The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A modified methylene blue assay for accurate cell counting
Open accessAbstract
Cell counting is a common technique in cellular and molecular biology research applications, such as cell culture maintenance, cell plating, cell growth and cell doubling time determinations, as well as cell proliferation and cytotoxicity measurements. Many commonly employed cell counting methods exhibit limitations that influence resulting accuracy or versatility. For example, the trypan blue method typically underestimates cell numbers in culture, and the Lowry protein assay can be influenced by cell cycle. An urgent need exists for a method of cell counting that is both accurate and versatile. This work intended to explore an adaptation of the methylene blue assay to overcome the existing limitations of the procedure, enabling application to a broader range of cell densities and various cell culture plates. This new methylene blue assay was found to be more efficient, accurate and sensitive. A linear relationship (r2 > 0.99) was established between cell number and absorbance at 570 nm wavelength when the new methylene blue assay was applied to three cell lines (HepG2, Caco-2, and MCF-7) plated in a broad range of cell densities (5 × 104 to 2.5 × 106) in four different types of culture plates (6-, 12-, 24-, and 96-well plates). Growth curves were determined using both the trypan blue and methylene blue methods. At each time point in the HepG2 growth curve, the cell count obtained using the trypan blue assay was statistically significantly lower than that obtained using the methylene blue assay (p < 0.05). The same was true for the Caco-2 growth curve at all time points (p < 0.05) except at the 0 h. The methylene blue method proposed in this paper may serve as a direct, automated counting method for cells grown in any type of culture plates. This assay has clear advantages over traditional methods and is a powerful tool for any application requiring a versatile, efficient, and accurate method of cell counting, such as bioavailability and cytotoxicity assays, and more basic experiments such as cell growth curve or doubling time determination, especially in the research of natural products, bioactive compounds, phytochemicals, functional foods and nutraceuticals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How Proteolysis Drives the Cell Cycle
King, R. W., Deshaies, R. J., Peters, J.-M., & Kirschner, M. W. (1996) · Science · doi:10.1126/science.274.5293.1652 · Cited by 1,273
Antioxidant and Antiproliferative Activities of Common Vegetables
Chu, Y.-F., Sun, J., Wu, X., & Liu, R. H. (2002) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf020665f · Cited by 937
Self-citation
Cited by
Phytochemical Profiles and Antioxidant Activity of Adlay Varieties
Wang, L., Chen, J., Xie, H., Ju, X., & Liu, R. H. (2013) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf400556s · Cited by 481
Self-citationCellular Antioxidant Activity of Common Vegetables
Song, W., Derito, C. M., Liu, M. K., He, X., Dong, M., & Liu, R. H. (2010) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf9035832 · Cited by 283
Self-citation
Metadata
- Authors
- Felice, D. L., Sun, J., & Liu, R. H.
- Venue
- Journal of Functional Foods
- Publisher
- Elsevier BV
- Published
- 2009-01
- Volume
- 1
- Issue
- 1
- Pages
- 109-118
- ISSN
- 1756-4646 (ISSN-L)
- OpenAlex
- W2037818656
- Cited by
- 170
- References
- 2
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A modified methylene blue assay for accurate cell counting. https://app.cochat.ai/papers/10.1016/j.jff.2008.09.014
- The paper
- Felice, D. L., Sun, J., & Liu, R. H. (2009). A modified methylene blue assay for accurate cell counting. Journal of Functional Foods. https://doi.org/10.1016/j.jff.2008.09.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.