The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone
Open accessAbstract
In this report, a voltammetric sensor for simultaneous determination of hydroquinone (HQ) and catechol (CC) was developed at a glassy carbon electrode modified with graphene (GR/GCE). The separation of oxidation and reduction peak (ΔE) is decreased from 281 to 31 mV for HQ and from 250 to 26 mV for CC at GR/GCE, respectively. Separation of the oxidation peak potentials for HQ and CC was about 112 mV in 0.10 M acetate buffer solution (pH 4.5), and the anodic currents for the oxidation of both HQ and CC are greatly increased at GR/GCE, which makes it suitable for simultaneous determination of these compounds. Under the optimized condition, the anodic peak current of HQ is linear with the concentration of HQ from 1 × 10−6 to 5 × 10−5 M in the presence of 5 × 10−5 M CC. A detection limit of 1.5 × 10−8 M (S/N = 3) can be achieved. At the same time, the anodic current of CC is linear with the concentration of CC from 1 × 10−6 to 5 × 10−5 M with a detection limit of 1.0 × 10−8 M (S/N = 3) in the presence of 5 × 10−5 M HQ. The proposed sensor was successfully applied to the simultaneous determination of HQ and CC in tap water, and the results are satisfactory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Superior Thermal Conductivity of Single-Layer Graphene
Balandin, A. A., Ghosh, S., Bao, W., Calizo, I., Teweldebrhan, D., Miao, F., & Lau, C. N. (2008) · Nano Letters · doi:10.1021/nl0731872 · Cited by 13,823
Cited by
Graphene Oxide: Preparation, Functionalization, and Electrochemical Applications
Chen, D., Feng, H., & Li, J. (2012) · Chemical Reviews · doi:10.1021/cr300115g · Cited by 3,531
Biological and chemical sensors based on graphene materials
Liu, Y., Dong, X., & Chen, P. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15270j · Cited by 1,748
Hill, E. W., Vijayaragahvan, A., & Novoselov, K. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2167608 · Cited by 432
Electrochemical sensors based on graphene materials
Gan, T., & Hu, S. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0639-7 · Cited by 349
Nanomaterial-based electrochemical sensing of neurological drugs and neurotransmitters
Sanghavi, B. J., Wolfbeis, O. S., Hirsch, T., & Swami, N. S. (2015) · Microchimica Acta · doi:10.1007/s00604-014-1308-4 · Cited by 328
Metadata
- Authors
- Du, H., Ye, J., Zhang, J., Huang, X., & Yu, C.
- Venue
- Journal of Electroanalytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 650
- Issue
- 2
- Pages
- 209-213
- ISSN
- 1572-6657 (ISSN-L)
- OpenAlex
- W2029539351
- Cited by
- 241
- References
- 1
- FWCI
- 15.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone. https://app.cochat.ai/papers/10.1016/j.jelechem.2010.10.002
- The paper
- Du, H., Ye, J., Zhang, J., Huang, X., & Yu, C. (2011). A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone. Journal of Electroanalytical Chemistry. https://doi.org/10.1016/j.jelechem.2010.10.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.