The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Laser cladding of Inconel 625 wire for corrosion protection
Open accessAbstract
The electrochemical corrosion performance of laser clad Inconel 625 wire in a de-aerated 3.5 wt% NaCl solution was investigated. The microstructure of the clad beads before and after the corrosion testing was examined using a combination of optical microscopy, scanning electron microscopy (with energy dispersive X-ray analysis) and X-ray diffraction. Well bonded, minimally diluted, pore- and crack-free single bead and multiple (overlapped) beads of Inconel 625 wire were successfully deposited. The clad beads comprise dendritic γ-Ni (FCC) matrix and interdendritic precipitates which are Mo- and Nb-rich. The microstructural evolution of a typical clad bead is observed to begin with columnar dendrites, at the clad-substrate interface, growing vertically to the substrate. This blends into horizontal columnar dendrites near the top region. High integrity laser coating (multiple beads) of Inconel 625 wire with a minimal dilution ratio of 4.5% is found in this study. The corrosion performance of the coating, which degrades with increasing Fe dilution, is very close to that of wrought Inconel 625 but superior to the wrought 304L stainless steel. The stainless steel exhibited localised (pitting) corrosion however, it was fully protected by the Inconel 625 wire laser coating in the saline solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Superalloys: A Technical Guide
Donachie, M. J., & Donachie, S. J. (2002) · Cited by 1,160
Dinda, G. P., Dasgupta, A. K., & Mazumder, J. (2009) · Materials Science and Engineering: A · doi:10.1016/j.msea.2009.01.009 · Cited by 858
Investigating laser rapid manufacturing for Inconel-625 components
Paul, C. P., Ganesh, P., Mishra, S. K., Bhargava, P., Negi, J., & Nath, A. K. (2007) · Optics & Laser Technology · doi:10.1016/j.optlastec.2006.01.008 · Cited by 274
Laser metal deposition of Inconel 625: Microstructure and mechanical properties
Rombouts, M., Maes, G., Mertens, M., & Hendrix, W. (2012) · Journal of Laser Applications · doi:10.2351/1.4757717 · Cited by 138
Al-Fadhli, H. Y., Stokes, J. T., Hashmi, M. S. J., & Yilbaş, B. S. (2005) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2005.08.143 · Cited by 97
Rajani, H. R. Z., Mousavi, S. A. A. A., & Sani, F. M. (2012) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2012.06.053 · Cited by 75
Microstructure and corrosion behavior of high power diode laser deposited Inconel 625 coatings
Tuominen, J., Vuoristo, P. M. J., Mäntylä, T., et al. (2003) · Journal of Laser Applications · doi:10.2351/1.1536652 · Cited by 33
Cited by
Olakanmi, E. O., Nyadongo, S. T., Malikongwa, K., Lawal, S. A., Botes, A., & Pityana, S. L. (2019) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2018.09.063 · Cited by 53
Metadata
- Authors
- Abioye, T. E., McCartney, D. G., & Clare, A. T.
- Venue
- Journal of Materials Processing Technology
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 217
- Pages
- 232-240
- ISSN
- 0924-0136 (ISSN-L)
- OpenAlex
- W1979067849
- Cited by
- 330
- References
- 7
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.