The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
What is a Nearly zero energy building? Overview, implementation and comparison of definitions
Open accessAbstract
Abstract The reduction of energy consumption in buildings is an important pillar of the European strategy to ensure that future climate and energy targets are reached. This paper focuses on the definition of Nearly zero energy buildings (NZEBs) that represent one of the greatest opportunities to increase energy savings in Europe. As this term appears to be subject to different interpretations, the paper explores the NZEB literature to provide an overview of definitions. The analysis underlines inconsistencies and critical issues among them. The paper also assesses the progress of the NZEB implementation in Europe, and compares the EU-NZEBs and the US-NZEBs definitions. The main debates arisen around NZEBs are evaluated. Among these topics, there are: the distinction between energy and primary energy, and between energy sources and energy carriers. A focus is also due to metrics and primary energy conversion factors. Special attention is provided in defining primary energy factors for energy carriers produced from renewable energy sources on site, nearby or far. After specifying the role of “plus” buildings, a complementary energy index, useful for defining incentives for buildings is formulated to overcome the questioning on the “negative” primary energy index that can be achieved using some of current net ZEB definitions. A proposal for clarifying the meaning of near zero, zero and plus energy buildings is also given. The analysis highlights that, although the attention given to NZEBs increased over the last years, the NZEB topic is still under discussion and not uniformly implemented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zero Energy Building – A review of definitions and calculation methodologies
Marszal, A. J., Heiselberg, P., Bourrelle, J. S., Musall, E., Voss, K., Sartori, I., & Napolitano, A. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2010.12.022 · Cited by 1,162
Net zero energy buildings: A consistent definition framework
Sartori, I., Napolitano, A., & Voss, K. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.01.032 · Cited by 952
Overview and future challenges of nearly zero energy buildings (nZEB) design in Southern Europe
Attia, S., Eleftheriou, P., Xeni, F., Morlot, R., Ménézo, C., Kostopoulos, V., Betsi, M., Kalaitzoglou, I., Pagliano, L., Cellura, M., et al. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.043 · Cited by 327
European smart cities: The role of zero energy buildings
Kylili, A., & Fokaides, P. A. (2015) · Sustainable Cities and Society · doi:10.1016/j.scs.2014.12.003 · Cited by 309
Lu, Y., Wang, S., & Shan, K. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.06.007 · Cited by 232
A review of Net Zero Energy Buildings with reflections on the Australian context
Wells, L., Rismanchi, B., & Aye, L. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.055 · Cited by 210
Towards nearly zero-energy buildings: The state-of-art of national regulations in Europe
Annunziata, E., Frey, M., & Rizzi, F. (2013) · Energy · doi:10.1016/j.energy.2012.11.049 · Cited by 193
Zero energy buildings and mismatch compensation factors
Lund, H., Marszal-Pomianowska, A., & Heiselberg, P. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.03.006 · Cited by 173
D'Agostino, D., & Parker, D. (2018) · Energy · doi:10.1016/j.energy.2018.02.020 · Cited by 166
Self-citationD’Agostino, D. (2015) · Journal of Building Engineering · doi:10.1016/j.jobe.2015.01.002 · Cited by 145
Self-citation
Cited by
Scalable thermochromic smart windows with passive radiative cooling regulation
Wang, S., Jiang, T., Meng, Y., Yang, R., Tan, G., & Long, Y. (2021) · Science · doi:10.1126/science.abg0291 · Cited by 1,058
Review of 50 years of EU energy efficiency policies for buildings
Economidou, M., Todeschi, V., Bertoldi, P., D'Agostino, D., Zangheri, P., & Castellazzi, L. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110322 · Cited by 640
Self-citationAssessment of the renewable energy generation towards net-zero energy buildings: A review
Ahmed, A., Ge, T., Peng, J., Yan, W.-C., Tee, B. T., & You, S. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111755 · Cited by 450
Feng, W., Zhang, Q., Ji, H., Wang, R., Zhou, N., Ye, Q., Hao, B., Li, Y., Luo, D., & Lau, S. S. Y. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109303 · Cited by 329
Pang, Y., He, T., Liu, S., Zhu, X., & Lee, C. (2024) · Advanced Science · doi:10.1002/advs.202306574 · Cited by 60
Metadata
- Authors
- D'Agostino, D., & Mazzarella, L.
- Venue
- Journal of Building Engineering
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 21
- Pages
- 200-212
- ISSN
- 2352-7102 (ISSN-L)
- OpenAlex
- W2898387969
- Cited by
- 392
- References
- 13
- FWCI
- 28.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What is a Nearly zero energy building? Overview, implementation and comparison of definitions. https://app.cochat.ai/papers/10.1016/j.jobe.2018.10.019
- The paper
- D'Agostino, D., & Mazzarella, L. (2019). What is a Nearly zero energy building? Overview, implementation and comparison of definitions. Journal of Building Engineering. https://doi.org/10.1016/j.jobe.2018.10.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.