Abstract
The use of genetic algorithms for the optimisation of magic angle spinning NMR pulse sequences is discussed. The discussion uses as an example the optimisation of the C7(2)(1) dipolar recoupling pulse sequence, aiming to achieve improved efficiency for spin systems characterised by large chemical shielding anisotropies and/or small dipolar coupling interactions. The optimised pulse sequence is found to be robust over a wide range of parameters, requires only minimal a priori knowledge of the spin system for experimental implementations with buildup rates being solely determined by the magnitude of the dipolar coupling interaction, but is found to be less broadbanded than the original C7(2)(1) pulse sequence. The optimised pulse sequence breaks the synchronicity between r.f. pulses and sample spinning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In fact, recent work by Manu and Kumar shows that GA can be successfully applied to pulse sequence optimization [22-24].”
From Genetic algorithm optimized triply compensated pulses in NMR spectroscopy (2015) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Khaneja, N., Reiss, T., Kehlet, C., Schulte-Herbrüggen, T., & Glaser, S. J. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2004.11.004 · Cited by 1,854 · cited 1×
“The numerical approaches (specifically the GRAPE or Krotov implementations of optimal control [34, 45]) and GA algorithms have in common that both can be applied to some extent in a black-box fashion.”
MethodFortunato, E. M., Pravia, M. A., Boulant, N., Teklemariam, G., Havel, T. F., & Cory, D. G. (2002) · The Journal of Chemical Physics · doi:10.1063/1.1465412 · Cited by 243
Decoherence can be useful in quantum walks
Kendon, V., & Tregenna, B. (2003) · Physical Review A · doi:10.1103/physreva.67.042315 · Cited by 223 · cited 1×
“We note in passing that the occurrence of small deviations from perfect symmetry having major impacts is quite common in the physical world, ranging, for example, from so-called incommensurate structures in crystallography [64] to the properties of viruses [32], or the effects of minor decoherences in quantum informat…”
Background
Research works printed but not linked: 52
- Laws, 2002, Solid-state NMR spectroscopic methods in chemistry, Angewandte Chemie International Edition, 41, 3096, 10.1002/1521-3773(20020902)41:17<3096::AID-ANIE3096>3.0.CO;2-X · DOI · Paper page
- Jaroniec, 2000, Recoupling of heteronuclear dipolar interactions with rotational-echo double-resonance at high magic-angle spinning frequencies, Journal of Magnetic Resonance, 146, 132, 10.1006/jmre.2000.2128 · DOI
- Brinkmann, 2001, Symmetry principles in the nuclear magnetic resonance of spinning solids: Heteronuclear recoupling by generalized Hartmann–Hahn sequences, Journal of Chemical Physics, 115, 357, 10.1063/1.1377031 · DOI
- Chen, 2010, Measurement of hetero-nuclear distances using a symmetry-based pulse sequence in solid-state NMR, Physical Chemistry Chemical Physics, 12, 9395, 10.1039/b926546e · doi:10.1039/b926546e
- Carravetta, 2001, Estimation of carbon–carbon bond lengths and medium-range internuclear distances by solid-state nuclear magnetic resonance, Journal of the American Chemical Society, 123, 10628, 10.1021/ja016027f · DOI
- Brinkmann, 2002, Homonuclear zero-quantum recoupling in fast magic-angle spinning nuclear magnetic resonance, Journal of Magnetic Resonance, 156, 79, 10.1006/jmre.2002.2525 · DOI
- auf der Günne, 2003, Distance measurements in spin-1/2 systems by 13C and 31P solid-state NMR in dense dipolar networks, Journal of Magnetic Resonance, 165, 18, 10.1016/S1090-7807(03)00242-8 · DOI
- Brouwer, 2005, Symmetry-based 29Si dipolar recoupling magic angle spinning NMR spectroscopy: a new method for investigating three-dimensional structures of zeolite frameworks, Journal of the American Chemical Society, 127, 542, 10.1021/ja043228l · doi:10.1021/ja043228l
- Leskes, 2010, Floquet theory in solid-state nuclear magnetic resonance, Progress in Nuclear Magnetic Resonance Spectroscopy, 57, 345, 10.1016/j.pnmrs.2010.06.002 · DOI · Paper page
- Hohwy, 1997, Elimination of high order terms in multiple pulse nuclear magnetic resonance spectroscopy: application to homonuclear decoupling in solids, The Journal of Chemical Physics, 106, 7571, 10.1063/1.473760 · DOI
