The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Support vector machine based fault classification and location of a long transmission line
Open accessAbstract
This paper investigates support vector machine based fault type and distance estimation scheme in a long transmission line. The planned technique uses post fault single cycle current waveform and pre-processing of the samples is done by wavelet packet transform. Energy and entropy are obtained from the decomposed coefficients and feature matrix is prepared. Then the redundant features from the matrix are taken out by the forward feature selection method and normalized. Test and train data are developed by taking into consideration variables of a simulation situation like fault type, resistance path, inception angle, and distance. In this paper 10 different types of short circuit fault are analyzed. The test data are examined by support vector machine whose parameters are optimized by particle swarm optimization method. The anticipated method is checked on a 400 kV, 300 km long transmission line with voltage source at both the ends. Two cases were examined with the proposed method. The first one is fault very near to both the source end (front and rear) and the second one is support vector machine with and without optimized parameter. Simulation result indicates that the anticipated method for fault classification gives high accuracy (99.21%) and least fault distance estimation error (<0.21%) for all discussed cases. In order to verify the accuracy of the proposed method, a comparison is carried out with methods published by other researchers. Separate investigation is also carried out with the transmission line placing thyristor controlled series capacitor in the middle and applying the same proposed method. It is observed from the test results of the thyristor controlled series capacitor based transmission line model that fault classification gives a high accuracy of 98.36% and absolute fault location error is >0.29%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635
Cited by
Gururajapathy, S. S., Mokhlis, H., & Illias, H. A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.021 · Cited by 360
Chen, Y. Q., Fink, O., & Sansavini, G. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2721922 · Cited by 258
Metadata
- Authors
- Ray, P., & Mishra, D. P.
- Venue
- Engineering Science and Technology, an International Journal
- Publisher
- Elsevier BV
- Published
- 2016-09
- Volume
- 19
- Issue
- 3
- Pages
- 1368-1380
- ISSN
- 2215-0986 (ISSN-L)
- OpenAlex
- W2339065801
- Cited by
- 181
- References
- 1
- FWCI
- 11.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Support vector machine based fault classification and location of a long transmission line. https://app.cochat.ai/papers/10.1016/j.jestch.2016.04.001
- The paper
- Ray, P., & Mishra, D. P. (2016). Support vector machine based fault classification and location of a long transmission line. Engineering Science and Technology, an International Journal. https://doi.org/10.1016/j.jestch.2016.04.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.