Deep eutectic solvents synthesis of perovskite type cerium aluminate embedded carbon nitride catalyst: High-sensitive amperometric platform for sensing of glucose in biological fluids
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
By ultrasonic mixing, perovskite-type CeAlO3 was combined with CN to form the CeAlO3@CN composite, which is then deposited on a glass carbon electrode.
“By ultrasonic mixing, perovskite-type CeAlO 3 was combined with CN to form the CeAlO 3 @CN composite, which is then deposited on a glass carbon electrode (Figure 12C) [187].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [187]
Tested in an electrochemical three-electrode system, this material demonstrated a linear concentration range for glucose detection of 0.01-1034.5 μM, with a detection limit of 0.86 nM.
“Tested in an electrochemical three-electrode system, this material demonstrated a linear concentration range for glucose detection of 0.01-1034.5µM, with a detection limit of 0.86 nM.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [187]
Comparisons of glucose measurements in human blood, saliva, and sweat revealed results consistent with commercial glucose meters, with an error of less than 5%.
“Comparisons of glucose measurements in human blood, saliva, and sweat revealed results consistent with commercial glucose meters, with an error of less than 5% [187].”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [187]
Cited by
Sorted by citations
Design Strategies and Emerging Applications of Perovskite-Based Sensors
Li, Y., Ding, Y., Sun, J., Tan, S., Li, Y., Wang, X., Cai, J., Bai, J., Lv, X., Guo, W., et al. (2025) · SmartMat · doi:10.1002/smm2.70022 · Cited by 41 · see citing works
“…material demonstrated a linear concentration range for glucose detection of 0.01 – 1034.5 µM, with a detection limit of 0.86 nM. Comparisons of glucose measurements in human blood, saliva, and sweat revealed results consistent with commercial glucose meters, with an error of less than 5% [187].”
InfluentialPiñón-Balderrama, C. I., Leyva-Porras, C., Conejo-Dávila, A. S., Estrada-Monje, A., Maldonado-Orozco, M. C., Reyes-López, S. Y., & Zaragoza-Contreras, E. A. (2023) · Chemosensors · doi:10.3390/chemosensors11090507 · Cited by 16 · see citing works
- Authors
- Rajaji, U., Ganesh, P.-S., Chen, S.-M., Govindasamy, M., Kim, S.-Y., A. Alshgari, R., & Shimoga, G.
- Affiliations
- National Taipei University of Technology (TW)
- Korea University of Technology and Education (KR)
- Corresponding author
- Chen, Shen-Ming
- Kim, Sang-Youn
- ORCID
- Venue
- Journal of Industrial and Engineering Chemistry
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 102
- Pages
- 312-320
- ISSN
- 1226-086X (ISSN-L)
- OpenAlex
- W3183541170
- Cited by
- 42
- References
- 0
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 7 · 2023: 15 · 2022: 10 · 2021: 4
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Industrial and Engineering Chemistry (publishedVersion)
- Funders
- Institute for Information and Communications Technology Promotion
- King Saud University
- KOREATECH (NRF-2020R1I1A3065371)
- Ministry of Science, ICT and Future Planning (2020-0-00594)
- National Research Foundation of Korea
- Ministry of Education
- National Taipei Institute of Technology
- Ministry of Science and Technology, Taiwan (108-2113-M-027-005-MY3)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Electrocatalysts for Energy Conversion
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- deep eutectic solvents, CeAlO3, carbon nitride, non-enzymatic glucose sensor, glucose oxidation, electrocatalysts, amperometric detection, modified glassy carbon electrode, pyridinic nitrogen, pyrrolic nitrogen, graphitic nitrogen, hydrothermal synthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›