Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Ultrasensitive and stable X-ray detection using zero-dimensional lead-free perovskites

Open access
Zheng, Xiaojia, Zhao, Wei, Wang, Peng, Tan, Hairen, Saidaminov, Makhsud I., Tie, Shujie, Chen, Ligao, Peng, Yufei, Long, Jidong, Zhang, Wen-Hua·2020·Journal of Energy Chemistry

Abstract

Sensitive and reliable X-ray detectors are essential for medical radiography, industrial inspection and security screening. Lowering the radiation dose allows reduced health risks and increased frequency and fidelity of diagnostic technologies for earlier detection of disease and its recurrence. Three-dimensional (3D) organic–inorganic hybrid lead halide perovskites are promising for direct X-ray detection – they show improved sensitivity compared to conventional X-ray detectors. However, their high and unstable dark current, caused by ion migration and high dark carrier concentration in the 3D hybrid perovskites, limits their performance and long-term operation stability. Here we report ultrasensitive, stable X-ray detectors made using zero-dimensional (0D) methylammonium bismuth iodide perovskite (MA3Bi2I9) single crystals. The 0D crystal structure leads to a high activation energy (Ea) for ion migration (0.46 eV) and is also accompanied by a low dark carrier concentration (~ 106 cm−3). The X-ray detectors exhibit sensitivity of 10,620 µC Gyair−1 cm−2, a limit of detection (LoD) of 0.62 nGyair s−1, and stable operation even under high applied biases; no deterioration in detection performance was observed following sensing of an integrated X-ray irradiation dose of ~23,800 mGyair, equivalent to > 200,000 times the dose required for a single commercial X-ray chest radiograph. Regulating the ion migration channels and decreasing the dark carrier concentration in perovskites provide routes for stable and ultrasensitive X-ray detectors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jechem.2020.02.049

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 237

Metadata

Authors
Zheng, X., Zhao, W., Wang, P., Tan, H., Saidaminov, M. I., Tie, S., Chen, L., Peng, Y., Long, J., & Zhang, W.-H.
Venue
Journal of Energy Chemistry
Publisher
Elsevier BV
Published
2020-10
Volume
49
Pages
299-306
ISSN
2095-4956 (ISSN-L)
OpenAlex
W3009467181
Cited by
237
References
1
FWCI
12.15
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasensitive and stable X-ray detection using zero-dimensional lead-free perovskites. https://app.cochat.ai/papers/10.1016/j.jechem.2020.02.049
The paper
Zheng, X., Zhao, W., Wang, P., Tan, H., Saidaminov, M. I., Tie, S., Chen, L., Peng, Y., Long, J., & Zhang, W.-H. (2020). Ultrasensitive and stable X-ray detection using zero-dimensional lead-free perovskites. Journal of Energy Chemistry. https://doi.org/10.1016/j.jechem.2020.02.049

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.