The DOI matches its Crossref record.
Intertester Reliability and Diagnostic Validity of the Cervical Flexion-Rotation Test
Abstract
OBJECTIVE: This article evaluates reliability and diagnostic validity of the cervical flexion-rotation test (FRT) to discriminate subjects with headache because of C1/2 dysfunction. In addition, this study evaluates agreement between experienced and inexperienced examiners. METHODS: These were 2 single blind comparative measurement study designs. In study 1, 2 experienced blinded examiners evaluated the FRT in 10 asymptomatic controls, 20 subjects with cervicogenic headache (CeH) where C1/2 was the primary dysfunctional level, and 10 subjects with CeH but without C1/2 as the primary dysfunctional level. In study 2, 2 inexperienced and 1 experienced blinded examiners evaluated the FRT in 12 subjects with CeH and 12 asymptomatic controls. Examiners were required to state whether the FRT was positive and also to determine range of rotation using a goniometer. An analysis of variance with planned orthogonal comparison, single measure intraclass correlation coefficient (2,1), and Bland-Altman plot were used to analyze FRT range of rotation between the examiners. Sensitivity, specificity, and examiner agreement for test interpretation were analyzed using cross tabulation and kappa. RESULTS: In study 1, sensitivity and specificity of the FRT was 90% and 88% with 92% agreement for experienced examiners (P < .001). Overall diagnostic accuracy was 89% (P < .001) and kappa = 0.85. In study 2, for inexperienced examiners, FRT mobility was significantly greater than for experienced examiners, but sensitivity, specificity, agreement, and kappa values were all within clinically acceptable levels. CONCLUSIONS: The FRT can be used accurately and reliably by inexperienced examiners and may be a useful aid in CeH evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed
Kottner, J., Audigé, L., Brorson, S., Donner, A., Gajewski, B. J., Hróbjartsson, A., Roberts, C., Shoukri, M., & Streiner, D. L. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.03.002 · Cited by 2,174
Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed
Kottner, J., Audige, L., Brorson, S., Donner, A., Gajewski, B. J., Hróbjartsson, A., Roberts, C., Shoukri, M., & Streiner, D. L. (2011) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2011.01.016 · Cited by 997
Blanpied, P. R., Gross, A. R., Elliott, J. M., Devaney, L. L., Clewley, D., Walton, D. M., Sparks, C., & Robertson, E. K. (2017) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2017.0302 · Cited by 979
Metadata
- Authors
- Hall, T. M., Robinson, K. W., Fujinawa, O., Akasaka, K., & Pyne, E. A.
- Venue
- Journal of Manipulative and Physiological Therapeutics
- Publisher
- Elsevier BV
- Published
- 2008-05
- Volume
- 31
- Issue
- 4
- Pages
- 293-300
- ISSN
- 0161-4754 (ISSN-L)
- OpenAlex
- W2000331761
- Cited by
- 164
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intertester Reliability and Diagnostic Validity of the Cervical Flexion-Rotation Test. https://app.cochat.ai/papers/10.1016/j.jmpt.2008.03.012
- The paper
- Hall, T. M., Robinson, K. W., Fujinawa, O., Akasaka, K., & Pyne, E. A. (2008). Intertester Reliability and Diagnostic Validity of the Cervical Flexion-Rotation Test. Journal of Manipulative and Physiological Therapeutics. https://doi.org/10.1016/j.jmpt.2008.03.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.