The DOI matches its Crossref record.
Determination of thiols and disulfides via HPLC quantification of 5-thio-2-nitrobenzoic acid
Open accessAbstract
This work presents an assay for total thiols and total disulfides in biological samples via HPLC quantification of 5-thio-2-nitrobenzoic acid (TNB) derived from the reaction of thiols with 5,5′-dithiobis(2-nitrobenzoic acid) (DTNB, Ellman’s reagent). This method also provides simultaneous quantification of glutathione (GSH) via the measurement of the GSH DTNB adduct (GSH-TNB). By using 326 nm as the detecting wavelength, the HPLC detection limit for TNB and the GSH-TNB adduct was determined to be 15 pmol and 7.5 pmol respectively. A recovery study with OVCAR-3 cells revealed that the recovery yields for TNB in the procedures for determining non-protein thiols, protein thiols, non-protein disulfides, and protein disulfides were 99.4±1.2% (n = 3), 98.1±5.0% (n = 3), 95.6±0.9% (n = 3), and 96.6±2.3% (n = 3) respectively. The recovery yield for GSH-TNB in the procedures for determining non-protein thiols, protein thiols, non-protein disulfides, and protein disulfides were 99.0±0.3% (n = 3), 95.1±4.9% (n = 3), 96.8±0.6% (n = 3), and 95.1±2.9% (n = 3) respectively. The reproducibility, expressed as the relative standard deviation for the analyte, for TNB was determined to be 2.8% (n = 6) for non-protein thiols, 3.9% (n = 6) for protein thiols, 3.6% (n = 6) for non-protein disulfides and 4.6% (n = 6) for protein disulfides. The reproducibility for GSH-TNB was determined to be 1.6% (n= 6) for non-protein thiols and 2.6% (n = 6) for non-protein disulfides. By comparing the amount of GSH determined in a biological sample before NaBH4 reduction with that after the reduction, this method can provide information associated with thiol glutathionylation which would be useful for protein glutathionylation study. This method should be applicable to cellular, subcellular, protein, or other biomatrix samples for thiol and disulfide quantification and will be a useful analytical method in the study of thiol redox state and thiol glutathionylation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Thiol-addition reactions and their applications in thiol recognition
Yin, C., Huo, F., Zhang, J., Martínez-Máñez, R., Yang, Y., Lv, H., & Li, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60055f · Cited by 554
Weber, D., Stuetz, W., Toussaint, O., Debacq-Chainiaux, F., Dollé, M. E. T., Jansen, E., Gonos, E. S., Franceschi, C., Sikora, E., Hervonen, A., et al. (2017) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2017/1401452 · Cited by 46
Metadata
- Authors
- Chen, W., Zhao, Y., Seefeldt, T., & Guan, X.
- Venue
- Journal of Pharmaceutical and Biomedical Analysis
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 48
- Issue
- 5
- Pages
- 1375-1380
- ISSN
- 0731-7085 (ISSN-L)
- OpenAlex
- W2088435647
- Cited by
- 183
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of thiols and disulfides via HPLC quantification of 5-thio-2-nitrobenzoic acid. https://app.cochat.ai/papers/10.1016/j.jpba.2008.08.033
- The paper
- Chen, W., Zhao, Y., Seefeldt, T., & Guan, X. (2008). Determination of thiols and disulfides via HPLC quantification of 5-thio-2-nitrobenzoic acid. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2008.08.033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.