Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index; none of the 19 sources its claims cite is checked for support yet.

Genetic algorithm optimized triply compensated pulses in NMR spectroscopy

Open access
Manu, V.S., Veglia, Gianluigi · 2015 · Journal of Magnetic Resonance

Abstract

Sensitivity and resolution in NMR experiments are affected by magnetic field inhomogeneities (of both external and RF), errors in pulse calibration, and offset effects due to finite length of RF pulses. To remedy these problems, built-in compensation mechanisms for these experimental imperfections are often necessary. Here, we propose a new family of phase-modulated constant-amplitude broadband pulses with high compensation for RF inhomogeneity and heteronuclear coupling evolution. These pulses were optimized using a genetic algorithm (GA), which consists in a global optimization method inspired by Nature’s evolutionary processes. The newly designed π and π/2 pulses belong to the ‘Type A’ (or general rotors) symmetric composite pulses. These GA-optimized pulses are relatively short compared to other general rotors and can be used for excitation and inversion, as well as refocusing pulses in spin-echo experiments. The performance of the GA-optimized pulses was assessed in Magic Angle Spinning (MAS) solid-state NMR experiments using a crystalline U – 13C, 15N NAVL peptide as well as U – 13C, 15N microcrystalline ubiquitin. GA optimization of NMR pulse sequences opens a window for improving current experiments and designing new robust pulse sequences.

Overview

CoChat Summary

TL;DR

The paper designs phase-modulated constant-amplitude broadband π and π/2 pulses using a genetic algorithm to compensate simultaneously for RF inhomogeneity, resonance offset, and zz interactions. The GA-optimized “type A” general rotors show >99% simulated fidelity over typical ranges and outperform comparator composite pulses by a new 99fidelity-rectangle figure of merit, with proof-of-concept MAS NMR tests in NAVL and microcrystalline ubiquitin.

Key findings

  • GA-optimized π/2 and π pulses with total nutation angle Θ = 5π achieved >99% fidelity over standard chemical-shift and RF-inhomogeneity ranges, with robust response for coupling strengths comparable to the applied RF field; the authors note these pulses are relatively short compared to other general rotors.
  • Using Θ = 9π produced nine-pulse phase modulations, e.g. {114.4°, 162.2°, 200.5°, 174.3°, 48.1°, 174.3°, 200.5°, 162.2°, 114.4°} weighted for RF compensation and {104.5°, 152°, 206.1°, 182.8°, 47.8°, 182.8°, 206.1°, 152°, 104.5°} weighted for offset.
  • In comparisons using the 99fidelity rectangle, GA pulses G1–G5 had better simultaneous compensation than ASBO-9(B1), ASBO-11(B1), and Jones et al. pulses; GA π/2 pulses were more robust than CORPSE and SCROFULOUS, and GA pulses had better compensation per unit Θ (A/Θ).
  • Experimental MAS NMR with NAVL (10 kHz spinning) and microcrystalline ubiquitin (12 kHz) showed GA π and π/2 pulses had improved offset response over hard pulses; for ubiquitin, the GA π pulse performed near uniformly at 60 W and 90 W, while a hard pulse generated offset effects of approximately ±10 kHz for CO and Cα chemical shifts.

Methods

  • Pulse design: GA in the MATLAB global optimization toolbox optimized 200 phase points for constant-amplitude shaped pulses; population size 50, 10^4 generations, elite count 2, Roulette selection, Uniform mutation rate 0.05, Arithmetic crossover, taking approximately 2 days on an Intel Core i7 (2.7 GHz) processor. Fitness was the volume under the fidelity surface over ΔB/B1⁰ from −1 to +1 and B1/B1⁰ from 0.5 to 1.5, with zz coupling constrained so only solutions with fidelity loss changes less than ~1% evolved. Robustness was also improved with Θ = 9π, 9.2π, and 11π.
  • Simulations: fidelity was calculated as F = Trace(Uθ^e × Uπ/2 or π†) for π/2 and π rotations; dual compensation was characterized by the “99fidelity rectangle,” the maximum rectangle centered at ΔB/B1⁰ = 0 and B1/B1⁰ = 1 with all fidelity points ≥99%.
  • Experiments: MAS solid-state NMR used crystalline N-acetyl-L-15N-valyl-L-15N-leucine (NAVL) on a VNMRS 700 MHz spectrometer at 10 kHz spinning, 298 K, and U-13C,15N microcrystalline ubiquitin on a Bruker AVANCEIII 700 MHz spectrometer at 12 kHz spinning, 298 K; each 1D spectrum used 128 scans and a 2 s relaxation delay. Representative offset-response experiments used RF amplitude 40 kHz and 62.5 μs duration; ubiquitin tests used 60 W and 90 W, where 60 W was the calibrated power for a 12.5 μs π pulse.

Limitations

  • The paper states that improving compensation by extending total nutation angle Θ has limitations due to long-range couplings and relaxation phenomena when pulsing time increases.
  • The paper states that experimental validation was proof-of-concept: generating an entire two-dimensional experimental profile would require a prohibitive number of experiments, so only representative offset-response experiments were performed.
  • Evident from the text: GA optimization is computationally expensive (~2 days for 200 phase points), and experimental tests are limited to two MAS solid-state samples; robustness to phase errors, CSA/spinning interference, and homonuclear dipolar coupling is reported mainly in supplementary simulations.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/j.jmr.2015.09.010

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 6 Not valid · 9 Not checked · 38 Own results and interpretations

19 more claims

Create a free account to see all 53 claims and to verify the 19 references still open.

See all claims — free account
  • It may state two separate claims as one. 14
  • Probably not a substantial claim. 15

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 47 references

Cited by

Metadata

Authors
Manu, V. S., & Veglia, G.
Affiliations
University of Minnesota (US)
Corresponding author
Veglia, Gianluigi
Venue
Journal of Magnetic Resonance
Publisher
Elsevier BV
Published
2015-11
Volume
260
Pages
136-143
ISSN
1090-7807 (ISSN-L)
OpenAlex
W1796970835
Cited by
26
References
47
Citations by year
2026: 3 · 2025: 2 · 2024: 4 · 2023: 1 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 1 · 2018: 2 · 2017: 2 · 2016: 1
FWCI
0.60
Type
journal article
Language
en
Open access
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Magnetic Resonance (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Health (GM 64742, GM 72701)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
Keywords
NMR pulse sequence design, genetic algorithm optimization, magic angle spinning, solid-state NMR, ubiquitin
MeSH terms
Algorithms, Electromagnetic Fields, Biological Evolution, Genetics, Microtubule-Associated Proteins, Magnetic Resonance Spectroscopy, Peptides, Ubiquitin

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.