The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
XPS investigation of Nafion® membrane degradation
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, F., Hickner, M., Kim, Y. S., Zawodzinski, T. A., & McGrath, J. E. (2002) · Journal of Membrane Science · doi:10.1016/s0376-7388(01)00620-2 · Cited by 1,134
Advanced materials for improved PEMFC performance and life
Curtin, D. E., Lousenberg, R. D., Henry, T. J., Tangeman, P. C., & Tisack, M. E. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.01.023 · Cited by 786
Aging mechanisms and lifetime of PEFC and DMFC
Knights, S. D., Colbow, K. M., St-Pierre, J., & Wilkinson, D. P. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2003.09.033 · Cited by 753
Nanostructure of Nafion® membranes at different states of hydration
Gruger, A., Régis, A., Schmatko, T., & Colomban, P. (2001) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(01)00116-3 · Cited by 402
Aspects of the Chemical Degradation of PFSA Ionomers used in PEM Fuel Cells
Healy, J., Hayden, C., Xie, T., Olson, K., Waldo, R., Brundage, M., Gasteiger, H., & Abbott, J. (2005) · Fuel Cells · doi:10.1002/fuce.200400050 · Cited by 384
Durability of perfluorinated ionomer membrane against hydrogen peroxide
Kinumoto, T., Inaba, M., Nakayama, Y., Ogata, K., Umebayashi, R., Tasaka, A., Iriyama, Y., Abe, T., & Ogumi, Z. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.10.043 · Cited by 354
Perfluorosulfonated membrane (Nafion): FT-IR study of the state of water with increasing humidity
Laporta, M., Pegoraro, M., & Zanderighi, L. (1999) · Physical Chemistry Chemical Physics · doi:10.1039/a904460d · Cited by 335
Degradation Study of MEA for PEMFCs under Low Humidity Conditions
Endoh, E., Terazono, S., Widjaja, H., & Takimoto, Y. (2004) · Electrochemical and Solid-State Letters · doi:10.1149/1.1739314 · Cited by 321
Hübner, G., & Roduner, E. (1999) · Journal of Materials Chemistry · doi:10.1039/a807129b · Cited by 321
PEM Fuel Cell Pt∕C Dissolution and Deposition in Nafion Electrolyte
Bi, W., Gray, G. E., & Fuller, T. F. (2007) · Electrochemical and Solid-State Letters · doi:10.1149/1.2712796 · Cited by 244
Self-citation
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Recent Insights into Manganese Oxides in Catalyzing Oxygen Reduction Kinetics
Stoerzinger, K. A., Risch, M., Han, B., & Shao-Horn, Y. (2015) · ACS Catalysis · doi:10.1021/acscatal.5b01444 · Cited by 440
Tang, Q., Jiang, L., Liu, J., Wang, S., & Sun, G. (2014) · ACS Catalysis · doi:10.1021/cs400938s · Cited by 362
Supercapacitor performance of perovskite La1−xSrxMnO3
Lang, X., Mo, H., Hu, X., & Tian, H. (2017) · Dalton Trans. · doi:10.1039/c7dt03134c · Cited by 325
Shah, A. A., Ralph, T. R., & Walsh, F. C. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3077573 · Cited by 149
Metadata
- Authors
- Chen, C., Levitin, G., Hess, D. W., & Fuller, T. F.
- Venue
- Journal of Power Sources
- Publisher
- Elsevier BV
- Published
- 2007-06
- Volume
- 169
- Issue
- 2
- Pages
- 288-295
- ISSN
- 0378-7753 (ISSN-L)
- OpenAlex
- W2114001448
- Cited by
- 278
- References
- 24
- FWCI
- 13.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: XPS investigation of Nafion® membrane degradation. https://app.cochat.ai/papers/10.1016/j.jpowsour.2007.03.037
- The paper
- Chen, C., Levitin, G., Hess, D. W., & Fuller, T. F. (2007). XPS investigation of Nafion® membrane degradation. Journal of Power Sources. https://doi.org/10.1016/j.jpowsour.2007.03.037
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.