A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II)
The DOI matches its Crossref record.
Abstract
The Sn(IV) ion exchanged clinoptilolite nanoparticles (Sn(IV)-CNP) were used as a modifier for the modification of carbon paste electrode (CPE). When the modified electrode was immersed in HCl supporting electrolyte, Sn(IV) cations can locate at the Sn(IV)-CNP-CPE electrode surface via an ion exchange process with protons of the supporting electrolyte. These electroactive cations underwent a redox process at the electrode surface. Increased peak current of Sn(IV) reduction by adding Hg(II) analyte into the supporting electrolyte solution was used for the voltammetric determination of Hg(II). Focus of the work was on study of the interaction effects between the influencing variables in square wave voltammetric response of the modified electrode in the presence of Hg(II) cations by designing the experiments (via response surface methodology: RSM) and study of some kinetic aspects of the process in linear sweep voltammetry and chronoamperometry. The optimal run in RSM was obtained in: Csn(IV) in ion exchange solution: 0.37 mol L−1, modifier%: 22.45, amplitude: 60 mV and step potential: 2.9 mV. The response current of the modified electrode was proportion to Hg(II) concentration in the range of 0.1–10 μM (DL: 0.05 μM) in square wave voltammetry and in the range of 0.1–10 μM (DL: 0.01 μM) in chronoamperometry. Using the Tafel plots, the values of α and Ko were determined for the modified electrode as 0.298, 1.91 × 10−3 s−1 and 0.311, 6.62 × 10−3 s−1 in the absence and presence of Hg(II) cations, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 61
- Eisler, 1987, Mercury hazards to fish, wildlife, and invertebrates: a synoptic review, 85, 1
- Clarkson, 1992, Mercury: major issues in environmental health, Environ. Health Perspect., 100, 31, 10.1289/ehp.9310031 · DOI
- Sigel, 1997, Metal ions in biological systems, vol. 34
- Wagner-Döbler, 2003, Pilot plant for bioremediation of mercury-containing industrial wastewater, Appl. Microbiol. Biotechnol., 62, 124, 10.1007/s00253-003-1322-7 · DOI
- Mason, 1994, The biogeochemical cycling of elemental mercury: anthropogenic influences, Geochim. Cosmochim. Acta, 58, 3191, 10.1016/0016-7037(94)90046-9 · DOI · Paper page
- Laffont, 2009, Environ. Sci. Technol., 43, 8985, 10.1021/es9019518 · doi:10.1021/es9019518
- Leopold, 2010, Methods for the determination and speciation of mercury in natural waters - a review, Anal. Chim. Acta, 663, 127, 10.1016/j.aca.2010.01.048 · DOI · Paper page
- Sideeq Bhat, 2018, Fully nozzle-jet printed non-enzymatic electrode for biosensing application, J. Colloid Interface Sci., 512, 480, 10.1016/j.jcis.2017.10.088 · doi:10.1016/j.jcis.2017.10.088
- Ehsani, 2017, Electrocatalytic oxidation of ethanol on the surface of the POAP/phosphoric acid-doped ionic liquid-functionalized graphene oxide nanocomposite film, Iran. J. Catal., 7, 187
- Zhang, 2015, 3D porous metal-organic framework as an efficient electrocatalyst for nonenzymatic sensing application, Talanta, 144, 1176, 10.1016/j.talanta.2015.07.091 · DOI
- Gervais, 2018, Study of an AuNPs functionalized electrode using different diazonium salts for the ultra-fast detection of Hg(II) traces in water, Electrochim. Acta, 261, 346, 10.1016/j.electacta.2017.12.136 · doi:10.1016/j.electacta.2017.12.136
- Zahid, 2017, A functional graphene oxide-ionic liquid composites–gold nanoparticle sensing platform for ultrasensitive electrochemical detection of Hg2+, Electrochim. Acta, 235, 72, 10.1016/j.electacta.2017.03.120 · DOI
- Kalate Bojdi, 2016, Application of a novel electrochemical sensor based on modified siliceous mesocellular foam for electrochemical detection of ultra-trace amounts of mercury ions, New J. Chem., 40, 4519, 10.1039/C5NJ02973B · doi:10.1039/c5nj02973b