- Brinkmann, 2004, Second order average hamiltonian theory of symmetry-based pulse schemes in the nuclear magnetic resonance of rotating solids: application to triple-quantum dipolar recoupling, The Journal of Chemical Physics, 120, 11726, 10.1063/1.1738102 · doi:10.1063/1.1738102
- Levitt, 2002, Symmetry-based pulse sequences in magic-angle spinning solid-state NMR, vol. 9, 165
- Kristiansen, 2004, A robust pulse sequence for the determination of small homonuclear dipolar couplings in magic-angle spinning NMR, Chemical Physics Letters, 390, 1, 10.1016/j.cplett.2004.03.075 · DOI
- Kristiansen, 2006, Theory and applications of supercycled symmetry-based recoupling sequences in solid-state nuclear magnetic resonance, The Journal of Chemical Physics, 124, 234510, 10.1063/1.2205857 · DOI
- Levitt, 1996, Composite pulses, vol. 2, 1396
- Boulant, 2008, Strongly modulating pulses for counteracting RF inhomogeneity at high fields, Magnetic Resonance in Medicine, 60, 701, 10.1002/mrm.21700 · DOI
- Mitra, 2008, NMR implementation of adiabatic SAT algorithm using strongly modulated pulses, The Journal of Chemical Physics, 128, 124110, 10.1063/1.2835542 · DOI
- Glaser, 1998, Unitary control in quantum ensembles: maximizing signal intensity in coherent spectroscopy, Science, 280, 421, 10.1126/science.280.5362.421 · DOI · Paper page
- Tosner, 2009, Optimal control in NMR spectroscopy: numerical implementation in SIMPSON, Journal of Magnetic Resonance, 197, 120, 10.1016/j.jmr.2008.11.020 · DOI · Paper page
- Nielsen, 2009, Symmetry-based dipolar recoupling by optimal control: Band-selective experiments for assignment of solid-state NMR spectra of proteins, The Journal of Chemical Physics, 131, 025101, 10.1063/1.3157737 · DOI
- Sakellariou, 2000, Homonuclear dipolar decoupling in solid-state NMR using continuous phase modulation, Chemical Physics Letters, 319, 253, 10.1016/S0009-2614(00)00127-5 · DOI · Paper page
- Paëpe, 2003, Improved heteronuclear decoupling schemes for solid-state magic angle spinning NMR by direct spectral optimization, Chemical Physics Letters, 376, 259, 10.1016/S0009-2614(03)00966-7 · DOI
- R. Freeman, X. Wu, Design of magnetic resonance experiments by genetic evolution, Journal of Magnetic Resonance (1969) 75(1) (1987) 184–189. · DOI
- Pang, 2007, Improving excitation and inversion accuracy by optimized RF pulse using genetic algorithm, Journal of Magnetic Resonance, 186, 86, 10.1016/j.jmr.2007.01.016 · DOI
- Herbst, 2009, Numerical design of RNnν symmetry-based RF pulse schemes for recoupling and decoupling of nuclear spin interactions at high MAS frequencies, Journal of Biomolecular NMR, 44, 235, 10.1007/s10858-009-9335-x · DOI
- Grimminck, 2011, EASY-GOING DUMBO on-spectrometer optimisation of phase modulated homonuclear decoupling sequences in solid-state NMR, Chemical Physics Letters, 509, 186, 10.1016/j.cplett.2011.04.079 · DOI
- Bjerring, 2003, Solid-state NMR heteronuclear dipolar recoupling using off-resonance symmetry-based pulse sequences, Chemical Physics Letters, 370, 496, 10.1016/S0009-2614(03)00103-9 · DOI
- Marin-Montesinos, 2005, Heteronuclear decoupling interference during symmetry-based homonuclear recoupling in solid-state NMR, Journal of Magnetic Resonance, 177, 307, 10.1016/j.jmr.2005.07.020 · DOI
- Leskes, 2011, Radio frequency assisted homonuclear recoupling – a floquet description of homonuclear recoupling via surrounding heteronuclei in fully protonated to fully deuterated systems, Journal of Magnetic Resonance, 209, 207, 10.1016/j.jmr.2011.01.015 · DOI
- Hibbert, 1993, Genetic algorithms in chemistry, Chemometrics and Intelligent Laboratory Systems, 19, 277, 10.1016/0169-7439(93)80028-G · DOI · Paper page
- Carravetta, 2000, Symmetry principles for the design of radiofrequency pulse sequences in the nuclear magnetic resonance of rotating solids, Chemical Physics Letters, 321, 205, 10.1016/S0009-2614(00)00340-7 · doi:10.1016/s0009-2614(00)00340-7
- Karlsson, 2003, A study of homonuclear dipolar recoupling pulse sequences in solid-state nuclear magnetic resonance, Journal of the American Chemical Society, 125, 7394, 10.1021/ja0294360 · DOI
- Brinkmann, 2000, Synchronous helical pulse sequences in magic-angle spinning nuclear magnetic resonance: double quantum recoupling of multiple-spin systems, The Journal of Chemical Physics, 112, 8539, 10.1063/1.481458 · DOI
