Diagnosis of Vertical Root Fractures by Cone-beam Computed Tomography in Root-filled Teeth with Confirmation by Direct Visualization: A Systematic Review and Meta-Analysis
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
AIM The purpose of this review was to determine the diagnostic accuracy of CBCT in detecting vertical root fracture in root filled teeth when compared to a reference standard (direct visualization). METHODS Electronic searches were performed in Medline, Scopus, Cochrane and Grey Literature for English language articles till June 2020. Prospective and retrospective clinical studies using CBCT to diagnose VRF in root filled teeth were included. Case reports and in-vitro studies were excluded. Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the risk of bias (RB) and applicability concerns. Meta-analysis was done using STATA 16.1 software via MIDAS 3.0 package and METANDI module. Publication bias was evaluated using Deeks funnel plot analysis. Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) was done to evaluate certainty of evidence. This systematic review was registered in the Open Science Framework (10.17605/OSF.IO/7JKE2). RESULTS 8 articles were included in this systematic review and meta-analysis. RB assessment showed that 5 articles in the patient selection domain had low RB with low applicability concern. In the index test and reference standard domains, 7 articles had moderate RB with moderate applicability concern. 3 articles had high RB in the flow and timing domain. There was no publication bias. CBCT had pooled sensitivity and specificity of 0.78 (95% CI =0.64-0.88) and 0.80 (95% CI =0.63-0.91) respectively and accuracy of 0.86 (95% CI =0.83-0.89). CBCT also had pooled positive and negative likelihood ratios of 4 and 0.2 respectively. In GRADE analysis, the quality of evidence was low for sensitivity and moderate for specificity when CBCT was used for diagnosis of VRF. CONCLUSIONS Overall quality assessment of included articles showed that in patient selection domain, the risk of bias was low and it was moderate in index test and reference standard domains. Evidence from this updated systematic review and meta analysis indicates that CBCT is still not a good tool for diagnosing VRF in root filled teeth as compared to direct visualization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
GRADE guidelines: 1. Introduction—GRADE evidence profiles and summary of findings tables
Guyatt, G., Oxman, A. D., Akl, E. A., Kunz, R., Vist, G., Brozek, J., Norris, S., Falck-Ytter, Y., Glasziou, P., & deBeer, H. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.04.026 · Cited by 10,681
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
Generalized Latent Variable Modeling: Multilevel, Longitudinal, and Structural Equation Models
Skrondal, A., & Rabe‐Hesketh, S. (2004) · Thammasat University Digital Collections · Cited by 1,505
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
(1975) · New England Journal of Medicine · doi:10.1056/nejm197507312930513 · Cited by 1,017
A unification of models for meta-analysis of diagnostic accuracy studies
Harbord, R. M., Deeks, J. J., Egger, M., Whiting, P., & Sterne, J. A. C. (2007) · Biostatistics · doi:10.1093/biostatistics/kxl004 · Cited by 751
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Interpreting results and drawing conclusions
Schünemann, H. J., Vist, G. E., Higgins, J. P., Santesso, N., Deeks, J. J., Glasziou, P., Akl, E. A., Guyatt, G. H., & on behalf of the Cochrane GRADEing Methods Group (2019) · Cochrane Handbook for Systematic Reviews of Interventions · doi:10.1002/9781119536604.ch15 · Cited by 595
The Bagplot: A Bivariate Boxplot
Rousseeuw, P. J., Ruts, I., & Tukey, J. W. (1999) · The American Statistician · doi:10.2307/2686061 · Cited by 568
Leeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346
Brożek, J. L., Akl, E. A., Jaeschke, R., Lang, D. M., Bossuyt, P., Glasziou, P., Helfand, M., Ueffing, E., Alonso‐Coello, P., Meerpohl, J., et al. (2009) · Allergy · doi:10.1111/j.1398-9995.2009.02083.x · Cited by 270
Tsesis, I., Rosen, E., Tamse, A., Taschieri, S., & Kfir, A. (2010) · Journal of Endodontics · doi:10.1016/j.joen.2010.05.003 · Cited by 245
Macaskill, P. (2004) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2003.12.019 · Cited by 210
Use of cone-beam volumetric tomography in the diagnosis of root fractures
Bernardes, R. A., de Moraes, I. G., Húngaro Duarte, M. A., Azevedo, B. C., de Azevedo, J. R., & Bramante, C. M. (2009) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2009.01.017 · Cited by 195
Prevalence of vertical root fractures in extracted endodontically treated teeth
Coppens, C., & Moor, R. J. G. D. (2003) · Ghent University Academic Bibliography (Ghent University) · Cited by 176
Iatrogenic vertical root fractures in endodontically treated teeth
Tamse, A. (1988) · Dental Traumatology · doi:10.1111/j.1600-9657.1988.tb00321.x · Cited by 161
Chang, E., Lam, E. W. N., Shah, P. S., & Azarpazhooh, A. (2015) · Journal of Endodontics · doi:10.1016/j.joen.2015.10.005 · Cited by 152
Root fractures due to corrosion Diagnostic aspects
RUD, J., & OMNELL, K. (1970) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.1970.tb02088.x · Cited by 132
Talwar, S., Utneja, S., Nawal, R. R., Kaushik, A., Srivastava, D., & Oberoy, S. S. (2015) · Journal of Endodontics · doi:10.1016/j.joen.2015.09.012 · Cited by 129
Original Paper: A likelihood ratio approach to meta-analysis of diagnostic studies
Stengel, D., Bauwens, K., Sehouli, J., Ekkernkamp, A., & Porzsolt, F. (2003) · Journal of Medical Screening · doi:10.1258/096914103321610806 · Cited by 118
Diagnostic accuracy of CBCT for tooth fractures: A meta-analysis
Long, H., Zhou, Y., Ye, N., Liao, L., Jian, F., Wang, Y., & Lai, W. (2013) · Journal of Dentistry · doi:10.1016/j.jdent.2013.11.024 · Cited by 74
How to Perform a Systematic Review and Meta-analysis of Diagnostic Imaging Studies
Cronin, P., Kelly, A. M., Altaee, D. K., Foerster, B. R., Petrou, M., & Dwamena, B. A. (2018) · Academic Radiology · doi:10.1016/j.acra.2017.12.007 · Cited by 71
Prevalence‐dependent diagnostic accuracy measures
Li, J., Fine, J. P., & Safdar, N. (2007) · Statistics in Medicine · doi:10.1002/sim.2812 · Cited by 49
Ma, R. H., Ge, Z., & Li, G. (2015) · International Endodontic Journal · doi:10.1111/iej.12490 · Cited by 48
Metadata
- Authors
- PradeepKumar, A. R., Shemesh, H., Nivedhitha, M. S., Hashir, M. M. J., Arockiam, S., Uma Maheswari, T. N., & Natanasabapathy, V.
- Venue
- Journal of Endodontics
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 47
- Issue
- 8
- Pages
- 1198-1214
- ISSN
- 0099-2399 (ISSN-L)
- OpenAlex
- W3163621796
- Cited by
- 319
- References
- 29
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.