- Ayranci, 2017, Rhodamine-based conjugated polymers: potentiometric, colorimetric and voltammetric sensing of mercury ions in aqueous medium, Analyst, 142, 3407, 10.1039/C7AN00606C · DOI
- Bernalte, 2011, Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes, Anal. Chim. Acta, 689, 60, 10.1016/j.aca.2011.01.042 · DOI
- Guerreiro, 2014, Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry, Anal. Chim. Acta, 810, 79, 10.1016/j.aca.2013.12.005 · DOI
- Li, 2018, Nickel oxyhydroxide-functionalized n-silicon photoelectrode for the photocurrent determination of Hg(II) ions at zero working voltage, Sensors Actuators B Chem., 257, 9, 10.1016/j.snb.2017.10.125 · doi:10.1016/j.snb.2017.10.125
- Chira, 2014, Electrode-modified with nanoparticles composed of 4,4′-bipyridine-silver coordination polymer for sensitive determination of Hg(II), Cu(II) and Pb(II), New J. Chem., 38, 5641, 10.1039/C4NJ01245C · DOI
- Damien, 1994, Tutorial review. Voltammetric determination of trace metals and organics after accumulation at modified electrodes, Analyst, 119, 1953, 10.1039/an9941901953 · doi:10.1039/an9941901953
- Lipskikh, 2018, Sensors for voltammetric determination of food azo dyes - a critical review, Electrochim. Acta, 260, 974, 10.1016/j.electacta.2017.12.027 · DOI
- Deshmukh, 2018, EDTA_PANI/SWCNTs nanocomposite modified electrode for electrochemical determination of copper (II), lead (II) and mercury (II) ions, Electrochim. Acta, 259, 930, 10.1016/j.electacta.2017.10.131 · DOI · Paper page
- Jayadevimanoranjitham, 2018, 2,4,6-Trimercaptotriazine incorporated gold nanoparticle modified electrode for anodic stripping voltammetric determination of Hg(II), Appl. Surf. Sci., 448, 444, 10.1016/j.apsusc.2018.04.096 · DOI
- Deshmukh, 2018, EDTA-modified PANI/SWNTs nanocomposite for differential pulse voltammetry based determination of Cu(II) ions, Sensors Actuators B Chem., 260, 331, 10.1016/j.snb.2017.12.160 · DOI
- N. Jeromiyas, E. Elaiyappillai, A. Senthil Kumar, Sh.-T. Huang, V. Mani, Bismuth nanoparticles decorated graphenated carbon nanotubes modified screen-printed electrode for mercury detection, J. Taiwan Inst. Chem. Eng. https://doi.org/10.1016/j.jtice.2018.08.030. · DOI
- Md Isa, 2017, Chloroplatinum(II) complex-modified MWCNTs paste electrode for electrochemical determination of mercury in skin lightening cosmetics, Electrochim. Acta, 253, 463, 10.1016/j.electacta.2017.09.092 · DOI
- Sahoo, 2015, Solvothermal synthesis of reduced graphene oxide/Au nanocomposite-modified electrode for the determination of inorganic mercury and electrochemical oxidation of toxic phenolic compounds, Electrochim. Acta, 180, 1023, 10.1016/j.electacta.2015.09.018 · doi:10.1016/j.electacta.2015.09.018
- Zhang, 2016, One-step fabrication of electrochemical biosensor based on DNA-modified three-dimensional reduced graphene oxide and chitosan nanocomposite for highly sensitive detection of Hg(II), Sensors Actuators B Chem., 225, 453, 10.1016/j.snb.2015.11.091 · DOI
- Zuo, 2016, Poly(3,4-ethylenedioxythiophene) nanorods/graphene oxide nanocomposite as a new electrode material for the selective electrochemical detection of mercury (II), Synth. Met., 220, 14, 10.1016/j.synthmet.2016.05.022 · doi:10.1016/j.synthmet.2016.05.022
- Daniel Arulraj, 2016, Femtomolar detection of mercuric ions using polypyrrole, pectin and graphene nanocomposites modified electrode, J. Colloid Interface Sci., 483, 268, 10.1016/j.jcis.2016.08.026 · doi:10.1016/j.jcis.2016.08.026
- Zuo, 2017, Utilization of AuNPs dotted S-doped carbon nanoflakes as electrochemical sensing platform for simultaneous determination of Cu (II) and Hg (II), J. Electroanal. Chem., 794, 71, 10.1016/j.jelechem.2017.04.002 · DOI
- Palanisamy, 2017, Synthesis and characterization of polypyrrole decoratedgraphene/-cyclodextrin composite for low level electrochemicaldetection of mercury (II) in water, Sensors Actuators B, 243, 888, 10.1016/j.snb.2016.12.068 · doi:10.1016/j.snb.2016.12.068
