and retention time was systematically studied after intravenous administration of rigid fluorescent polystyrene MPs of various sizes (2, 3, 6 and 10μm) to Sprague-Dawley rats. Total fluorescence was assessed and it was found that 2μm and 3μm MPs readily passed through the lung to the liver and spleen while 10μm MPs were completely entrapped in the lung for the one-week duration of the study. Approximately 84% of 6μm MPs that were initially entrapped in the lung were cleared over the next 2 days and 15% were cleared over the remaining 5 days. A Caliper IVIS® 100 small animal imaging system confirmed that 3μm MPs were not retained in the lung but that 6μm and 10μm MPs were widely distributed throughout the lung. Moreover, histologic examination showed MP entrapment in capillaries but not arterioles. These studies suggest that for rigid MPs the optimal size range required to achieve transient but highly efficiently targeting to pulmonary capillaries after IV injection is >6μm but <10μm in rats and that systemic administration of optimally sized MPs may be an efficient alternative to currently used inhalation-based delivery to the lung.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The journey of a drug-carrier in the body: An anatomo-physiological perspective
Bertrand, N., & Leroux, J.-C. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.09.098 · Cited by 707
Interactions of nanomaterials and biological systems: Implications to personalized nanomedicine
Zhang, X.-Q., Xu, X., Bertrand, N., Pridgen, E., Swami, A., & Farokhzad, O. C. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.005 · Cited by 487
Anselmo, A. C., Modery-Pawlowski, C. L., Menegatti, S., Kumar, S., Vogus, D. R., Tian, L. L., Chen, M., Squires, T. M., Sen Gupta, A., & Mitragotri, S. (2014) · ACS Nano · doi:10.1021/nn503732m · Cited by 350
Miyazawa, T., Itaya, M., Burdeos, G. C., Nakagawa, K., & Miyazawa, T. (2021) · International Journal of Nanomedicine · doi:10.2147/ijn.s298606 · Cited by 185
“Kutscher et al found that particles with a size of 6 μm or larger accumulated in the lungs for more than a week when polystyrene microparticles of different particle sizes (2, 3, 6, and 10 μm) were administered intravenously to rats.(140) In addition, particles larger than 400 nm in size were captured by splenic filtr…”
MethodTang, Y., Han, S., Liu, H., Chen, X., Huang, L., Li, X., & Zhang, J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.087 · Cited by 147
Nanonization techniques to overcome poor water-solubility with drugs
Da Silva, F. L. O., Marques, M. B. D. F., Kato, K. C., & Carneiro, G. (2020) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2020.1750591 · Cited by 136
Pulford, B., Reim, N., Bell, A., Veatch, J., Forster, G., Bender, H., Meyerett, C., Hafeman, S., Michel, B., Johnson, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011085 · Cited by 85
“fifty times smaller than microparticles shown to become trapped in lung tissue [66].”
Background
Metadata
- Authors
- Kutscher, H. L., Chao, P., Deshmukh, M., Singh, Y., Hu, P., Joseph, L. B., Reimer, D. C., Stein, S., Laskin, D. L., & Sinko, P. J.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2010-04-02
- Volume
- 143
- Issue
- 1
- Pages
- 31-37
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2095990690
- Cited by
- 117
- References
- 0
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.