The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Accuracy of a Computer-Aided Surgical Simulation Protocol for Orthognathic Surgery: A Prospective Multicenter Study
Open accessAbstract
Purpose The purpose of this prospective multicenter study was to assess the accuracy of a computer-aided surgical simulation (CASS) protocol for orthognathic surgery. Materials and Methods The accuracy of the CASS protocol was assessed by comparing planned and postoperative outcomes of 65 consecutive patients enrolled from 3 centers. Computer-generated surgical splints were used for all patients. For the genioplasty, one center utilized computer-generated chin templates to reposition the chin segment only for patients with asymmetry. Standard intraoperative measurements were utilized without the chin templates for the remaining patients. The primary outcome measurements were linear and angular differences for the maxilla, mandible and chin when the planned and postoperative models were registered at the cranium. The secondary outcome measurements were: maxillary dental midline difference between the planned and postoperative positions; and linear and angular differences of the chin segment between the groups with and without the use of the template. The latter was measured when the planned and postoperative models were registered at mandibular body. Statistical analyses were performed, and the accuracy was reported using root mean square deviation (RMSD) and Bland and Altman's method for assessing measurement agreement. Results In the primary outcome measurements, there was no statistically significant difference among the 3 centers for the maxilla and mandible. The largest RMSD was 1.0mm and 1.5° for the maxilla, and 1.1mm and 1.8° for the mandible. For the chin, there was a statistically significant difference between the groups with and without the use of the chin template. The chin template group showed excellent accuracy with largest positional RMSD of 1.0mm and the largest orientational RSMD of 2.2°. However, larger variances were observed in the group not using the chin template. This was significant in anteroposterior and superoinferior directions, as in pitch and yaw orientations. In the secondary outcome measurements, the RMSD of maxillary dental midline positions was 0.9mm. When registered at the body of the mandible, the linear and angular differences of the chin segment between the groups with and without the use of the chin template were consistent with the results found in the primary outcome measurements. Conclusion Using the CASS protocol, the computerized plan can be accurately and consistently transferred to the patient to position the maxilla and mandible at the time of surgery. The computer-generated chin template provides more accuracy in repositioning the chin segment than the intraoperative measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Modern Practice in Orthognathic and Reconstructive Surgery
Bell, W. H., & Ferraro, J. W. (1993) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199308000-00030 · Cited by 523
Xia, J. J., Gateno, J., Teichgraeber, J. F., Christensen, A. M., Lasky, R. E., Lemoine, J. J., & Liebschner, M. A. K. (2007) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2006.10.005 · Cited by 249
Self-citationComputer-assisted three-dimensional surgical planning and simulation: 3D virtual osteotomy
Xia, J., Ip, H. H. S., Samman, N., Wang, D., Kot, C. S. B., Yeung, R. W. K., & Tideman, H. (2000) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0901-5027(00)80116-2 · Cited by 238
Self-citationA New Method of 3-D Cephalometry Part I: The Anatomic Cartesian 3-D Reference System
Swennen, G. R. J., Schutyser, F., Barth, E.-L., De Groeve, P., & De Mey, A. (2006) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200603000-00019 · Cited by 193
Development of a three-dimensional treatment planning system based on computed tomographic data
Troulis, M. J., Everett, P., Seldin, E. B., Kikinis, R., & Kaban, L. B. (2002) · International Journal of Oral and Maxillofacial Surgery · doi:10.1054/ijom.2002.0278 · Cited by 173
The precision of computer-generated surgical splints
Gateño, J., Xia, J., Teichgraeber, J. F., Rosen, A., Hultgren, B., & Vadnais, T. (2003) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(03)00240-4 · Cited by 147
Self-citationDistraction Osteogenesis of the Facial Skeleton
Bell, E. B. W. H., & Guerrero, C. A. (2006) · Medical Entomology and Zoology · Cited by 94
Xia, J. J., McGrory, J. K., Gateño, J., Teichgraeber, J. F., Dawson, B., Kennedy, K. A., Lasky, R. E., English, J. D., Kau, C. H., & McGrory, K. R. (2011) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2010.10.034 · Cited by 79
Self-citationDevelopment of a Technique for Recording and Transferring Natural Head Position in 3 Dimensions
Schatz, E. C., Xia, J. J., Gateño, J., English, J. D., Teichgraeber, J. F., & Garrett, F. A. (2010) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e3181ebcd0a · Cited by 52
Self-citationIn Vitro Evaluation of New Approach to Digital Dental Model Articulation
Chang, Y.-B., Xia, J. J., Gateño, J., Xiong, Z., Teichgraeber, J. F., Lasky, R. E., & Zhou, X. (2011) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2011.02.109 · Cited by 23
Self-citation
Cited by
3D scanning applications in medical field: A literature-based review
Haleem, A., & Javaid, M. (2019) · Clinical Epidemiology and Global Health · doi:10.1016/j.cegh.2018.05.006 · Cited by 266
Metadata
- Authors
- Hsu, S. S.-P., Gateno, J., Bell, R. B., Hirsch, D. L., Markiewicz, M. R., Teichgraeber, J. F., Zhou, X., & Xia, J. J.
- Venue
- Journal of Oral and Maxillofacial Surgery
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 71
- Issue
- 1
- Pages
- 128-142
- ISSN
- 0278-2391 (ISSN-L)
- OpenAlex
- W1982424300
- Cited by
- 435
- References
- 12
- FWCI
- 22.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.