Dissolution test for lamivudine tablets: Optimization and statistical analysis
Abstract
A comparison of different methods for dissolution test used by five different manufacturer laboratories of lamivudine tablets is made, evaluated, and discussed. Dissolution medium (water and hydrochloric acid pH 1.2), apparatus (paddles and baskets) and time (30 and 60 min) were analyzed. The determination was accomplished by spectrophotometry at 270 nm. Analysis of variance (ANOVA) factorial design 5 x 2 x 2 x 2 with six repetitions, with post hoc multiple comparisons between means conducted by Duncan test at 0.05 significance level was used. After the comparative analysis of the results, optimal dissolution conditions were determined as follows: water as dissolution medium, paddles at the stirring speed of 50 rpm as apparatus and time of 30 min. The method was applied to the dissolution test of samples from eleven batches of tablets, produced by five different laboratories.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dissolution tests and dissolution profiles are important for establishing pharmaceutical equivalence.
“For that reason, the importance of dissolution tests and dissolution profile for the establishment of pharmaceutical equivalence must be highlighted 3, 4 .”
From Evaluation and comparison of in-vitro dissolution profiles for different brands of amoxicillin capsules (2013) · cites this paper as [3]
Cited by
Sorted by citations
Kassaye, L., & Genete, G. (2013) · African Health Sciences · doi:10.4314/ahs.v13i2.25 · Cited by 80 · see citing works
- Authors
- Fernandes, C., Junqueira, R. G., Campos, L. M. M., & Pianetti, G. A.
- Affiliations
- Universidade Federal de Minas Gerais (BR)
- Corresponding author
- Fernandes, Christian
- Venue
- Journal of Pharmaceutical and Biomedical Analysis
- Publisher
- Elsevier BV
- Published
- 2006-11
- Volume
- 42
- Issue
- 5
- Pages
- 601-606
- ISSN
- 0731-7085 (ISSN-L)
- OpenAlex
- W2045046597
- Cited by
- 20
- References
- 0
- Citations by year
- 2021: 1 · 2020: 1 · 2017: 1 · 2014: 1 · 2013: 4 · 2012: 2
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Pharmaceutical and Biomedical Analysis (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Pharmaceutical Quality and Counterfeiting
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Drug Solubulity and Delivery Systems
- Keywords
- dissolution testing, dissolution media, paddle apparatus, dissolution time, method optimization, factorial design, spectrophotometric determination, pharmaceutical quality control, interlaboratory comparison
- MeSH terms
- Analysis of Variance, Hydrochloric Acid, Hydrogen-Ion Concentration, Quality Control, Solubility, Tablets, Water, Lamivudine, Anti-HIV Agents
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review