Effect of fused filament fabrication parameters on crashworthiness studies of hydroxyapatite particle reinforced PLA composite thin-walled tubes
Abstract
Hydroxyapatite-reinforced Poly Lactic Acid (PLA) thermoplastic composite is mainly used for scaffolding and bone implant applications. They are developed using the naturally derived hydroxyapatite particles from marine industry waste, which proves to be economical and has ecological benefits towards the composite development. The mechanical and dimensional stability of the 3D printed composite can be varied based on the mineralogical and structural characteristics of the added particle reinforcement into the matrix. The present work concentrates on developing thin-walled PLA/hydroxyapatite composite tubes using fused filament fabrication technology by the novel extruded PLA/hydroxyapatite composite filament. For the current study, the hydroxyapatite particles are derived from crab shell waste, and the tube was fabricated with a wall thickness of 4 mm. In this work, the prepared composite tube's crashworthiness behavior and dimensional stability are studied concerning various experimental parameters such as build orientation, line width, printing speed, nozzle temperature, and layer height. The experimental parameters were optimized using the Taguchi optimization technique. The results showed that the optimized parameters for the maximum compressive strength would be a build orientation of 90°, a lower layer height of 0.1 mm, a nominal printing speed of 20 mm/s, a moderate nozzle temperature of 220 °C, and a line width of 0.2 mm. The rank of influential experimental parameters…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
One advantage of combining PLA with bioceramics is the possibility of additive manufacturing, enabling a high degree of personalization.
“One advantage of combining PLA with bioceramics is the possibility of additive manufacturing, enabling a high degree of personalization [169,188,189,190,191,192].”
From Resorbable Biomaterials Used for 3D Scaffolds in Tissue Engineering: A Review (2023) · cites this paper as [188]
Cited by
Sorted by citations
Resorbable Biomaterials Used for 3D Scaffolds in Tissue Engineering: A Review
Vach Agocsova, S., Culenova, M., Birova, I., Omanikova, L., Moncmanova, B., Danisovic, L., Ziaran, S., Bakos, D., & Alexy, P. (2023) · Materials · doi:10.3390/ma16124267 · Cited by 98 · see citing works
- Authors
- Mathiazhagan, N., Palaniyappan, S., & Sivakumar, N. K.
- Affiliations
- Meenakshi Academy of Higher Education and Research (IN)
- Saveetha University (IN)
- Corresponding author
- Palaniyappan, Sabarinathan
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2023-02
- Volume
- 138
- Pages
- 105611
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W4312129491
- Cited by
- 48
- References
- 0
- Citations by year
- 2026: 9 · 2025: 13 · 2024: 8 · 2023: 18
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Automotive Engineering › Additive Manufacturing and 3D Printing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Physical Sciences › Engineering › Building and Construction › Innovations in Concrete and Construction Materials
- Keywords
- fused deposition modeling, hydroxyapatite, polylactic acid, thin-walled tubes, crashworthiness, compressive strength, dimensional stability, build orientation, layer thickness, printing speed, nozzle temperature, line width, crab shell waste, fracture mode, Taguchi method
- MeSH terms
- Cytoskeleton, Humans, Polyesters, Durapatite, Compressive Strength, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review