The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Nanomechanics of collagen fibrils under varying cross-link densities: Atomistic and continuum studies
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lodish, H. F. (1986) · Cited by 5,650
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Structure and mechanical quality of the collagen–mineral nano-composite in bone
Fratzl, P., Gupta, H. S., Paschalis, E. P., & Roschger, P. (2004) · J. Mater. Chem. · doi:10.1039/b402005g · Cited by 1,222
How Strong Is a Covalent Bond?
Grandbois, M., Beyer, M., Rief, M., Clausen-Schaumann, H., & Gaub, H. E. (1999) · Science · doi:10.1126/science.283.5408.1727 · Cited by 1,095
Microfibrillar structure of type I collagen in situ
Orgel, J. P. R. O., Irving, T. C., Miller, A., & Wess, T. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502718103 · Cited by 930
Nature designs tough collagen: Explaining the nanostructure of collagen fibrils
Buehler, M. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0603216103 · Cited by 803
Self-citationMineralized Collagen Fibrils: A Mechanical Model with a Staggered Arrangement of Mineral Particles
Jäger, I., & Fratzl, P. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76426-5 · Cited by 793
Slack, J. M. W. (2020) · Principles of Tissue Engineering · doi:10.1016/b978-0-12-818422-6.00005-8 · Cited by 742
The virial theorem and stress calculation in molecular dynamics
Tsai, D. H. (1979) · The Journal of Chemical Physics · doi:10.1063/1.437577 · Cited by 685
(1987) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(87)90055-3 · Cited by 640
Cited by
Balancing forces: architectural control of mechanotransduction
DuFort, C. C., Paszek, M. J., & Weaver, V. M. (2011) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3112 · Cited by 985
Merger of structure and material in nacre and bone – Perspectives on de novo biomimetic materials
Espinosa, H. D., Rim, J. E., Barthelat, F., & Buehler, M. J. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2009.05.001 · Cited by 817
Self-citationProcessing of collagen based biomaterials and the resulting materials properties
Meyer, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0647-0 · Cited by 539
The pathogenesis of tendinopathy: balancing the response to loading
Magnusson, S. P., Langberg, H., & Kjaer, M. (2010) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2010.43 · Cited by 498
The materials science of collagen
Sherman, V. R., Yang, W., & Meyers, M. A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.05.023 · Cited by 324
Metadata
- Authors
- Buehler, M. J.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2008-01
- Volume
- 1
- Issue
- 1
- Pages
- 59-67
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2055076161
- Cited by
- 356
- References
- 42
- FWCI
- 7.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanomechanics of collagen fibrils under varying cross-link densities: Atomistic and continuum studies. https://app.cochat.ai/papers/10.1016/j.jmbbm.2007.04.001
- The paper
- Buehler, M. J. (2008). Nanomechanics of collagen fibrils under varying cross-link densities: Atomistic and continuum studies. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2007.04.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.