Cited by 8Patient Safety and Medication ErrorsPharmacy and Medical PracticesElectronic Health Records Systems

Automated Dispensing Cabinet Overrides—An Evaluation of Necessity in a Pediatric Emergency Department

Paterson, Erica P., Manning, Kennedy B., Schmidt, Matthew D., Provine, Allison D.·2022·Journal of Emergency Nursing

Abstract

Objective Automated dispensing cabinets, or ADCs, are often used at health care facilities to aid in the medication-use process. Although ADCs minimize certain medication errors, they introduce a new type of error involving overrides. Although helpful when used appropriately in emergencies, overrides bypass pharmacist verification and increase potential for patient harm through drug-drug interactions, medication allergies, inappropriate dosing, and more. The purpose of this study was to evaluate automated dispensing cabinets override pulls in a pediatric hospital's emergency department. The authors sought to discover whether overridden medications were being administered before verification (indicating it was needed emergently, thus justifying override) or after verification (indicating the override did not result in quicker administration and/or the medication was not emergent). Methods This was a retrospective, observational study. Data were collected from electronic health record reports from a 343-bed pediatric hospital's emergency department from October 13, 2019, to December 22, 2019. Results A total of 445 override pulls were identified during this time, and after data analysis, 99 override pulls remained in the data set. Overall, time from input of prescription into the electronic medical record to medication override was approximately 4 minutes. Pharmacist verification also took a median of four minutes after prescription input. However, administration took twice as…

Integrity signals

Registry

Crossref · 10.1016/j.jen.2022.01.007

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Paterson, E. P., Manning, K. B., Schmidt, M. D., & Provine, A. D.
Venue
Journal of Emergency Nursing
Publisher
Elsevier BV
Published
2022-05
Volume
48
Issue
3
Pages
319-327
ISSN
0099-1767 (ISSN-L)
OpenAlex
W4229012452
Cited by
8
References
0
Citations by year
2026: 3 · 2025: 2 · 2024: 3
FWCI
1.47
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Emergency Nursing (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Pharmacy and Medical Practices
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
Keywords
automated dispensing cabinets, medication errors, medication administration, pediatric emergency department, drug safety, drug-drug interactions, drug hypersensitivity, inappropriate dosing
MeSH terms
Child, Pharmaceutical Preparations, Emergency Service, Hospital, Humans, Medication Errors, Medication Systems, Hospital, Pharmacists, Retrospective Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review