CoChat

A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II)

Tamiji, Tahmineh, Nezamzadeh-Ejhieh, Alireza · 2018 · Journal of Electroanalytical Chemistry
Cited by 146

The DOI matches its Crossref record.

Abstract

The Sn(IV) ion exchanged clinoptilolite nanoparticles (Sn(IV)-CNP) were used as a modifier for the modification of carbon paste electrode (CPE). When the modified electrode was immersed in HCl supporting electrolyte, Sn(IV) cations can locate at the Sn(IV)-CNP-CPE electrode surface via an ion exchange process with protons of the supporting electrolyte. These electroactive cations underwent a redox process at the electrode surface. Increased peak current of Sn(IV) reduction by adding Hg(II) analyte into the supporting electrolyte solution was used for the voltammetric determination of Hg(II). Focus of the work was on study of the interaction effects between the influencing variables in square wave voltammetric response of the modified electrode in the presence of Hg(II) cations by designing the experiments (via response surface methodology: RSM) and study of some kinetic aspects of the process in linear sweep voltammetry and chronoamperometry. The optimal run in RSM was obtained in: Csn(IV) in ion exchange solution: 0.37 mol L−1, modifier%: 22.45, amplitude: 60 mV and step potential: 2.9 mV. The response current of the modified electrode was proportion to Hg(II) concentration in the range of 0.1–10 μM (DL: 0.05 μM) in square wave voltammetry and in the range of 0.1–10 μM (DL: 0.01 μM) in chronoamperometry. Using the Tafel plots, the values of α and Ko were determined for the modified electrode as 0.298, 1.91 × 10−3 s−1 and 0.311, 6.62 × 10−3 s−1 in the absence and presence of Hg(II) cations, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jelechem.2018.10.011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 61

