Machine learning-driven label-free cell sorting for CAR-T cell manufacturing
The DOI matches its Crossref record.
Abstract
Background & Aim We have developed a label-free high throughput machine learning-driven cell sorter based on cells’ morphological information. The cytometer acquires cell-specific waveform signals containing morphologic information from a defined training set. After a supervised machine learning model is developed from the training set, the cell of interest can be classified and sorted based on the scores obtained by the machine learning model. We investigated that the label-free cell classification and sorting of CAR-T cells to improve manufacturing process. CAR-T therapy has shown innovative therapeutic effects in leukemia treatment. However, many clinical studies have been conducted and the clinical results indicated that quality control for the therapeutic cell production process is always an issue for any cell therapy manufacturing process. Also, an ideal CAR-T cell population or “High-Quality CAR-T” with regard to a T cell subset, phenotype, and CAR construct is under investigation. Detailed analysis of CAR-T cells administered to CLL patients have been conducted and the results revealed the important features of clinically active CAR-T such as its glycolysis status, early memory phenotype or exhaustion low profile. Methods, Results & Conclusion To avoid CAR-T manufacturing failure and/or improve the CAR-T quality, it is necessary to collect enough healthy and functional T cells from the patient by leukapheresis in the manufacturing process. We investigated that our label-free cytometer can discriminate healthy T cells from samples after hemolysis process, wherein CD3 positive T cells and other cells were used as a training set to develop the T cell classifier model. The accuracy of the label-free discrimination of T cells was found to be very high. This label-free classification may allow us to perform the quality control of CAR-T manufacturing without the use of surface markers and at the minimal sample loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Several works within basic research and clinical biomanufacturing spheres have been published with this mindset, though the field of iPSC biomanufacturing has yet to rigorously explore these opportunities82–84.”
From Induced pluripotency in the context of stem cell expansion bioprocess development, optimization, and manufacturing: a roadmap to the clinic (2021) · cites this paper as [83]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Colter, J., Murari, K., Biernaskie, J., & Kallos, M. S. (2021) · npj Regenerative Medicine · doi:10.1038/s41536-021-00183-7 · Cited by 33
Metadata
- Authors
- Sugimoto, K.
- Venue
- Cytotherapy
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 21
- Issue
- 5
- Pages
- S39
- ISSN
- 1465-3249
- Cited by
- 7
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Machine learning-driven label-free cell sorting for CAR-T cell manufacturing. https://app.cochat.ai/papers/10.1016/j.jcyt.2019.03.376
- The paper
- Sugimoto, K. (2019). Machine learning-driven label-free cell sorting for CAR-T cell manufacturing. Cytotherapy. https://doi.org/10.1016/j.jcyt.2019.03.376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.