The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A multi-fault diagnostic method based on an interleaved voltage measurement topology for series connected battery packs
Abstract
Abstract For the safe operation of electric vehicles, it is of critical importance to quickly detect and accurately identify different types of faults in battery packs. However, the performance characteristics of many faults in the battery system are hidden and similar, therefore a false positive fault detection happens occasionally. This paper presents a multi-fault diagnostic strategy based on an interleaved voltage measurement topology and improved correlation coefficient method, which can diagnose several types of faults (i.e. the internal/external short circuit, sensor faults and connection faults). The proposed voltage measurement method can correlate each battery and contact resistance with two different sensors respectively, so as to accurately identify the location and type of the faults. In order to eliminate the effect of battery inconsistencies and measurement error, the improved correlation coefficient method is utilized to monitor fault signatures. The non-model method proposed in this paper can avoid the aliasing phenomenon and has high sensitivity and robustness. Both theoretical analysis and experimental results validate the feasibility and advantages of the multi-fault diagnostic method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on prognostics and health monitoring of Li-ion battery
Zhang, J., & Lee, J. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.03.101 · Cited by 792
Internal short circuit detection for battery pack using equivalent parameter and consistency method
Ouyang, M., Zhang, M., Feng, X., Lu, L., Li, J., He, X., & Zheng, Y. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2015.06.087 · Cited by 309
Zhang, W., Shi, W., & Ma, Z. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2015.04.148 · Cited by 178
Cited by
Hu, X., Zhang, K., Liu, K., Lin, X., Dey, S., & Onori, S. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2020.2964814 · Cited by 580
Xiong, R., Sun, W., Yu, Q., & Sun, F. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115855 · Cited by 481
Hossain Lipu, M. S., Hannan, M. A., Karim, T. F., Hussain, A., Saad, M. H. M., Ayob, A., Miah, M. S., & Indra Mahlia, T. M. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.126044 · Cited by 446
Li, D., Zhang, Z., Liu, P., Wang, Z., & Zhang, L. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3008194 · Cited by 345
Yao, L., Fang, Z., Xiao, Y., Hou, J., & Fu, Z. (2021) · Energy · doi:10.1016/j.energy.2020.118866 · Cited by 332
Metadata
- Authors
- Kang, Y., Duan, B., Zhou, Z., Shang, Y., & Zhang, C.
- Venue
- Journal of Power Sources
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 417
- Pages
- 132-144
- ISSN
- 0378-7753 (ISSN-L)
- OpenAlex
- W2912409471
- Cited by
- 191
- References
- 3
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multi-fault diagnostic method based on an interleaved voltage measurement topology for series connected battery packs. https://app.cochat.ai/papers/10.1016/j.jpowsour.2019.01.058
- The paper
- Kang, Y., Duan, B., Zhou, Z., Shang, Y., & Zhang, C. (2019). A multi-fault diagnostic method based on an interleaved voltage measurement topology for series connected battery packs. Journal of Power Sources. https://doi.org/10.1016/j.jpowsour.2019.01.058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.