Subjective depth of field in presence of 4th-order and 6th-order Zernike spherical aberration using adaptive optics technology
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To study the impact on the subjective depth of field of 4th-order spherical aberration and its combination with 6th-order spherical aberration and analyze the accuracy of image-quality metrics in predicting the impact. SETTING: Laboratoire Aimé Cotton, Centre National de la Recherche Scientifique, Université Paris-Sud, Orsay, France. DESIGN: Case series. METHODS: Subjective depth of field was defined as the range of defocus at which the target (3 high-contrast letters at 20/50) was perceived acceptable. Depth of field was measured using 0.18 diopter (D) steps in young subjects with the addition of the following spherical aberration values: ±0.3 μm and ±0.6 μm 4th-order spherical aberration with 3.0 mm and 6.0 mm pupils and ±0.3 μm 4th-order spherical aberration with ±0.1 μm 6th-order spherical aberration for 6.0 mm pupils. RESULTS: The addition of ±0.3 and ±0.6 μm 4th-order spherical aberration increased depth of field by 30% and 45%, respectively. The combination of 4th-order spherical aberration and 6th-order spherical aberration of opposite signs increased depth of field more than 4th-order spherical aberration alone (ie, 63%), while the combination of 4th-order spherical aberration and 6th-order spherical aberration of the same signs did not (ie, 24%). Whereas the midpoint of the depth of field could be predicted by image-quality metrics, none was found a good predictor of objectionable depth of field. CONCLUSION: Subjective depth of field increased when 4th-order spherical aberration and 6th-order spherical aberration of opposite signs were added but could not be predicted with image-quality metrics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metrics of optical quality derived from wave aberrations predict visual performance
Marsack, J. D., Thibos, L. N., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.8 · Cited by 341
Cited by
Power profiles of multifocal contact lenses and their interpretation
Plainis, S., Atchison, D. A., & Charman, W. N. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000030 · Cited by 115
Benard, Y., Lopez-Gil, N., & Legras, R. (2011) · Vision Research · doi:10.1016/j.visres.2011.10.003 · Cited by 101
Self-citationLegras, R., Benard, Y., & Lopez-Gil, N. (2012) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.10.032 · Cited by 46
Self-citation
Metadata
- Authors
- Benard, Y., Lopez-Gil, N., & Legras, R.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2010-12
- Volume
- 36
- Issue
- 12
- Pages
- 2129-2138
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W1985351267
- Cited by
- 85
- References
- 1
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subjective depth of field in presence of 4th-order and 6th-order Zernike spherical aberration using adaptive optics technology. https://app.cochat.ai/papers/10.1016/j.jcrs.2010.07.022
- The paper
- Benard, Y., Lopez-Gil, N., & Legras, R. (2010). Subjective depth of field in presence of 4th-order and 6th-order Zernike spherical aberration using adaptive optics technology. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2010.07.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.