Cited by 50Magnetic Properties of AlloysMagnetic Properties and ApplicationsElectric Motor Design and Analysis

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

An adjustable linear Halbach array

Open access
Hilton, J.E., McMurry, S.M.·2012·Journal of Magnetism and Magnetic Materials

Overview

Integrity signals

Registry

Crossref · 10.1016/j.jmmm.2012.02.014

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 9

  1. Coey, 2002, Permanent magnet applications, Journal of Magnetism and Magnetic Materials, 248, 441, 10.1016/S0304-8853(02)00335-9 · DOI
  2. Mallinson, 1973, One-sided fluxes—a magnetic curiosity?, IEEE Transactions on Magnetics, 9, 678, 10.1109/TMAG.1973.1067714 · DOI
  3. J. Juanhuix, M. Traveria, Magnetic design and light characteristics of a Wiggler for the LLS, in: The Sixth European Particle Accelerator Conference, Stockholm, Sweden, June 1998, p. 2228.
  4. Ni Mhiochain, 1999, Analysis of torque in nested magnetic cylinders, Journal of Applied Physics, 86, 6412, 10.1063/1.371705 · DOI
  5. Hilton, 2007, Halbach cylinders with improved field homogeneity and tailored gradient fields, IEEE Transactions on Magnetics, 43, 1898, 10.1109/TMAG.2007.891727 · DOI
  6. Peng, 2003, Cylindrical permanent-magnet structures using images in an iron shield, IEEE Transactions on Magnetics, 39, 1983, 10.1109/TMAG.2003.814286 · DOI
  7. Cugat, 1994, Permanent magnet variable flux sources, IEEE Transactions on Magnetics, 30, 4602, 10.1109/20.334162 · DOI
  8. Bjørk, 2010, Comparison of adjustable permanent magnetic field sources, Journal of Magnetism and Magnetic Materials, 322, 3664, 10.1016/j.jmmm.2010.07.022 · DOI
  9. Bjørk, 2011, The ideal dimensions of a Halbach cylinder of finite length, Journal of Applied Physics, 109, 013915, 10.1063/1.3525646 · DOI

Cited by

Sorted by citations

Metadata

Authors
Hilton, J. E., & McMurry, S. M.
Affiliations
  • Commonwealth Scientific and Industrial Research Organisation (AU)
  • Trinity College Dublin (IE)
Corresponding author
Hilton, J.E.
Venue
Journal of Magnetism and Magnetic Materials
Publisher
Elsevier BV
Published
2012-07
Volume
324
Issue
13
Pages
2051-2056
ISSN
0304-8853 (ISSN-L)
OpenAlex
W2036439586
Cited by
50
References
1
Citations by year
2026: 3 · 2025: 8 · 2024: 7 · 2023: 3 · 2022: 5 · 2021: 6 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 5 · 2016: 2 · 2013: 1
FWCI
0.12
Type
journal article
Language
en
Open access
Locations
  • Journal of Magnetism and Magnetic Materials (publishedVersion)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion, cc-by-nc-sa)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties of Alloys
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
Keywords
Halbach array, rotating magnet

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review