Nafion-stabilized two-dimensional transition metal carbide (Ti3C2Tx MXene) as a high-performance electrochemical sensor for neurotransmitter
Abstract
Abstract Herein, we demonstrate the selective sensing of Dopamine (DA), an important neurotransmitter, by using Nafion-stabilized two-dimensional transition metal carbides (Ti3C2Tx MXenes). Ti3C2Tx was deposited on a glassy carbon electrode followed by Nafion coating to achieve a robust sensitivity (∼3 nM), good selectivity, wide detection window (0.015–10 μM), high stability, reproducibility, and outstanding recoveries for DA detection in real samples. MXene-based biosensor exhibited much better electrochemical performance when compared with reduced graphene oxide-based biosensor under similar experimental conditions due to the MXenes good electrical conductivity and negatively charged surface which assisted in the selective and sensitive detection of DA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A cellular mechanism of reward-related learning
Reynolds, J. N. J., Hyland, B. I., & Wickens, J. R. (2001) · Nature · doi:10.1038/35092560 · Cited by 879
Cited by
Ti3C2TX MXene for Sensing Applications: Recent Progress, Design Principles, and Future Perspectives
Pei, Y., Zhang, X., Hui, Z., Zhou, J., Huang, X., Sun, G., & Huang, W. (2021) · ACS Nano · doi:10.1021/acsnano.1c00248 · Cited by 799
Sensing with MXenes: Progress and Prospects
Ho, D. H., Choi, Y. Y., Jo, S. B., Myoung, J., & Cho, J. H. (2021) · Advanced Materials · doi:10.1002/adma.202005846 · Cited by 482
2D Transition Metal Carbides (MXenes): Applications as an Electrically Conducting Material
Shahzad, F., Iqbal, A., Kim, H., & Koo, C. M. (2020) · Advanced Materials · doi:10.1002/adma.202002159 · Cited by 451
Self-citationSurface functionalization of MXenes
Mozafari, M., & Soroush, M. (2021) · Materials Advances · doi:10.1039/d1ma00625h · Cited by 395
Chaudhary, V., Kaushik, A., Furukawa, H., & Khosla, A. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac5ac6 · Cited by 386
Metadata
- Authors
- Shahzad, F., Iqbal, A., Zaidi, S. A., Hwang, S.-W., & Koo, C. M.
- Venue
- Journal of Industrial and Engineering Chemistry
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 79
- Pages
- 338-344
- ISSN
- 1226-086X (ISSN-L)
- OpenAlex
- W2962334491
- Cited by
- 168
- References
- 1
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nafion-stabilized two-dimensional transition metal carbide (Ti3C2Tx MXene) as a high-performance electrochemical sensor for neurotransmitter. https://app.cochat.ai/papers/10.1016/j.jiec.2019.03.061
- The paper
- Shahzad, F., Iqbal, A., Zaidi, S. A., Hwang, S.-W., & Koo, C. M. (2019). Nafion-stabilized two-dimensional transition metal carbide (Ti3C2Tx MXene) as a high-performance electrochemical sensor for neurotransmitter. Journal of Industrial and Engineering Chemistry. https://doi.org/10.1016/j.jiec.2019.03.061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.