Improving excitation and inversion accuracy by optimized RF pulse using genetic algorithm
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For their optimization, we proposed the use of a Genetic Algorithm (GA) that has been successful for designing new experiments [2] improving excitation and inversion of RF pulses [3], as well as optimizing existing pulse sequences [4].”
From Optimization of identity operation in NMR spectroscopy via genetic algorithm: Application to the TEDOR experiment (2016) · cites this paper as [3]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 17
- Pauly, 1989, A k-space analysis of small-tip-angle excitation, J. Magn. Reson., 81, 43
- Pauly, 1989, A linear class of large-tip-angle selective excitation pulses, J. Magn. Reson., 82, 571
- Hardy, 1989, Broadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity, J. Appl. Phys., 66, 1513, 10.1063/1.344411 · doi:10.1063/1.344411
- Hardy, 1989, Spatial location in two dimensions using NMR designer pulses, J. Magn. Reson., 82, 647
- Bottomley, 1987, Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse, J. Appl. Phys., 62, 4284, 10.1063/1.339103 · doi:10.1063/1.339103
- Pauly, 1993, Echo-planar spin echo and inversion pulses, Magn. Res. Med., 29, 776, 10.1002/mrm.1910290609 · doi:10.1002/mrm.1910290609
- Pauly, 1993, A three-dimensional spin-echo or inversion pulse, Magn. Res. Med., 28, 2, 10.1002/mrm.1910290103 · DOI
- Pauly, 1991, Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm, IEEE Trans. Med. Imaging, 10, 53, 10.1109/42.75611 · DOI · Paper page
- Buonocore, 1991, A Shinnar-Le Roux type algorithm for design of 2-D and 3-D spatially selective RF pulses, Society for Magnetic Resonance Imaging, 145
- Pauly, 1993, Echo-planar spin-echo and inversion pulses, Magn. Res. Med., 29, 776, 10.1002/mrm.1910290609 · doi:10.1002/mrm.1910290609
- Freeman, 1987, Design of magnetic resonance experiments by genetic evolution, J. Magn. Reson, 75, 184
- Wu, 1989, Darwin’s ideas applied to magnetic resonance, the marriage broker, J. Magn. Reson, 85, 414
- Wu, 1991, Delayed-Focus pulses for magnetic resonance imaging: an evolutionary approach, Magn. Res. Med., 20, 165, 10.1002/mrm.1910200118 · DOI
- Suckley, 1991, Genetic algorithm in the design of FIR filters, IEE Proc. on circuits, devices and systems, 138, 234, 10.1049/ip-g-2.1991.0043 · doi:10.1049/ip-g-2.1991.0043
- Lee, 1999, Design of 1-D FIR filters with genetic algorithms, Proc. IEEE Int. Symp. Circuits and Systems, 295
- Oner, 1998, A genetic algorithm for optimisation of linear phase FIR filter coefficients, Conference record of the thirty-second asilomar conference on Signals, Systems & Computers, 1397, 10.1109/ACSSC.1998.751556 · doi:10.1109/acssc.1998.751556
- Ahmed, 2003, Design of FIR filters with arbitrary amplitude and phase specifications using genetic algorithm, IEEE Proc. circuits and systems, 2, 27
Cited by
Genetic algorithm optimized triply compensated pulses in NMR spectroscopy
Manu, V. S., & Veglia, G. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.09.010 · Cited by 26
“This approach has been previously applied for designing new NMR experiments [20], improving RF excitation and inversion accuracy [21], and optimizing simple pulse sequences [22-24].”
MethodManu, V. S., & Veglia, G. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.09.021 · Cited by 14
Subrahmanian, M. V., Dregni, A. J., & Veglia, G. (2017) · Modern Magnetic Resonance · doi:10.1007/978-3-319-28275-6_71-1 · Cited by 2
Metadata
- Authors
- Pang, Y., & Shen, G. X.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2007-05
- Volume
- 186
- Issue
- 1
- Pages
- 86-93
- ISSN
- 1090-7807
- Cited by
- 17
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.