  1. Eisler, 1987, Mercury hazards to fish, wildlife, and invertebrates: a synoptic review, 85, 1
  2. Clarkson, 1992, Mercury: major issues in environmental health, Environ. Health Perspect., 100, 31, 10.1289/ehp.9310031 · DOI
  3. Sigel, 1997, Metal ions in biological systems, vol. 34
  4. Wagner-Döbler, 2003, Pilot plant for bioremediation of mercury-containing industrial wastewater, Appl. Microbiol. Biotechnol., 62, 124, 10.1007/s00253-003-1322-7 · DOI
  5. Mason, 1994, The biogeochemical cycling of elemental mercury: anthropogenic influences, Geochim. Cosmochim. Acta, 58, 3191, 10.1016/0016-7037(94)90046-9 · DOI · Paper page
  6. Laffont, 2009, Environ. Sci. Technol., 43, 8985, 10.1021/es9019518 · doi:10.1021/es9019518
  7. Leopold, 2010, Methods for the determination and speciation of mercury in natural waters - a review, Anal. Chim. Acta, 663, 127, 10.1016/j.aca.2010.01.048 · DOI · Paper page
  8. Sideeq Bhat, 2018, Fully nozzle-jet printed non-enzymatic electrode for biosensing application, J. Colloid Interface Sci., 512, 480, 10.1016/j.jcis.2017.10.088 · doi:10.1016/j.jcis.2017.10.088
  9. Ehsani, 2017, Electrocatalytic oxidation of ethanol on the surface of the POAP/phosphoric acid-doped ionic liquid-functionalized graphene oxide nanocomposite film, Iran. J. Catal., 7, 187
  10. Zhang, 2015, 3D porous metal-organic framework as an efficient electrocatalyst for nonenzymatic sensing application, Talanta, 144, 1176, 10.1016/j.talanta.2015.07.091 · DOI
  11. Gervais, 2018, Study of an AuNPs functionalized electrode using different diazonium salts for the ultra-fast detection of Hg(II) traces in water, Electrochim. Acta, 261, 346, 10.1016/j.electacta.2017.12.136 · doi:10.1016/j.electacta.2017.12.136
  12. Zahid, 2017, A functional graphene oxide-ionic liquid composites–gold nanoparticle sensing platform for ultrasensitive electrochemical detection of Hg2+, Electrochim. Acta, 235, 72, 10.1016/j.electacta.2017.03.120 · DOI
  13. Kalate Bojdi, 2016, Application of a novel electrochemical sensor based on modified siliceous mesocellular foam for electrochemical detection of ultra-trace amounts of mercury ions, New J. Chem., 40, 4519, 10.1039/C5NJ02973B · doi:10.1039/c5nj02973b
  14. Ayranci, 2017, Rhodamine-based conjugated polymers: potentiometric, colorimetric and voltammetric sensing of mercury ions in aqueous medium, Analyst, 142, 3407, 10.1039/C7AN00606C · DOI
  15. Bernalte, 2011, Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes, Anal. Chim. Acta, 689, 60, 10.1016/j.aca.2011.01.042 · DOI
  16. Guerreiro, 2014, Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry, Anal. Chim. Acta, 810, 79, 10.1016/j.aca.2013.12.005 · DOI
  17. Li, 2018, Nickel oxyhydroxide-functionalized n-silicon photoelectrode for the photocurrent determination of Hg(II) ions at zero working voltage, Sensors Actuators B Chem., 257, 9, 10.1016/j.snb.2017.10.125 · doi:10.1016/j.snb.2017.10.125
  18. Chira, 2014, Electrode-modified with nanoparticles composed of 4,4′-bipyridine-silver coordination polymer for sensitive determination of Hg(II), Cu(II) and Pb(II), New J. Chem., 38, 5641, 10.1039/C4NJ01245C · DOI
  19. Damien, 1994, Tutorial review. Voltammetric determination of trace metals and organics after accumulation at modified electrodes, Analyst, 119, 1953, 10.1039/an9941901953 · doi:10.1039/an9941901953
  20. Lipskikh, 2018, Sensors for voltammetric determination of food azo dyes - a critical review, Electrochim. Acta, 260, 974, 10.1016/j.electacta.2017.12.027 · DOI
  21. Deshmukh, 2018, EDTA_PANI/SWCNTs nanocomposite modified electrode for electrochemical determination of copper (II), lead (II) and mercury (II) ions, Electrochim. Acta, 259, 930, 10.1016/j.electacta.2017.10.131 · DOI · Paper page
  22. Jayadevimanoranjitham, 2018, 2,4,6-Trimercaptotriazine incorporated gold nanoparticle modified electrode for anodic stripping voltammetric determination of Hg(II), Appl. Surf. Sci., 448, 444, 10.1016/j.apsusc.2018.04.096 · DOI
  23. Deshmukh, 2018, EDTA-modified PANI/SWNTs nanocomposite for differential pulse voltammetry based determination of Cu(II) ions, Sensors Actuators B Chem., 260, 331, 10.1016/j.snb.2017.12.160 · DOI
  24. N. Jeromiyas, E. Elaiyappillai, A. Senthil Kumar, Sh.-T. Huang, V. Mani, Bismuth nanoparticles decorated graphenated carbon nanotubes modified screen-printed electrode for mercury detection, J. Taiwan Inst. Chem. Eng. https://doi.org/10.1016/j.jtice.2018.08.030. · DOI