- Gumpu, 2017, Simultaneous electrochemical detection of Cd(II), Pb(II), As(III) and Hg(II) ions using ruthenium(II)-textured graphene oxide nanocomposite, Talanta, 162, 574, 10.1016/j.talanta.2016.10.076 · DOI
- Walcarius, 2008, Electroanalytical applications of microporous zeolites and mesoporous (Organo) Silicas: recent trends, Electroanalysis, 20, 711, 10.1002/elan.200704144 · DOI
- Kaur, 2015, Ultratrace detection of toxic heavy metal ions found in water bodies using hydroxyapatite supported nanocrystalline ZSM-5 modified electrodes, New J. Chem., 39, 5137, 10.1039/C4NJ02369B · DOI
- Rolison, 1990, Zeolite-modified electrodes and electrode-modified zeolites, Chem. Rev., 90, 867, 10.1021/cr00103a011 · doi:10.1021/cr00103a011
- Daas, 2016, Fuel cell applications of chemically synthesized zeolite modified electrode (ZME) as catalyst for alcohol electro-oxidation - a review, J. Electroanal. Chem., 783, 308, 10.1016/j.jelechem.2016.11.004 · doi:10.1016/j.jelechem.2016.11.004
- Walcarius, 1999, Zeolite-modified electrodes in electroanalytical chemistry, Anal. Chim. Acta, 384, 1, 10.1016/S0003-2670(98)00849-6 · DOI
- Kaur, 2015, Synthesis of NiCo2O4/Nano-ZSM-5 nanocomposite material with enhanced electrochemical properties for the simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan, New J. Chem., 39, 1115, 10.1039/C4NJ01360C · DOI
- Hosseini, 2017, Photocatalytic degradation of rhodamine B by nano bismuth oxide: process modeling by response surface methodology (RSM), Iranian J. Catal., 7, 37
- Arabpour, 2016, Photodegradation of cotrimaxazole by clinoptilolite-supported nickel oxide, Process. Saf. Environ. Prot., 102, 431, 10.1016/j.psep.2016.04.025 · doi:10.1016/j.psep.2016.04.025
- Aghdasi, 2016, Photocatalytic degradation of ciprofloxacin in the presence of synthesized ZnO nanocatalyst: the effect of operational parameters, Iran. J. Catal., 6, 481
- Amiri, 2015, Improvement of the photocatalytic activity of cupric oxide by deposition onto a natural clinoptilolite substrate, Mater. Sci. Semicond. Process., 31, 501, 10.1016/j.mssp.2014.12.030 · doi:10.1016/j.mssp.2014.12.030
- Nezamzadeh-Ejhieh, 2011, Heterogeneous photocatalytic degradation of furfural using NiS-clinoptilolite zeolite, Desalination, 273, 248, 10.1016/j.desal.2010.12.031 · DOI
- Nezamzadeh-Ejhieh, 2013, Modification of clinoptilolite nano-particles with hexadecylpyridynium bromide surfactant as an active component of Cr(VI) selective electrode, J. Ind. Eng. Chem., 19, 2026, 10.1016/j.jiec.2013.03.018 · doi:10.1016/j.jiec.2013.03.018
- Brubaker, 1955, The hydrolysis of tin(1V) in sulfuric acid, J. Am. Chem. Soc., 77, 5265, 10.1021/ja01625a013 · doi:10.1021/ja01625a013
- Karimi Shervedani, 2009, Electrochemical impedance spectroscopy as a transduction method for electrochemical recognition of zirconium on gold electrode modified with hydroxamated self-assembled monolayer, Sensors Actuators B, 139, 657, 10.1016/j.snb.2009.03.060 · doi:10.1016/j.snb.2009.03.060
- Velasco, 1997, Determination of standard rate constants for electrochemical irreversible processes from linear sweep voltammograms, Electroanalysis, 9, 880, 10.1002/elan.1140091116 · DOI
- Xu, 2009, Colorimetric detection of mercury ion (Hg2+) based on DNA oligonucleotides and unmodified gold nanoparticles sensing system with a tunable detection range, Biosens. Bioelectron., 24, 3153, 10.1016/j.bios.2009.03.025 · DOI · Paper page
- Liu, 2010, Gold nanoparticle-based colorimetric and “turn-on” fluorescent probe for mercury(II) ions in aqueous solution, Anal. Chem., 82, 9021
- Lee, 2007, Colorimetric detection of mercuric ion (Hg2+) in aqueous media using DNA-functionalized gold nanoparticles, Angew. Chem., 119, 4171, 10.1002/ange.200700269 · DOI · Paper page
