The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Mechanical aspects of dental implants and osseointegration: A narrative review
Abstract
With the need of rapid healing and long-term stability of dental implants, the existing Ti-based implant materials do not meet completely the current expectation of patients. Low elastic modulus Ti-alloys have shown superior biocompatibility and can achieve comparable or even faster bone formation in vivo at the interface of bone and the implant. Porous structured Ti alloys have shown to allow rapid bone ingrowth through their open structure and to achieve anchorage with bone tissue by increasing the bone-implant interface area. In addition to the mechanical properties of implant materials, the design of the implant body can be used to optimize load transfer and affect the ultimate results of osseointegration. The aim of this narrative review is to define the mechanical properties of dental implants, summarize the relationship between implant stability and osseointegration, discuss the effect of metallic implant mechanical properties (e.g. stiffness and porosity) on the bone response based on existing in vitro and in vivo information, and analyze load transfer through mechanical properties of the implant body. This narrative review concluded that although several studies have presented the advantages of low elastic modulus or high porosity alloys and their effect on osseointegration, further in vivo studies, especially long-term observational studies are needed to justify these novel materials as a replacement for current Ti-based implant materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Verborgt, O., Gibson, G. J., & Schaffler, M. B. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.1.60 · Cited by 731
Cited by
Recent Advances in 3D Printing of Smart Scaffolds for Bone Tissue Engineering and Regeneration
Yuan, X., Zhu, W., Yang, Z., He, N., Chen, F., Han, X., & Zhou, K. (2024) · Advanced Materials · doi:10.1002/adma.202403641 · Cited by 339
Metadata
- Authors
- Li, J., Jansen, J. A., Walboomers, X. F., & van den Beucken, J. J.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 103
- Pages
- 103574
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2992630144
- Cited by
- 232
- References
- 4
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical aspects of dental implants and osseointegration: A narrative review. https://app.cochat.ai/papers/10.1016/j.jmbbm.2019.103574
- The paper
- Li, J., Jansen, J. A., Walboomers, X. F., & van den Beucken, J. J. (2020). Mechanical aspects of dental implants and osseointegration: A narrative review. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2019.103574
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.