  25. Md Isa, 2017, Chloroplatinum(II) complex-modified MWCNTs paste electrode for electrochemical determination of mercury in skin lightening cosmetics, Electrochim. Acta, 253, 463, 10.1016/j.electacta.2017.09.092 · DOI
  26. Sahoo, 2015, Solvothermal synthesis of reduced graphene oxide/Au nanocomposite-modified electrode for the determination of inorganic mercury and electrochemical oxidation of toxic phenolic compounds, Electrochim. Acta, 180, 1023, 10.1016/j.electacta.2015.09.018 · doi:10.1016/j.electacta.2015.09.018
  27. Zhang, 2016, One-step fabrication of electrochemical biosensor based on DNA-modified three-dimensional reduced graphene oxide and chitosan nanocomposite for highly sensitive detection of Hg(II), Sensors Actuators B Chem., 225, 453, 10.1016/j.snb.2015.11.091 · DOI
  28. Zuo, 2016, Poly(3,4-ethylenedioxythiophene) nanorods/graphene oxide nanocomposite as a new electrode material for the selective electrochemical detection of mercury (II), Synth. Met., 220, 14, 10.1016/j.synthmet.2016.05.022 · doi:10.1016/j.synthmet.2016.05.022
  29. Daniel Arulraj, 2016, Femtomolar detection of mercuric ions using polypyrrole, pectin and graphene nanocomposites modified electrode, J. Colloid Interface Sci., 483, 268, 10.1016/j.jcis.2016.08.026 · doi:10.1016/j.jcis.2016.08.026
  30. Zuo, 2017, Utilization of AuNPs dotted S-doped carbon nanoflakes as electrochemical sensing platform for simultaneous determination of Cu (II) and Hg (II), J. Electroanal. Chem., 794, 71, 10.1016/j.jelechem.2017.04.002 · DOI
  31. Palanisamy, 2017, Synthesis and characterization of polypyrrole decoratedgraphene/-cyclodextrin composite for low level electrochemicaldetection of mercury (II) in water, Sensors Actuators B, 243, 888, 10.1016/j.snb.2016.12.068 · doi:10.1016/j.snb.2016.12.068
  32. Gumpu, 2017, Simultaneous electrochemical detection of Cd(II), Pb(II), As(III) and Hg(II) ions using ruthenium(II)-textured graphene oxide nanocomposite, Talanta, 162, 574, 10.1016/j.talanta.2016.10.076 · DOI
  33. Walcarius, 2008, Electroanalytical applications of microporous zeolites and mesoporous (Organo) Silicas: recent trends, Electroanalysis, 20, 711, 10.1002/elan.200704144 · DOI
  34. Kaur, 2015, Ultratrace detection of toxic heavy metal ions found in water bodies using hydroxyapatite supported nanocrystalline ZSM-5 modified electrodes, New J. Chem., 39, 5137, 10.1039/C4NJ02369B · DOI
  35. Rolison, 1990, Zeolite-modified electrodes and electrode-modified zeolites, Chem. Rev., 90, 867, 10.1021/cr00103a011 · doi:10.1021/cr00103a011
  36. Daas, 2016, Fuel cell applications of chemically synthesized zeolite modified electrode (ZME) as catalyst for alcohol electro-oxidation - a review, J. Electroanal. Chem., 783, 308, 10.1016/j.jelechem.2016.11.004 · doi:10.1016/j.jelechem.2016.11.004
  37. Walcarius, 1999, Zeolite-modified electrodes in electroanalytical chemistry, Anal. Chim. Acta, 384, 1, 10.1016/S0003-2670(98)00849-6 · DOI
  38. Kaur, 2015, Synthesis of NiCo2O4/Nano-ZSM-5 nanocomposite material with enhanced electrochemical properties for the simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan, New J. Chem., 39, 1115, 10.1039/C4NJ01360C · DOI
  39. Hosseini, 2017, Photocatalytic degradation of rhodamine B by nano bismuth oxide: process modeling by response surface methodology (RSM), Iranian J. Catal., 7, 37
  40. Arabpour, 2016, Photodegradation of cotrimaxazole by clinoptilolite-supported nickel oxide, Process. Saf. Environ. Prot., 102, 431, 10.1016/j.psep.2016.04.025 · doi:10.1016/j.psep.2016.04.025
  41. Aghdasi, 2016, Photocatalytic degradation of ciprofloxacin in the presence of synthesized ZnO nanocatalyst: the effect of operational parameters, Iran. J. Catal., 6, 481
  42. Amiri, 2015, Improvement of the photocatalytic activity of cupric oxide by deposition onto a natural clinoptilolite substrate, Mater. Sci. Semicond. Process., 31, 501, 10.1016/j.mssp.2014.12.030 · doi:10.1016/j.mssp.2014.12.030
  43. Nezamzadeh-Ejhieh, 2011, Heterogeneous photocatalytic degradation of furfural using NiS-clinoptilolite zeolite, Desalination, 273, 248, 10.1016/j.desal.2010.12.031 · DOI
  44. Nezamzadeh-Ejhieh, 2013, Modification of clinoptilolite nano-particles with hexadecylpyridynium bromide surfactant as an active component of Cr(VI) selective electrode, J. Ind. Eng. Chem., 19, 2026, 10.1016/j.jiec.2013.03.018 · doi:10.1016/j.jiec.2013.03.018
