CoChat

A new tool to ensure the fluorescent dye labeling stability of nanocarriers: A real challenge for fluorescence imaging

Open access
Bastiat, Guillaume, Pritz, Christian Oliver, Roider, Clemens, Fouchet, Florian, Lignières, Erwann, Jesacher, Alexander, Glueckert, Rudolf, Ritsch-Marte, Monika, Schrott-Fischer, Anneliese, Saulnier, Patrick, Benoit, Jean-Pierre · 2013 · Journal of Controlled Release
Cited by 115

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Numerous studies on nanocarriers use fluorescent dye labeling to investigate their biodistribution or cellular trafficking. However, when the fluorescence dye is not grafted to the nanocarrier, the question of the stability of the labeling arises. How can it be validated that the fluorescence observed during an experiment corresponds to the nanocarriers, and not to the free dye released from the nanocarriers? Studying the integrity of the labeling is challenging. Therefore, an innovative approach to confirm the labeling stability was developed, based on the transfer of a fluorescent dye from its hosting nanocarrier to a lipophilic compartment. Lipid nanocapsules (LNC) and triglyceride oil were used as models. The protocol involved mixing of LNC suspension and oil, and then separation by centrifugation. The quality of the separation was controlled by light scattering, using the derived count rate tool. Dye transfer from loaded LNCs to the lipophilic compartment or from a lipophilic compartment containing dye to non-loaded LNC was investigated by varying the nature of the dye and the oil, the oil volume and the LNC dilution. Tensiometry was used to define the dye location in the nanocarrier. Results showed that when dyes such as Nile Red and Coumarin-6 are located in oily core, the transfer occurred in a partition-dependent manner. In contrast, when the dye was entrapped in the surfactant shell of LNCs such as lipophilic indocarbocyanines (i.e. DiO, DiI and DiD), no transfer was observed. Dye diffusion was also observed in cell culture, with Nile Red inside lipid bodies of HEI-OC1 cells, without uptake of LNCs. In contrast, DiO-loaded LNCs had to be internalized to observe fluorescence inside the cells, providing a further confirmation of the absence of transfer in this case, and the stability of fluorescence labeling of the LNCs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jconrel.2013.06.014

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 115

Metadata

Authors
Bastiat, G., Pritz, C. O., Roider, C., Fouchet, F., Lignières, E., Jesacher, A., Glueckert, R., Ritsch-Marte, M., Schrott-Fischer, A., Saulnier, P., & Benoit, J.-P.
Venue
Journal of Controlled Release
Publisher
Elsevier BV
Published
2013-09
Volume
170
Issue
3
Pages
334-342
ISSN
0168-3659 (ISSN-L)
OpenAlex
W2061999464
Cited by
115
References
3
FWCI
3.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.