CoChat

Quantitative accuracy in mass spectrometry based proteomics of complex samples: The impact of labeling and precursor interference

Open access
Sandberg, AnnSofi, Branca, Rui M.M., Lehtiö, Janne, Forshed, Jenny · 2014 · Journal of Proteomics
Cited by 88

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Knowing the limit of quantification is important to accurately judge the results from proteomics studies. In order to investigate isobaric labels in combination with peptide pre-fractionation by high resolution isoelectric focusing in terms of limit of detection, quantitative accuracy and how to improve it, we used a human cell lysate spiked with 57 protein standards providing reference points across a wide concentration range. Specifically, the impact of precursor mixing (isolation interference and reporter ion interference) on quantitative accuracy was investigated by co-analyzing iTRAQ (8-plex) and TMT (6-plex) labeled peptides. A label-free analysis was also performed. Peptides, labeled or label-free, were analyzed by LC-MS/MS (Orbitrap Velos). We identified 3386 proteins by the label-free approach, 4466 with iTRAQ and 5961 with TMT. A linear range of quantification down to 1fmol was indicated for both isobaric and label-free analysis workflows, with an upper limit exceeding 60fmol. Our results indicate that 6-plex TMT is more sensitive than 8-plex iTRAQ. For isobaric labels, quantitative accuracy was affected by precursor mixing. Based on our evaluation on precursor mixing and accuracy of isobaric label quantification, we propose a cut off of <30% isolation interference for peptide spectrum matches (PSMs) used in the quantification. BIOLOGICAL SIGNIFICANCE: Quantitative proteome analysis by mass spectrometry offers opportunities for biological research. However, knowing the limit of quantification in biological samples is important to accurately judge the results. By using a high-complexity sample spiked with protein standards of known concentrations, we investigated the quantification limits of label-free and label-based peptide quantification, including an evaluation of precursor mixing and its impact on quantification accuracy by isobaric labels. We suggest limits of allowed precursor interference and believe that this study contributes with information useful in proteome quantification by mass spectrometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jprot.2013.10.035

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

Metadata

Authors
Sandberg, A., Branca, R. M. M., Lehtiö, J., & Forshed, J.
Venue
Journal of Proteomics
Publisher
Elsevier BV
Published
2014-01
Volume
96
Pages
133-144
ISSN
1874-3919 (ISSN-L)
OpenAlex
W2020263250
Cited by
88
References
14
FWCI
2.71
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.