The effect of metal ions released from different dental implant-abutment couples on osteoblast function and secretion of bone resorbing mediators
Open accessAbstract
OBJECTIVES: The etiology of the reduced marginal bone loss observed around platform-switched implant-abutment connections is not clear but could be related to the release of variable amounts of corrosion products. The present study evaluated the effect of different concentrations of metal ions released from different implant abutment couples on osteoblastic cell viability, apoptosis and expression of genes related to bone resorption. METHODS: Osteoblastic cells were exposed to five conditions of culture media prepared containing metal ions (titanium, aluminum, vanadium, cobalt, chromium and molybdenum) in different concentrations representing the amounts released from platform-matched and platform-switched implant-abutment couples as a result of an earlier accelerated corrosion experiment. Cell viability was evaluated over 21days using the Alamar Blue assay. Induction of apoptosis was measured after 24h of exposure using flow cytometry. Expression of interleukin-6, interleukin-8, cyclooxygenase-2, caspase-8, osteoprotegerin and receptor activator of nuclear factor kappa-B ligand (RANKL) by osteoblastic cells were analysed after exposure for 1, 3 and 21days using real-time quantitative polymerase chain reaction assay RESULTS: Metal ions in concentrations representing the platform-matched groups led to a reduction in cell viability (P<0.01) up to 7days of exposure. Stimulated cells showed higher rates of early apoptosis (P<0.01) compared to non-treated cells. Metal ions up-regulated the expression of interleukin-6, interleukin-8, cyclooxygenase-2 and RANKL in a dose dependent manner after 1day of exposure (P<0.05). The up-regulation was more pronounced in the groups containing the corrosion products of platform-matched implant-abutment couples. CONCLUSION: Osteoblastic cell viability, apoptosis, and regulation of bone resorbing mediators were significantly altered in the presence of metal ions. The change in cytokine levels expressed was directly proportional to the metal ion concentration. CLINICAL SIGNIFICANCE: The observed biological responses to decreased amounts of metal ions released from platform-switched implant-abutment couples compared to platform-matched couples may partly explain the positive radiographic findings in respect to crestal bone level when utilising the "platform-switching" concept, which highlights the possible role of corrosion products in the mediation of crestal bone loss around dental implants.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Metal ions in osteoblastic cell culture media induce the production of proinflammatory cytokines such as IL-8 and IL-6.
“it has been shown that the presence of metal ions in osteoblastic cell culture media induces the production of proinflammatory cytokines such as IL-8, a potent chemoattractant for phagocytes (macrophages and neutrophils), and IL-6, an activator of osteoclasts [146].”
From Potential Impact of Prosthetic Biomaterials on the Periodontium: A Comprehensive Review (2023) · cites this paper as [146]
The citation lists haven’t been fetched yet
References 62 · Cited by 85
- Authors
- Alrabeah, G. O., Brett, P., Knowles, J. C., & Petridis, H.
- Affiliations
- King Saud University (SA)
- University College London (GB)
- Corresponding author
- Petridis, Haralampos
- Venue
- Journal of Dentistry
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 66
- Pages
- 91-101
- ISSN
- 0300-5712 (ISSN-L)
- OpenAlex
- W2742745215
- Cited by
- 85
- References
- 62
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 5 · 2023: 18 · 2022: 8 · 2021: 14 · 2020: 13 · 2019: 13 · 2018: 4
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Dentistry (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- King Saud University, Kingdom of Saudi Arabia
- Topics
- Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Keywords
- dental implants, implant-abutment connection, platform switching, metal ion release, corrosion products, osteoblast viability, osteoblast apoptosis, bone resorption, RANKL, osteoprotegerin, cyclooxygenase-2, interleukin-6, interleukin-8, titanium, marginal bone loss, crestal bone level
- MeSH terms
- Dental Abutments, Aluminum, Cell Survival, Chromium, Cobalt, Corrosion, Dental Alloys, Dental Implantation, Endosseous, Humans, Ions, Metals, Molybdenum, Osteoblasts, Time Factors, Titanium, Vanadium, Interleukin-6, Gene Expression, Dental Implants, Interleukin-8, Alveolar Bone Loss, Apoptosis, Cell Culture Techniques, Cyclooxygenase 2, Caspase 8, Osteoprotegerin, RANK Ligand, Dental Implant-Abutment Design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review