Abstract
The accuracy of quantification obtained using the iTRAQ labelling methodology for measuring protein ratios more extreme than 1:1 was investigated. A comparison of nLC-ESI MSMS and nLC-MALDI MSMS analysis routes was performed. A fixed concentration of a standard six protein mix was spiked with two proteins at a range of concentrations. The two data analysis programmes, Mascot and ProteinPilot Paragon, were also compared. Whilst the lower ratios could be measured accurately, greater discrepancies were seen for the higher ratios, particularly by nLC-ESI MSMS. Filtering out the weaker reporter ion signals improved the accuracy of the ratios: this is likely due to several factors which are explored in more detail. Overall, analysis by nLC-MALDI MSMS followed by Mascot interpretation gave the most accurate results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Cited by
McAlister, G. C., Nusinow, D. P., Jedrychowski, M. P., Wühr, M., Huttlin, E. L., Erickson, B. K., Rad, R., Haas, W., & Gygi, S. P. (2014) · Analytical Chemistry · doi:10.1021/ac502040v · Cited by 1,263
MS3 eliminates ratio distortion in isobaric multiplexed quantitative proteomics
Ting, L., Rad, R., Gygi, S. P., & Haas, W. (2011) · Nature Methods · doi:10.1038/nmeth.1714 · Cited by 1,009
Quantitative Proteomic Analysis of Histone Modifications
Huang, H., Lin, S., Garcia, B. A., & Zhao, Y. (2015) · Chemical Reviews · doi:10.1021/cr500491u · Cited by 370
Stable isotope labelling methods in mass spectrometry-based quantitative proteomics
Chahrour, O., Cobice, D., & Malone, J. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.04.013 · Cited by 267
Tortoriello, G., Morris, C. V., Alpar, A., Fuzik, J., Shirran, S. L., Calvigioni, D., Keimpema, E., Botting, C. H., Reinecke, K., Herdegen, T., et al. (2014) · The EMBO Journal · doi:10.1002/embj.201386035 · Cited by 255
Self-citation
Metadata
- Authors
- Shirran, S. L., & Botting, C. H.
- Venue
- Journal of Proteomics
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 73
- Issue
- 7
- Pages
- 1391-1403
- ISSN
- 1874-3919 (ISSN-L)
- OpenAlex
- W2069684499
- Cited by
- 57
- References
- 1
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of the accuracy of iTRAQ quantification by nLC-ESI MSMS and nLC-MALDI MSMS methods. https://app.cochat.ai/papers/10.1016/j.jprot.2010.03.003
- The paper
- Shirran, S. L., & Botting, C. H. (2010). A comparison of the accuracy of iTRAQ quantification by nLC-ESI MSMS and nLC-MALDI MSMS methods. Journal of Proteomics. https://doi.org/10.1016/j.jprot.2010.03.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.