Recent developments in green membrane-based extraction techniques for pharmaceutical and biomedical analysis
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
HIGHLIGHTSState‐of‐the‐art developments in membrane extraction are presented for pharmaceutical and biomedical analysis.Green membranes are classified according to porous and nonporous modes.Key aspects of modern versus classical approaches are thoroughly discussed.Pros and cons of each membrane extraction mode is explained. ABSTRACT Monitoring of target analytes (e.g., pharmaceuticals, endogenous compounds) present in biological samples usually requires a preliminary step toward analyte isolation from surrounding matrix and enrichment for trace analysis. Evident developments have been recently made to introduce novel “green” analytical approaches (which keep the requirements of Green Analytical Chemistry – GAC) being effective, economical, eco‐friendly, and amenable to hyphenated analytical instrumentations. Modern membrane‐based extraction techniques provide the smart options against classical sample preparations e.g., liquid‐liquid extraction (LLE).These approaches are more stable and allow trace determination of analytes in complex matrices (e.g., biological samples), with high extraction recovery and selectivity. Simultaneously, drawbacks of LLE such as large consumption of organic solvents and the need for tedious handling are eliminated. This paper thoroughly overviews important features and applications of membrane‐ based extraction techniques with special focus on pharmaceutical and biomedical analysis since 2013. Different driving forces of mass transfer across the membrane were summarized and membrane‐based extraction techniques were described along with their advantages/disadvantages as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Peng, J.-F., Liu, J.-F., Hu, X.-L., & Jiang, G.-B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.006 · Cited by 276
Yue, B., Rockwood, A. L., Sandrock, T., La’ulu, S. L., Kushnir, M. M., & Meikle, A. W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.098293 · Cited by 127
Khataei, M. M., Yamini, Y., Nazaripour, A., & Karimi, M. (2018) · Talanta · doi:10.1016/j.talanta.2017.09.068 · Cited by 113
Supramolecular solvent-based hollow fiber liquid phase microextraction of benzodiazepines
Rezaei, F., Yamini, Y., Moradi, M., & Daraei, B. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.026 · Cited by 110
Modern solutions in the field of microextraction using liquid as a medium of extraction
Płotka-Wasylka, J., Owczarek, K., & Namieśnik, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.08.010 · Cited by 109
Application of ionic liquids for liquid–liquid microextraction
Zhang, P., Hu, L., Lu, R., Zhou, W., & Gao, H. (2013) · Analytical Methods · doi:10.1039/c3ay40597d · Cited by 50
Cited by
Recent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Kaur, P., Kumar Pandey, D., Gupta, R. C., & Dey, A. (2019) · Industrial Crops and Products · doi:10.1016/j.indcrop.2019.02.055 · Cited by 48
Bioanalytical Applications of Microextraction Techniques: A Review of Reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Chromatographia · doi:10.1007/s10337-020-03884-1 · Cited by 40
Metadata
- Authors
- Tabani, H., Nojavan, S., Alexovič, M., & Sabo, J.
- Venue
- Journal of Pharmaceutical and Biomedical Analysis
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 160
- Pages
- 244-267
- ISSN
- 0731-7085 (ISSN-L)
- OpenAlex
- W2885963139
- Cited by
- 81
- References
- 8
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.