The DOI matches its Crossref record; 211 of the 211 references it cites were found in a registry or an index.
Indoor air quality and health in schools: A critical review for developing the roadmap for the future school environment
Open accessAbstract
Several research studies have ranked indoor pollution among the top environmental risks to public health in recent years. Good indoor air quality is an essential component of a healthy indoor environment and significantly affects human health and well-being. Poor air quality in such environments may cause respiratory disease for millions of pupils around the globe and, in the current pandemic-dominated era, require ever more urgent actions to tackle the burden of its impacts. The poor indoor quality in such environments could result from poor management, operation, maintenance, and cleaning. Pupils are a different segment of the population from adults in many ways, and they are more exposed to the poor indoor environment: They breathe in more air per unit weight and are more sensitive to heat/cold and moisture. Thus, their vulnerability is higher than adults, and poor conditions may affect proper development. However, a healthy learning environment can reduce the absence rate, improves test scores, and enhances pupil/teacher learning/teaching productivity. In this article, we analyzed recent literature on indoor air quality and health in schools, with the primary focus on ventilation, thermal comfort, productivity, and exposure risk. This study conducts a comprehensive review to summarizes the existing knowledge to highlight the latest research and solutions and proposes a roadmap for the future school environment. In conclusion, we summarize the critical limitations of the existing studies, reveal insights for future research directions, and propose a roadmap for further improvements in school air quality. More parameters and specific data should be obtained from in-site measurements to get a more in-depth understanding at contaminant characteristics. Meanwhile, site-specific strategies for different school locations, such as proximity to transportation routes and industrial areas, should be developed to suit the characteristics of schools in different regions. The socio-economic consequences of health and performance effects on children in classrooms should be considered. There is a great need for more comprehensive studies with larger sample sizes to study on environmental health exposure, student performance, and indoor satisfaction. More complex mitigation measures should be evaluated by considering energy efficiency, IAQ and health effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–211 of 211
Malayeri, M., Lee, C., & Haghighat, F. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.128265 · Cited by 22
Self-citationHealth effects of mold exposure in public schools
Santilli, J. G. (2002) · Current Allergy and Asthma Reports · doi:10.1007/s11882-002-0085-z · Cited by 19
Hwang, S. H., Lee, G. B., Kim, I. S., & Park, W. M. (2016) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2016.1231145 · Cited by 18
Photovoltaic systems in school units of Greece and their consequences
Economou, A. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.09.028 · Cited by 17
Xiong, J., Yao, R., Wang, W., Yu, W., & Li, B. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.120331 · Cited by 12
Self-citationLu, K. H., Vu, D. C., Nguyen, Q. P. H., & Vo, X. T. (2021) · Atmosphere · doi:10.3390/atmos12111421 · Cited by 12
Chemical Composition and Source Apportionment of PM10 in a Green-Roof Primary School Building
Barmparesos, N., Saraga, D. E., Karavoltsos, S., Maggos, T., Assimakopoulos, V. D., Sakellari, A., Bairachtari, K. A., & Assimakopoulos, M.-N. (2020) · Applied Sciences · doi:10.3390/app10238464 · Cited by 11
Emerging and Re-emerging Infections in Children
Chen, C. C., & Whitehead, A. (2021) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2021.04.002 · Cited by 11
Air fungal contamination in two elementary schools in Lisbon, Portugal
Viegas, C., Veríssimo, C., Rosado, L., & Santos, C. (2010) · WIT transactions on ecology and the environment · doi:10.2495/air100271 · Cited by 7
Effects of Classroom Air Quality on Learning in Schools
Wargocki, P. L. (2021) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_65-1 · Cited by 3
Self-citationSadrizadeh, S., Afshari, A., & Iqbal, A. (2017) · VBN Forskningsportal (Aalborg Universitet) · Cited by 1
Self-citation
Metadata
- Authors
- Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., Kumar, P., Malayeri, M., Nasiri, F., Ruud, M., Sadeghian, P., Wargocki, P., Xiong, J., Yu, W., & Li, B.
- Venue
- Journal of Building Engineering
- Publisher
- Elsevier BV
- Published
- 2022-10
- Volume
- 57
- Pages
- 104908
- ISSN
- 2352-7102 (ISSN-L)
- OpenAlex
- W4284895559
- Cited by
- 375
- References
- 211
- FWCI
- 25.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.