Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples
Open accessThe DOI matches its Crossref record.
Abstract
Despite the widespread use of multiplex immunoassays, there are very few scientific reports that test the accuracy and reliability of a platform prior to publication of experimental data. Our laboratory has previously demonstrated the need for new assay platform validation prior to use of biologic samples from large studies in order to optimize sample handling and assay performance. In this study, our goal was to test the accuracy and reproducibility of an electrochemiluminescent multiplex immunoassay platform (Meso Scale Discovery, MSD®) and compare this platform to validated, singleplex immunoassays (R&D Systems®) using actual study subject (human plasma and mouse bronchoalveolar lavage fluid (BALF) and plasma) samples. We found that the MSD platform performed well on intra- and inter-assay comparisons, spike and recovery and cross-platform comparisons. The mean intra-assay CV% and range for MSD was 3.49 (0.0-10.4) for IL-6 and 2.04 (0.1-7.9) for IL-8. The correlation between values for identical samples measured on both MSD and R&D was R=0.97 for both analytes. The mouse MSD assay had a broader range of CV% with means ranging from 9.5-28.5 depending on the analyte. The range of mean CV% was similar for single plex ELISAs at 4.3-23.7 depending on the analyte. Regardless of species or sample type, CV% was more variable at lower protein concentrations. In conclusion, we validated a multiplex electrochemiluminscent assay system and found that it has superior test characteristics in human plasma compared to mouse BALF and plasma. Both human and MSD assays compared favorably to well-validated singleplex ELISA's
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EAACI Molecular Allergology User's Guide
Matricardi, P. M., Kleine‐Tebbe, J., Hoffmann, H. J., Valenta, R., Hilger, C., Hofmaier, S., Aalberse, R. C., Agache, I., Asero, R., Ballmer‐Weber, B., et al. (2016) · Pediatric Allergy and Immunology · doi:10.1111/pai.12563 · Cited by 932
“E A different multiarray approach has been employed byMesoScale Discovery (93).”
MethodELISA in the multiplex era: Potentials and pitfalls
Tighe, P. J., Ryder, R. R., Todd, I., & Fairclough, L. C. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400130 · Cited by 464
EAACI Molecular Allergology User's Guide 2.0
Dramburg, S., Hilger, C., Santos, A. F., de las Vecillas, L., Aalberse, R. C., Acevedo, N., Aglas, L., Altmann, F., Arruda, K. L., Asero, R., et al. (2023) · Pediatric Allergy and Immunology · doi:10.1111/pai.13854 · Cited by 298
Koelman, L., Pivovarova-Ramich, O., Pfeiffer, A. F. H., Grune, T., & Aleksandrova, K. (2019) · Immunity & Ageing · doi:10.1186/s12979-019-0151-1 · Cited by 177
Barhoum, A., Altintas, Z., Devi, K. S. S., & Forster, R. J. (2023) · Nano Today · doi:10.1016/j.nantod.2023.101874 · Cited by 176
Metadata
- Authors
- Bastarache, J. A., Koyama, T., Wickersham, N. E., & Ware, L. B.
- Venue
- Journal of Immunological Methods
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 408
- Pages
- 13-23
- ISSN
- 0022-1759 (ISSN-L)
- OpenAlex
- W2092612405
- Cited by
- 72
- References
- 0
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples. https://app.cochat.ai/papers/10.1016/j.jim.2014.04.006
- The paper
- Bastarache, J. A., Koyama, T., Wickersham, N. E., & Ware, L. B. (2014). Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2014.04.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.