- Guo, 2017, Determination of Hg2+ based on the selective enhancement of peroxidase mimetic activity of hollow porous gold nanoparticles, Nano, 12, 10.1142/S1793292017500503 · doi:10.1142/s1793292017500503
- Kim, 2007, Ratiometric determination of Hg2+ ions based on simple molecular motifs of pyrene and dioxaoctanediamide, Org. Lett., 9, 1129, 10.1021/ol070143r · doi:10.1021/ol070143r
- Lu, 2003, Voltammetric determination of mercury (II) in aqueous media using glassy carbon electrodes modified with novel Cali x[4]arene, Talanta, 59, 553, 10.1016/S0039-9140(02)00569-6 · doi:10.1016/s0039-9140(02)00569-6
- Wang, 2010, Colorimetric biosensing of mercury(II) ion using unmodified gold nanoparticleprobes and thrombin-binding aptamer, Biosens. Bioelectron., 25, 1994, 10.1016/j.bios.2010.01.014 · DOI · Paper page
- Gan, 1997, Copolymers of N-acryloyl-N'-metbylpiperazine and methyl methylacrylate were synthesized and its application for Hg(II) detection by anodic striping voltammetry, Eur. Polym. J., 33, 615, 10.1016/S0014-3057(96)00227-3 · doi:10.1016/s0014-3057(96)00227-3
- Nascimento, 2012, Complexation of Hg(II) by humic acid studied by square wave stripping voltammetry at screen-printed gold electrodes, Talanta, 100, 57, 10.1016/j.talanta.2012.08.018 · doi:10.1016/j.talanta.2012.08.018
- Hezard, 2012, Gold nanoparticles electrodeposited on glassy carbon using cyclic voltammetry: application to Hg(II) trace analysis, J. Electroanal. Chem., 664, 46, 10.1016/j.jelechem.2011.10.014 · DOI · Paper page
- Han, 2009, A regenerative electrochemical sensor based on oligonucleotide for the selective determination of mercury(II), Analyst, 134, 1857, 10.1039/b908457f · DOI
- Lahrich, 2016, Catalytic effect of potassium in Na1-xKxCdPb3(PO4)3 to detect mercury (II) in fish and seawater using a carbon paste electrode, Talanta, 149, 158, 10.1016/j.talanta.2015.11.055 · DOI
- Xing, 2016, Highly sensitive simultaneous determination of cadmium (II), lead (II), copper (II), and mercury (II) ions on N-doped graphene modified electrode, J. Electroanal. Chem., 760, 52, 10.1016/j.jelechem.2015.11.043 · DOI
- Ozkorucuklu, 2017, Voltammetric determination of mercury(II) using a modified pencil graphite electrode with 4-(4-methylphenyl amino iso-nitrosoacetyl) biphenyl, J. Iran. Chem. Soc., 14, 1651, 10.1007/s13738-017-1105-1 · doi:10.1007/s13738-017-1105-1
Cited by
The stability of MOFs in aqueous solutions—research progress and prospects
An, Y., Lv, X., Jiang, W., Wang, L., Shi, Y., Hang, X., & Pang, H. (2024) · Green Chemical Engineering · doi:10.1016/j.gce.2023.07.004 · Cited by 311
Lead and cadmium clean removal from wastewater by sustainable biochar derived from poplar saw dust
Cheng, S., Liu, Y., Xing, B., Qin, X., Zhang, C., & Xia, H. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.128074 · Cited by 255
Abdelrahman, E. A., Abou El-Reash, Y. G., Youssef, H. M., Kotp, Y. H., & Hegazey, R. M. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123813 · Cited by 174
Liu, R., Zhang, Y., Hu, B., & Wang, H. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2021.132087 · Cited by 104
Miądlicki, P., Wróblewska, A., Kiełbasa, K., Koren, Z. C., & Michalkiewicz, B. (2021) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2021.111266 · Cited by 47
Metadata
- Authors
- Tamiji, T., & Nezamzadeh-Ejhieh, A.
- Venue
- Journal of Electroanalytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 829
- Pages
- 95-105
- ISSN
- 1572-6657 (ISSN-L)
- OpenAlex
- W2894858140
- Cited by
- 146
- References
- 0
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II). https://app.cochat.ai/papers/10.1016/j.jelechem.2018.10.011
- The paper
- Tamiji, T., & Nezamzadeh-Ejhieh, A. (2018). A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II). Journal of Electroanalytical Chemistry. https://doi.org/10.1016/j.jelechem.2018.10.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.