CoChat

Multiplex SERS-based lateral flow immunosensor for the detection of major mycotoxins in maize utilizing dual Raman labels and triple test lines

Zhang, Wanjun, Tang, Shusheng, Jin, Yongpeng, Yang, Chunjiang, He, Lidong, Wang, Jiayi, Chen, Yiqiang · 2020 · Journal of Hazardous Materials
Cited by 195

The DOI matches its Crossref record.

Abstract

A multiplex surface-enhanced Raman scattering (SERS)-based lateral flow immunosensor was developed to determine six major mycotoxins in maize. Two characteristic Raman reporter molecules-5,5-dithiobis-2-nitrobenzoic acid (DTNB) and 4-mercaptobenzoic acid (MBA)-were used to label the synthesized Au@Ag core-shell nanoparticles for the preparation of SERS nanoprobes as detection reagents. Six corresponding hapten-protein conjugates were prepared and dispensed on three test lines of nitrocellulose membrane with two conjugates on each line as capture antigens. This design facilitates the simultaneous detection of the six mycotoxins in a single test. After optimizing the experimental parameters of immunosensor, the limits of detection were as low as 0.96 pg/mL for aflatoxin B1, 6.2 pg/mL for zearalenone, 0.26 ng/mL for fumonisin B1, 0.11 ng/mL for deoxynivalenol, 15.7 pg/mL for ochratoxin A, and 8.6 pg/mL for T-2 toxin, respectively. The spiking experiment showed high accuracy with recovery of 78.9-106.2 % and satisfactory assay precision with the coefficient of variations below 16 %. Moreover, this assay can be completed in less than 20 min, and its detection results were consistent with that of liquid chromatography-mass spectrometry. Therefore, the developed SERS-based lateral flow immunosensor is a promising approach for mycotoxin detection in the field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jhazmat.2020.122348

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
Zhang, W., Tang, S., Jin, Y., Yang, C., He, L., Wang, J., & Chen, Y.
Venue
Journal of Hazardous Materials
Publisher
Elsevier BV
Published
2020-07
Volume
393
Pages
122348
ISSN
0304-3894 (ISSN-L)
OpenAlex
W3008665751
Cited by
195
References
0
FWCI
8.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplex SERS-based lateral flow immunosensor for the detection of major mycotoxins in maize utilizing dual Raman labels and triple test lines. https://app.cochat.ai/papers/10.1016/j.jhazmat.2020.122348
The paper
Zhang, W., Tang, S., Jin, Y., Yang, C., He, L., Wang, J., & Chen, Y. (2020). Multiplex SERS-based lateral flow immunosensor for the detection of major mycotoxins in maize utilizing dual Raman labels and triple test lines. Journal of Hazardous Materials. https://doi.org/10.1016/j.jhazmat.2020.122348

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.