- Bak, 2000, SIMPSON: a general simulation program for solid-state NMR spectroscopy, Journal of Magnetic Resonance, 147, 296, 10.1006/jmre.2000.2179 · DOI · Paper page
- Dusold, 1999, Magnitudes and orientations of interaction tensors determined from rotational resonance MAS NMR lineshapes of a four-13C-spin system, Journal of Magnetic Resonance, 141, 78, 10.1006/jmre.1999.1865 · doi:10.1006/jmre.1999.1865
- Baldus, 1998, Broadband dipolar recoupling in rotating solids: a numerical comparison of some pulse schemes, Solid State Nuclear Magnetic Resonance, 11, 157, 10.1016/S0926-2040(98)00036-8 · DOI
- James, 1975, MINUIT – a system for function minimization and analysis of the parameter errors and correlations, Computer Physics Communications, 10, 343, 10.1016/0010-4655(75)90039-9 · DOI · Paper page
- Press, 1992
- Scholz, 2010, Operator-based floquet theory in solid-state NMR, Solid State Nuclear Magnetic Resonance, 37, 39, 10.1016/j.ssnmr.2010.04.003 · DOI
- Wächtler, 2009, Efficient analysis of 51v solid-state MAS NMR spectra using genetic algorithms, Solid State Nuclear Magnetic Resonance, 35, 37, 10.1016/j.ssnmr.2008.11.003 · doi:10.1016/j.ssnmr.2008.11.003
- Ong, 2006, Classification of adaptive memetic algorithms: a comparative study, Systems, Man, and Cybernetics, IEEE Transactions on Part B: Cybernetics, 36, 141
- Maximov, 2008, Optimal control design of NMR and dynamic nuclear polarization experiments using monotonically convergent algorithms, The Journal of Chemical Physics, 128, 184505, 10.1063/1.2903458 · DOI
- Maximov, 2010, A smoothing monotonic convergent optimal control algorithm for nuclear magnetic resonance pulse sequence design, The Journal of Chemical Physics, 132, 084107, 10.1063/1.3328783 · DOI
- Roy, 2009, Genetic algorithm based optimal control of smart composite shell structures under mechanical loading and thermal gradient, Smart Materials and Structures, 18, 115006, 10.1088/0964-1726/18/11/115006 · doi:10.1088/0964-1726/18/11/115006
- Park, 2004, Optimal control by evolutionary algorithm technique combined with spline approximation method, Chemical Engineering Communications, 191, 262, 10.1080/0098644049026188 · doi:10.1080/0098644049026188
- Zeidler, 2001, Evolutionary algorithms and their application to optimal control studies, Physical Review A, 64, 023420, 10.1103/PhysRevA.64.023420 · DOI · Paper page
- Amstrup, 1995, Genetic algorithm with migration on topology conserving maps for optimal control of quantum systems, The Journal of Physical Chemistry, 99, 5206, 10.1021/j100014a048 · DOI
- Michalewicz, 1992, A modified genetic algorithm for optimal control problems, Computers & Mathematics with Applications, 23, 83, 10.1016/0898-1221(92)90094-X · DOI
- Hughes, 2004, Radio-frequency driven polarization transfer without heteronuclear decoupling in rotating solids, Chemical Physics Letters, 385, 435, 10.1016/j.cplett.2004.01.009 · DOI
- Van Smallen, 1995, Incommensurate crystal structures, Crystallography Reviews, 4, 79, 10.1080/08893119508039920 · doi:10.1080/08893119508039920
- Keef, 2008, New insights into viral architecture via affine extended symmetry groups, Computational and Mathematical Methods in Medicine, 9, 221, 10.1080/17486700802168163 · DOI
- Miller, 2000, Cartesian genetic programming, vol. 1802, 121
Cited by
Genetic algorithm optimized triply compensated pulses in NMR spectroscopy
Manu, V. S., & Veglia, G. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.09.010 · Cited by 26
Manu, V. S., & Veglia, G. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.09.021 · Cited by 14
Subrahmanian, M. V., Dregni, A. J., & Veglia, G. (2017) · Modern Magnetic Resonance · doi:10.1007/978-3-319-28275-6_71-1 · Cited by 2
Metadata
- Authors
- Bechmann, M., Clark, J., & Sebald, A.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2013-03
- Volume
- 228
- Pages
- 66-75
- ISSN
- 1090-7807
- Cited by
- 18
- References
- 3
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Genetic algorithms and solid state NMR pulse sequences. https://app.cochat.ai/papers/10.1016/j.jmr.2012.12.015
- The paper
- Bechmann, M., Clark, J., & Sebald, A. (2013). Genetic algorithms and solid state NMR pulse sequences. Journal of Magnetic Resonance. https://doi.org/10.1016/j.jmr.2012.12.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.