  45. Brubaker, 1955, The hydrolysis of tin(1V) in sulfuric acid, J. Am. Chem. Soc., 77, 5265, 10.1021/ja01625a013 · doi:10.1021/ja01625a013
  46. Karimi Shervedani, 2009, Electrochemical impedance spectroscopy as a transduction method for electrochemical recognition of zirconium on gold electrode modified with hydroxamated self-assembled monolayer, Sensors Actuators B, 139, 657, 10.1016/j.snb.2009.03.060 · doi:10.1016/j.snb.2009.03.060
  47. Velasco, 1997, Determination of standard rate constants for electrochemical irreversible processes from linear sweep voltammograms, Electroanalysis, 9, 880, 10.1002/elan.1140091116 · DOI
  48. Xu, 2009, Colorimetric detection of mercury ion (Hg2+) based on DNA oligonucleotides and unmodified gold nanoparticles sensing system with a tunable detection range, Biosens. Bioelectron., 24, 3153, 10.1016/j.bios.2009.03.025 · DOI · Paper page
  49. Liu, 2010, Gold nanoparticle-based colorimetric and “turn-on” fluorescent probe for mercury(II) ions in aqueous solution, Anal. Chem., 82, 9021
  50. Lee, 2007, Colorimetric detection of mercuric ion (Hg2+) in aqueous media using DNA-functionalized gold nanoparticles, Angew. Chem., 119, 4171, 10.1002/ange.200700269 · DOI · Paper page
  51. Guo, 2017, Determination of Hg2+ based on the selective enhancement of peroxidase mimetic activity of hollow porous gold nanoparticles, Nano, 12, 10.1142/S1793292017500503 · doi:10.1142/s1793292017500503
  52. Kim, 2007, Ratiometric determination of Hg2+ ions based on simple molecular motifs of pyrene and dioxaoctanediamide, Org. Lett., 9, 1129, 10.1021/ol070143r · doi:10.1021/ol070143r
  53. Lu, 2003, Voltammetric determination of mercury (II) in aqueous media using glassy carbon electrodes modified with novel Cali x[4]arene, Talanta, 59, 553, 10.1016/S0039-9140(02)00569-6 · doi:10.1016/s0039-9140(02)00569-6
  54. Wang, 2010, Colorimetric biosensing of mercury(II) ion using unmodified gold nanoparticleprobes and thrombin-binding aptamer, Biosens. Bioelectron., 25, 1994, 10.1016/j.bios.2010.01.014 · DOI · Paper page
  55. Gan, 1997, Copolymers of N-acryloyl-N'-metbylpiperazine and methyl methylacrylate were synthesized and its application for Hg(II) detection by anodic striping voltammetry, Eur. Polym. J., 33, 615, 10.1016/S0014-3057(96)00227-3 · doi:10.1016/s0014-3057(96)00227-3
  56. Nascimento, 2012, Complexation of Hg(II) by humic acid studied by square wave stripping voltammetry at screen-printed gold electrodes, Talanta, 100, 57, 10.1016/j.talanta.2012.08.018 · doi:10.1016/j.talanta.2012.08.018
  57. Hezard, 2012, Gold nanoparticles electrodeposited on glassy carbon using cyclic voltammetry: application to Hg(II) trace analysis, J. Electroanal. Chem., 664, 46, 10.1016/j.jelechem.2011.10.014 · DOI · Paper page
  58. Han, 2009, A regenerative electrochemical sensor based on oligonucleotide for the selective determination of mercury(II), Analyst, 134, 1857, 10.1039/b908457f · DOI
  59. Lahrich, 2016, Catalytic effect of potassium in Na1-xKxCdPb3(PO4)3 to detect mercury (II) in fish and seawater using a carbon paste electrode, Talanta, 149, 158, 10.1016/j.talanta.2015.11.055 · DOI
  60. Xing, 2016, Highly sensitive simultaneous determination of cadmium (II), lead (II), copper (II), and mercury (II) ions on N-doped graphene modified electrode, J. Electroanal. Chem., 760, 52, 10.1016/j.jelechem.2015.11.043 · DOI
  61. Ozkorucuklu, 2017, Voltammetric determination of mercury(II) using a modified pencil graphite electrode with 4-(4-methylphenyl amino iso-nitrosoacetyl) biphenyl, J. Iran. Chem. Soc., 14, 1651, 10.1007/s13738-017-1105-1 · doi:10.1007/s13738-017-1105-1

Cited by

See all 146

Metadata

Authors
Tamiji, T., & Nezamzadeh-Ejhieh, A.
Venue
Journal of Electroanalytical Chemistry
Publisher
Elsevier BV
Published
2018-11
Volume
829
Pages
95-105
ISSN
1572-6657 (ISSN-L)
OpenAlex
W2894858140
Cited by
146
References
0
FWCI
7.60
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II). https://app.cochat.ai/papers/10.1016/j.jelechem.2018.10.011
The paper
Tamiji, T., & Nezamzadeh-Ejhieh, A. (2018). A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II). Journal of Electroanalytical Chemistry. https://doi.org/10.1016/j.jelechem.2018.10.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.