Focused ultrasound and microbubbles for enhanced extravasation
Open accessThe DOI matches its Crossref record.
Abstract
The permeability of blood vessels for albumin can be altered by using ultrasound and polymer or lipid-shelled microbubbles. The region in which the microbubbles were destroyed with focused ultrasound was quantified in gel phantoms as a function of pressure, number of cycles and type of microbubble. At 2 MPa the destruction took place in a fairly wide area for a lipid-shelled agent, while for polymer-shelled agents at this setting, distinct destruction spots with a radius of only 1 mm were obtained. When microbubbles with a thicker shell were used, the pressure above which the bubbles were destroyed shifts to higher values. In vivo both lipid and polymer microbubbles increased the extravasation of the albumin binding dye Evans Blue, especially in muscle leading to about 6–8% of the injected dose to extravasate per gram muscle tissue 30 minutes after start of the treatment, while no Evans Blue could be detected in muscle in the absence of microbubbles. Variation in the time between ultrasound treatment and Evans Blue injection, demonstrated that the time window for promoting extravasation is at least an hour at the settings used. In MC38 tumors, extravasation already occurred without ultrasound and only a trend towards enhancement with about a factor 2 could be established with a maximum percentage injected dose per gram of 3%. Ultrasound mediated microbubble destruction especially enhances the extravasation in the highly vascularized outer part of the MC38 tumor and adjacent muscle and would, therefore, be most useful for release of, for instance, anti-angiogenic drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
Phase‐shift, stimuli‐responsive perfluorocarbon nanodroplets for drug delivery to cancer
Rapoport, N. (2012) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1176 · Cited by 246
Nanoscale theranostics for physical stimulus-responsive cancer therapies
Chen, Q., Ke, H., Dai, Z., & Liu, Z. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.09.018 · Cited by 210
Nucleation, mapping and control of cavitation for drug delivery
Stride, E., & Coussios, C. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0074-y · Cited by 185
Ultrasound-mediated nano drug delivery for treating cancer: Fundamental physics to future directions
Moradi Kashkooli, F., Jakhmola, A., Hornsby, T. K., Tavakkoli, J. (., & Kolios, M. C. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2023.02.009 · Cited by 177
Metadata
- Authors
- Böhmer, M. R., Chlon, C. H. T., Raju, B. I., Chin, C. T., Shevchenko, T., & Klibanov, A. L.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2010-11
- Volume
- 148
- Issue
- 1
- Pages
- 18-24
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2088642020
- Cited by
- 103
- References
- 0
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Focused ultrasound and microbubbles for enhanced extravasation. https://app.cochat.ai/papers/10.1016/j.jconrel.2010.06.012
- The paper
- Böhmer, M. R., Chlon, C. H. T., Raju, B. I., Chin, C. T., Shevchenko, T., & Klibanov, A. L. (2010). Focused ultrasound and microbubbles for enhanced extravasation. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2010.06.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.