Canaloplasty: Circumferential viscodilation and tensioning of Schlemm's canal using a flexible microcatheter for the treatment of open-angle glaucoma in adults: Interim clinical study analysis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the safety and efficacy of circumferential viscodilation and tensioning of the inner wall of Schlemm's canal in a new surgical procedure for the treatment of open-angle glaucoma (OAG). SETTING: Fourteen clinical sites in the United States and Germany. METHODS: In this international multicenter prospective study of adult patients with OAG having glaucoma surgery, patients with qualifying preoperative intraocular pressure (IOP) of at least 16 mm Hg or higher and open angles were eligible. Evaluation was performed at baseline and 1 day, 1 week, and 1, 3, 6, and 12 months preoperatively. After a nonpenetrating dissection technique to expose Schlemm's canal was performed, a flexible microcatheter (iTrack 250A, iScience Interventional) was used to dilate the full circumference of the canal by injecting sodium hyaluronate 1.4% (Healon GV) during catheterization. A suture loop was placed in the canal to apply tension to the trabecular meshwork. High-resolution ultrasound imaging was used to assess Schlemm's canal and anterior segment angle morphology, including distension of the trabecular meshwork caused by the tensioning suture. Data analysis was performed in 2 groups: Group 1, in which patients met all inclusion criteria, and Group 2, made up of Group 1 patients who had successful suture placement. RESULTS: Group 1 comprised 94 patients and Group 2, 74 patients. The mean baseline IOP in Group 1 was 24.7 mm Hg+/-4.8 (SD) on a mean of 1.9+/-1.0 medications per patient. In Group 2 (patients with sutures), the mean IOP was 16.1+/-4.7 mm Hg 3 months postoperatively, 15.6+/-4.0 mm Hg at 6 months, and 15.3+/-3.8 mm Hg at 1 year. Medication use dropped to a mean of 0.6+/-0.9 per patient at 12 months. Suture tensioning was an apparent contributing factor in achieving surgical success. Patients with measurable trabecular meshwork distension from suture tension had a mean IOP of 15.9+/-5.2 mm Hg at 6 months and 14.5+/-3.0 mm Hg at 12 months. Surgical and postsurgical adverse events were reported in 15 of 94 patients (16%) and included hyphema (3), elevated IOP greater than 30 mm Hg (3), Descemet's tear (1), hypotony (1), choroidal effusion (1), and exposed closure suture with eyelid edema and erythema epiphora (1); 4 patients were subsequently converted to trabeculectomy. CONCLUSION: Circumferential viscodilation and tensioning of Schlemm's canal was a safe and effective surgical procedure to reduce IOP in adult patients with OAG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00538-9 · Cited by 2,780
Ophir, A. (1992) · Eye · doi:10.1038/eye.1992.71 · Cited by 40
Cited by
Treatment Outcomes in the Tube Versus Trabeculectomy (TVT) Study After Five Years of Follow-up
Gedde, S. J., Schiffman, J. C., Feuer, W. J., Herndon, L. W., Brandt, J. D., & Budenz, D. L. (2012) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.10.026 · Cited by 1,110
Rulli, E., Biagioli, E., Riva, I., Gambirasio, G., De Simone, I., Floriani, I., & Quaranta, L. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.5059 · Cited by 265
Olsen, T. W., Feng, X., Wabner, K., Csaky, K., Pambuccian, S., & Cameron, J. D. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6291 · Cited by 106
Kang-Mieler, J. J., Dosmar, E., Liu, W., & Mieler, W. F. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1227785 · Cited by 73
Peden, M. C., Min, J., Meyers, C., Lukowski, Z., Li, Q., Boye, S. L., Levine, M., Hauswirth, W. W., Ratnakaram, R., Dawson, W., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017140 · Cited by 63
Metadata
- Authors
- Lewis, R. A., von Wolff, K., Tetz, M., Korber, N., Kearney, J. R., Shingleton, B., & Samuelson, T. W.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2007-07
- Volume
- 33
- Issue
- 7
- Pages
- 1217-1226
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2593289409
- Cited by
- 262
- References
- 2
- FWCI
- 13.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Canaloplasty: Circumferential viscodilation and tensioning of Schlemm's canal using a flexible microcatheter for the treatment of open-angle glaucoma in adults: Interim clinical study analysis. https://app.cochat.ai/papers/10.1016/j.jcrs.2007.03.051
- The paper
- Lewis, R. A., von Wolff, K., Tetz, M., Korber, N., Kearney, J. R., Shingleton, B., & Samuelson, T. W. (2007). Canaloplasty: Circumferential viscodilation and tensioning of Schlemm's canal using a flexible microcatheter for the treatment of open-angle glaucoma in adults: Interim clinical study analysis. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2007.03.051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.