An easy-to-implement multi-point impedance technique for monitoring aging of lithium ion batteries
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The need for a quick yet informative technique for diagnosing the lithium-ion batteries is escalating. Conventional impedance-based diagnosis methods are usually time-demanding for a complete electrochemical impedance spectroscopy measurement and involve complicated calculations to extract battery information, which therefore have limited applications in battery monitoring. In this study, we propose a multi-point impedance technique, involving impedance measurement on three characteristic frequency points and being able to separate ohmic, contact and solid electrolyte interphase resistances. The characteristic frequency points are calibrated using distribution of relaxation time method. This multi-point impedance technique holds potential for large-scale high-throughput battery monitoring and screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ageing mechanisms in lithium-ion batteries
Vetter, J., Novák, P., Wagner, M. R., Veit, C., Möller, K.-C., Besenhard, J. O., Winter, M., Wohlfahrt-Mehrens, M., Vogler, C., & Hammouche, A. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.01.006 · Cited by 3,987
Characterizing aging effects of lithium ion batteries by impedance spectroscopy
Tröltzsch, U., Kanoun, O., & Tränkler, H.-R. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2005.02.148 · Cited by 427
Spinner, N. S., Love, C. T., Rose-Pehrsson, S. L., & Tuttle, S. G. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.06.003 · Cited by 118
State-of-health monitoring of 18650 4S packs with a single-point impedance diagnostic
Love, C. T., Virji, M. B. V., Rocheleau, R. E., & Swider-Lyons, K. E. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.05.033 · Cited by 113
Cited by
Zhang, Y., Tang, Q., Zhang, Y., Wang, J., Stimming, U., & Lee, A. A. (2020) · Nature Communications · doi:10.1038/s41467-020-15235-7 · Cited by 889
Ge, M.-F., Liu, Y., Jiang, X., & Liu, J. (2021) · Measurement · doi:10.1016/j.measurement.2021.109057 · Cited by 418
Yao, L., Fang, Z., Xiao, Y., Hou, J., & Fu, Z. (2021) · Energy · doi:10.1016/j.energy.2020.118866 · Cited by 332
Li, X., Yuan, C., & Wang, Z. (2020) · Energy · doi:10.1016/j.energy.2020.117852 · Cited by 321
State-of-Health Estimation Based on Differential Temperature for Lithium Ion Batteries
Tian, J., Xiong, R., & Shen, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2978493 · Cited by 310
Metadata
- Authors
- Zhou, X., Pan, Z., Han, X., Lu, L., & Ouyang, M.
- Venue
- Journal of Power Sources
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 417
- Pages
- 188-192
- ISSN
- 0378-7753 (ISSN-L)
- OpenAlex
- W2902265065
- Cited by
- 141
- References
- 4
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An easy-to-implement multi-point impedance technique for monitoring aging of lithium ion batteries. https://app.cochat.ai/papers/10.1016/j.jpowsour.2018.11.087
- The paper
- Zhou, X., Pan, Z., Han, X., Lu, L., & Ouyang, M. (2019). An easy-to-implement multi-point impedance technique for monitoring aging of lithium ion batteries. Journal of Power Sources. https://doi.org/10.1016/j.jpowsour.2018.11.087
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.