A large volume flat coil probe for oriented membrane proteins
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Input power of 65 W was needed to obtain a 1 H f 1 value of 50 kHz in a paraffinic oil reference”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [16]
In the citing paper
“Obtaining the same level of 1 Hdecoupling field for this lossy sample required 260 W of input power, meaning that 195 W or 75% of the input 1 H power heats the biological system.”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [16]
In the citing paper
“As a rule, we balance the 1 H circuit before each s 90 measurement to maintain equal voltages at the ends of the coil [16].”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [16]
In the citing paper
“When loaded into the coil, this sample reduced the 1 H channel efficiency by a factor of 2.”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [16]
In the citing paper
“A previously reported 8 · 6 · 12 mm flat-coil solenoid [16] sees its 1 H RF field drop by a factor of 2 at 600 MHz with certain hydrated bilayer preparations”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [16]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Resolution Heteronuclear Dipolar Solid-State NMR Spectroscopy
Wu, C. H., Ramamoorthy, A., & Opella, S. J. (1994) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1994.1169 · Cited by 434
Structure Determination of Membrane Proteins by NMR Spectroscopy
Opella, S. J., & Marassi, F. M. (2004) · Chemical Reviews · doi:10.1021/cr0304121 · Cited by 425
Ketchem, R., Roux, B., & Cross, T. (1997) · Structure · doi:10.1016/s0969-2126(97)00312-2 · Cited by 259
Self-citationStructure of the transmembrane region of the M2 protein H+ channel
Wang, J., Kim, S., Kovacs, F., & Cross, T. A. (2001) · Protein Science · doi:10.1110/ps.17901 · Cited by 233
Self-citationRadiofrequency losses in NMR experiments on electrically conducting samples
Gadian, D. G., & Robinson, F. N. H. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90023-4 · Cited by 172
Research works printed but not linked: 27
- Nevzorov, 2004, Structure determination of aligned samples of membrane proteins by NMR spectroscopy, Magn. Reson. Chem., 42, 162, 10.1002/mrc.1320 · DOI
- Walian, 2004, Structural genomics of membrane proteins, Genome Biol., 5, 10.1186/gb-2004-5-4-215 · DOI
- Denny, 2001, PISEMA powder patterns and PISA wheels, J. Magn. Reson., 152, 217, 10.1006/jmre.2001.2405 · DOI · Paper page
- Opella, 2002, Structure determination of membrane proteins by NMR spectroscopy, Biochem. Cell Biol., 80, 597, 10.1139/o02-154 · DOI
- Cross, 1976, Single coil probe with transmission-line tuning for nuclear magnetic double-resonance, Rev. Sci. Instrum., 47, 1486, 10.1063/1.1134560 · DOI
- Kan, 1980, A single-coil triple resonance probe for NMR experiments, Rev. Sci. Instrum., 51, 887, 10.1063/1.1136352 · doi:10.1063/1.1136352
- Doty, 1981, A multinuclear double-tuned probe for applications with solids or liquids utilizing lumped tuning elements, J. Magn. Reson., 43, 399
- Jiang, 1987, An efficient double-tuned 13C/1H probe circuit for CP/MAS NMR and its importance in linewidths, J. Magn. Reson., 71, 485
- Paulson, 2004, Cross polarization, radio frequency field homogeneity, and circuit balancing in high field solid-state NMR probes, J. Magn. Reson., 171, 314, 10.1016/j.jmr.2004.09.009 · DOI · Paper page
- Salom, 2000, pH-dependent tetramerization and amantadine binding of the transmembrane helix of M2 from the influenza A virus, Biochemistry, 39, 14160, 10.1021/bi001799u · DOI
- Nishimura, 2002, The closed state of a H+ channel helical bundle combining precise orientational and distance restraints from solid state NMR, Biochemistry, 41, 13170, 10.1021/bi0262799 · DOI · Paper page
- Kovacs, 2000, Helix tilt of the M2 transmembrane peptide from influenza A virus: An intrinsic property, J. Mol. Biol., 295, 117, 10.1006/jmbi.1999.3322 · DOI
- Silphaduang, 2001, Antimicrobials—Peptide antibiotics in mast cells of fish, Nature, 414, 268, 10.1038/35104690 · DOI · Paper page
- Engelke, 2002, Electromagnetic wave compression and radio frequency homogeneity in NMR solenoidal coils: computational approach, Concepts Magn. Reson., 15, 129, 10.1002/cmr.10029 · DOI
- Martin, 2003, Design of a triple resonance magic angle sample spinning probe for high field solid state nuclear magnetic resonance, Rev. Sci. Instrum., 74, 3045, 10.1063/1.1571951 · DOI · Paper page
- Stuhlman, 1932, The magnetic field of a solenoid oscillating at radio frequencies, Rev. Sci. Instrum., 3, 561, 10.1063/1.1748871 · DOI · Paper page
- Zhang, 1998, J. Magn. Reson., 132, 167, 10.1006/jmre.1998.1386 · DOI
- Lipton, 2001, A general strategy for the NMR observation of half-integer quadrupolar nuclei in dilute environments, J. Magn. Reson., 151, 48, 10.1006/jmre.2001.2353 · DOI
- Li, 2006, Analysis of RF heating and sample stability in aligned static solid state NMR spectroscopy, J. Magn. Reson., 179, 361
- Gu, 1999, Three-dimensional 13C shift/1H-15N Coupling/15N shift solid-state NMR correlation spectroscopy, J. Magn. Reson., 138, 193, 10.1006/jmre.1999.1709 · DOI
- Tian, 2003, Initial structural and dynamic characterization of the M2 protein transmembrane and amphipatic helices in lipid bilayers, Protein Sci., 12, 2597, 10.1110/ps.03168503 · DOI
- Chekmenev, 2005, 15N and 31P solid-state NMR study of transmembrane domain alignment of M2 protein of influenza A virus in hydrated cylindrical lipid bilayers confined to anodic aluminum oxide nanopores, J. Magn. Reson., 173, 322, 10.1016/j.jmr.2004.12.006 · DOI
- Idziak, 1982, Design and construction of a high homogeneity RF coil for solid-state multiple-pulse NMR, J. Magn. Reson., 50, 281
- Leifer, 1993, RF solenoid with extended equiripple field profile, J. Magn. Reson., 105, 1, 10.1006/jmra.1993.1240 · doi:10.1006/jmra.1993.1240
- Privalov, 1996, Coil design for large volume high-B1 homogeneity for solid-state NMR applications, J. Magn. Reson., 123, 157, 10.1006/jmra.1996.0229 · doi:10.1006/jmra.1996.0229
- Hoult, 1978, The NMR receiver: a description and analysis of design, Progr. In NMR Spect., 12, 41, 10.1016/0079-6565(78)80002-8 · DOI
- Alderman, 1979, An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometers, J. Magn. Reson., 36, 447
Cited by
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
Self-citationVostrikov, V. V., Mote, K. R., Verardi, R., & Veglia, G. (2013) · Structure · doi:10.1016/j.str.2013.09.008 · Cited by 48
Metadata
- Authors
- Gor’kov, P. L., Chekmenev, E. Y., Fu, R., Hu, J., Cross, T. A., Cotten, M., & Brey, W. W.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2006-07
- Volume
- 181
- Issue
- 1
- Pages
- 9-20
- ISSN
- 1090-7807
- Cited by
- 30
- References
- 5
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.