The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Development and validation of a homogeneous mobility shift assay for the measurement of infliximab and antibodies-to-infliximab levels in patient serum
Open accessAbstract
Antibody-based drugs such as infliximab (IFX) are effective for the treatment of inflammatory bowel disease (IBD) and other immune-mediated disorders. The development of antibodies against these drugs may result in unfavorable consequences, including the loss of drug efficacy, hypersensitivity reactions, and other adverse events. Therefore, accurate monitoring of serum drug and anti-drug antibody levels should be an important part of therapy for patients being treated with an antibody-based drug. Current methods for the assessment of anti-drug antibodies and drug levels, involving various bridging ELISA and radioimmunoassay techniques, are limited by their sensitivity, interference, and/or complexity. To overcome these limitations, we have developed a non-radiolabeled homogeneous mobility shift assay (HMSA) to measure the antibodies-to-infliximab (ATI) and IFX levels in serum samples. Full method validation was performed on both the ATI- and IFX-HMSA, and the clinical sample test results were also compared with those obtained from a bridging ELISA method to evaluate the difference in performance between the two assays. Validation of the ATI-HMSA revealed a lower limit of quantitation of 0.012 μg/mL in serum. The linear range of quantitation was 0.029-0.54 μg/mL. The intra- and inter-assay precision was less than 20% of coefficient of variation (CV), and the accuracy (% error) of the assay was less than 20%. In serum samples, ATI as low as 0.036 μg/mL can be measured, even in the presence of 60 μg/mL of IFX in the serum. Sera from 100 healthy subjects were tested to determine the cut point of the assay. ATI-positive samples that had been previously analyzed by using a bridging ELISA from 100 patients were also measured by the new method. There was a high correlation between the two methods for ATI levels (p<0.001). Significantly, the new method identified five false-positive samples from the bridging ELISA method. Validation of the mobility shift IFX assay also showed high assay sensitivity, precision and accuracy. The HMSA method may also be applied to other protein-based drugs to accurately detect serum drug and anti-drug antibody levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targan, S. R., Hanauer, S. B., van Deventer, S. J. H., Mayer, L., Present, D. H., Braakman, T., DeWoody, K. L., Schaible, T. F., & Rutgeerts, P. J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199710093371502 · Cited by 3,135
Safety and immunotoxicity assessment of immunomodulatory monoclonal antibodies
Brennan, F. R., Morton, L. D., Spindeldreher, S., Kiessling, A., Allenspach, R., Hey, A., Müller, P., Frings, W., & Sims, J. (2010) · mAbs · doi:10.4161/mabs.2.3.11782 · Cited by 250
Svenson, M., Geborek, P., Saxne, T., & Bendtzen, K. (2007) · Rheumatology · doi:10.1093/rheumatology/kem261 · Cited by 189
Cited by
Yarur, A. J., Kanagala, V., Stein, D. J., Czul, F., Quintero, M. A., Agrawal, D., Patel, A., Best, K., Fox, C., Idstein, K., et al. (2017) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.13970 · Cited by 308
Mitrev, N., Vande Casteele, N., Seow, C. H., Andrews, J. M., Connor, S. J., Moore, G. T., Barclay, M., Begun, J., Bryant, R., Chan, W., et al. (2017) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.14368 · Cited by 282
Bendtzen, K. (2015) · Frontiers in Immunology · doi:10.3389/fimmu.2015.00109 · Cited by 73
Metadata
- Authors
- Wang, S.-L., Ohrmund, L., Hauenstein, S., Salbato, J., Reddy, R., Monk, P., Lockton, S., Ling, N., & Singh, S.
- Venue
- Journal of Immunological Methods
- Publisher
- Elsevier BV
- Published
- 2012-08
- Volume
- 382
- Issue
- 1-2
- Pages
- 177-188
- ISSN
- 0022-1759 (ISSN-L)
- OpenAlex
- W2059843231
- Cited by
- 208
- References
- 3
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and validation of a homogeneous mobility shift assay for the measurement of infliximab and antibodies-to-infliximab levels in patient serum. https://app.cochat.ai/papers/10.1016/j.jim.2012.06.002
- The paper
- Wang, S.-L., Ohrmund, L., Hauenstein, S., Salbato, J., Reddy, R., Monk, P., Lockton, S., Ling, N., & Singh, S. (2012). Development and validation of a homogeneous mobility shift assay for the measurement of infliximab and antibodies-to-infliximab levels in patient serum. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2012.06.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.