Tilt-Pair Analysis of Images from a Range of Different Specimens in Single-Particle Electron Cryomicroscopy
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The comparison of a pair of electron microscope images recorded at different specimen tilt angles provides a powerful approach for evaluating the quality of images, image-processing procedures, or three-dimensional structures. Here, we analyze tilt-pair images recorded from a range of specimens with different symmetries and molecular masses and show how the analysis can produce valuable information not easily obtained otherwise. We show that the accuracy of orientation determination of individual single particles depends on molecular mass, as expected theoretically since the information in each particle image increases with molecular mass. The angular uncertainty is less than 1° for particles of high molecular mass (~50 MDa), several degrees for particles in the range 1-5 MDa, and tens of degrees for particles below 1 MDa. Orientational uncertainty may be the major contributor to the effective temperature factor (B-factor) describing contrast loss and therefore the maximum resolution of a structure determination. We also made two unexpected observations. Single particles that are known to be flexible showed a wider spread in orientation accuracy, and the orientations of the largest particles examined changed by several degrees during typical low-dose exposures. Smaller particles presumably also reorient during the exposure; hence, specimen movement is a second major factor that limits resolution. Tilt pairs thus enable assessment of orientation accuracy, map quality, specimen motion, and conformational heterogeneity. A convincing tilt-pair parameter plot, where 60% of the particles show a single cluster around the expected tilt axis and tilt angle, provides confidence in a structure determined using electron cryomicroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416 · cited 6×
“The orientations were determined by pro jec t ion matching us ing the program FREALIGN(37,38) and then used to plot the change in orientation between the two images using the program Tiltdiff.(27) Tiltdiff shows the tilt angle and tilt axis required to rotate from one view of a 3D structure to another.”
MethodInfluentialSelf-citationA ratchet-like inter-subunit reorganization of the ribosome during translocation
Frank, J., & Agrawal, R. K. (2000) · Nature · doi:10.1038/35018597 · Cited by 799
Cited by
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
“see Table 2 in Henderson et al. (2011). The statistical assumptions of the MAP approach may be used to estimate the accuracy with which orientational assignments can be made for a given model.”
BackgroundMethodResultInfluentialPrevention of overfitting in cryo-EM structure determination
Scheres, S. H. W., & Chen, S. (2012) · Nature Methods · doi:10.1038/nmeth.2115 · Cited by 1,242
Self-citationChen, S., McMullan, G., Faruqi, A. R., Murshudov, G. N., Short, J. M., Scheres, S. H. W., & Henderson, R. (2013) · Ultramicroscopy · doi:10.1016/j.ultramic.2013.06.004 · Cited by 1,003
Self-citationGrant, T., & Grigorieff, N. (2015) · eLife · doi:10.7554/elife.06980 · Cited by 826
Self-citationCryo-EM Structure of a Fully Glycosylated Soluble Cleaved HIV-1 Envelope Trimer
Lyumkis, D., Julien, J.-P., de Val, N., Cupo, A., Potter, C. S., Klasse, P.-J., Burton, D. R., Sanders, R. W., Moore, J. P., Carragher, B., et al. (2013) · Science · doi:10.1126/science.1245627 · Cited by 669
Metadata
- Authors
- Henderson, R., Chen, S., Chen, J. Z., Grigorieff, N., Passmore, L. A., Ciccarelli, L., Rubinstein, J. L., Crowther, R. A., Stewart, P. L., & Rosenthal, P. B.
- Venue
- Journal of Molecular Biology
- Publisher
- Elsevier BV
- Published
- 2011-11
- Volume
- 413
- Issue
- 5
- Pages
- 1028-1046
- ISSN
- 0022-2836 (ISSN-L)
- OpenAlex
- W2102663456
- Cited by
- 155
- References
- 2
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.