The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Corneal thickness changes after corneal collagen crosslinking for keratoconus and corneal ectasia: One-year results
Abstract
PURPOSE: To determine the changes in corneal thickness over time after corneal collagen crosslinking (CXL) for keratoconus and corneal ectasia. SETTING: Cornea and refractive surgery subspecialty practice. DESIGN: Prospective randomized controlled clinical trial. METHODS: Corneal thickness at the apex, thinnest point, and pupil center were measured using Scheimpflug imaging (Pentacam) at baseline and 1, 3, 6, and 12 months after CXL. The treatment group was compared with both a sham-procedure control group and a fellow-eye control group. Associations with clinical outcomes (uncorrected and corrected distance visual acuities and maximum keratometry) were analyzed. RESULTS: The study comprised 82 eyes, 54 with keratoconus and 28 with ectasia after laser in situ keratomileusis. The mean preoperative thinnest pachymetry was 440.7 μm ± 52.9 (SD). After CXL, the cornea thinned at 1 month (mean change -23.8 ± 28.7 μm; P<.001) and from 1 to 3 months (mean change -7.2 ± 20.1 μm, P=.002), followed by a recovery of the corneal thickness between 3 months and 6 months (mean +20.5 ± 20.4 μm; P<.001). At 1 year, apex and pupil-center thicknesses returned to baseline (P=.11 and P=.06, respectively); however, the thinnest pachymetry remained slightly decreased from baseline to 12 months (mean change -6.6 ± 22.4 μm; P=.01). The recovery of corneal thickness was more rapid in ectasia than in keratoconus. There was no association between the degree of corneal thinning at 3 months and clinical outcomes after CXL. CONCLUSIONS: After CXL, the cornea thins and then recovers toward baseline thickness. The cause and implications of corneal thickness changes after CXL remain to be elucidated. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The cellular basis of corneal transparency: evidence for 'corneal crystallins'
Jester, J. V., Moller-Pedersen, T., Huang, J., Sax, C. M., Kays, W. T., Cavangh, H. D., Petroll, W. M., & Piatigorsky, J. (1999) · Journal of Cell Science · doi:10.1242/jcs.112.5.613 · Cited by 503
Cited by
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
Risk Factors for Progression to Penetrating Keratoplasty in Patients With Keratoconus
Reeves, S. W., Stinnett, S., Adelman, R. A., & Afshari, N. A. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.029 · Cited by 290
Wavelength-dependent ultraviolet induction of cyclobutane pyrimidine dimers in the human cornea
Mallet, J. D., & Rochette, P. J. (2013) · Photochemical & Photobiological Sciences · doi:10.1039/c3pp25408a · Cited by 65
Metadata
- Authors
- Greenstein, S. A., Shah, V. P., Fry, K. L., & Hersh, P. S.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2011-04
- Volume
- 37
- Issue
- 4
- Pages
- 691-700
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2070787816
- Cited by
- 236
- References
- 1
- FWCI
- 13.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corneal thickness changes after corneal collagen crosslinking for keratoconus and corneal ectasia: One-year results. https://app.cochat.ai/papers/10.1016/j.jcrs.2010.10.052
- The paper
- Greenstein, S. A., Shah, V. P., Fry, K. L., & Hersh, P. S. (2011). Corneal thickness changes after corneal collagen crosslinking for keratoconus and corneal ectasia: One-year results. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2010.10.052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.