Fabrication of carbon films with ∼500nm holes for cryo-EM with a direct detector device
Open accessThe DOI matches its Crossref record.
Abstract
Single particle electron cryomicroscopy (cryo-EM) is often performed using EM grids coated with a perforated or holey layer of amorphous carbon. Regular arrays of holes enable efficient cryo-EM data collection and several methods for the production of micropatterned holey-carbon film coated grids have been described. However, a new generation of direct detector device (DDD) electron microscope cameras can benefit from hole diameters that are smaller than currently available. Here we extend a previously proposed method involving soft lithography with a poly(dimethylsiloxane) (PDMS) stamp for the production of holey-carbon film coated EM grids. By incorporating electron-beam (e-beam) lithography and modifying the procedure, we are able to produce low-cost high-quality holey-carbon film coated EM grids with ∼500nm holes spaced 4μm apart centre-to-centre. We demonstrate that these grids can be used for cryo-EM. Furthermore, we show that by applying image shifts to obtain movies of the carbon regions beside the holes after imaging the holes, the contrast transfer function (CTF) parameters needed for calculation of high-resolution cryo-EM maps with a DDD can be obtained efficiently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
How cryo-EM is revolutionizing structural biology
Bai, X.-C., McMullan, G., & Scheres, S. H. W. (2015) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2014.10.005 · Cited by 936
Structure and conformational states of the bovine mitochondrial ATP synthase by cryo-EM
Zhou, A., Rohou, A., Schep, D. G., Bason, J. V., Montgomery, M. G., Walker, J. E., Grigorieff, N., & Rubinstein, J. L. (2015) · eLife · doi:10.7554/elife.10180 · Cited by 296
Self-citationElectron cryomicroscopy observation of rotational states in a eukaryotic V-ATPase
Zhao, J., Benlekbir, S., & Rubinstein, J. L. (2015) · Nature · doi:10.1038/nature14365 · Cited by 283
Self-citationStructure of V-ATPase from the mammalian brain
Abbas, Y. M., Wu, D., Bueler, S. A., Robinson, C. V., & Rubinstein, J. L. (2020) · Science · doi:10.1126/science.aaz2924 · Cited by 233
Self-citationAtomic model for the dimeric F O region of mitochondrial ATP synthase
Guo, H., Bueler, S. A., & Rubinstein, J. L. (2017) · Science · doi:10.1126/science.aao4815 · Cited by 225
Self-citation
Metadata
- Authors
- Marr, C. R., Benlekbir, S., & Rubinstein, J. L.
- Venue
- Journal of Structural Biology
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 185
- Issue
- 1
- Pages
- 42-47
- ISSN
- 1047-8477 (ISSN-L)
- OpenAlex
- W2043082114
- Cited by
- 91
- References
- 0
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of carbon films with ∼500nm holes for cryo-EM with a direct detector device. https://app.cochat.ai/papers/10.1016/j.jsb.2013.11.002
- The paper
- Marr, C. R., Benlekbir, S., & Rubinstein, J. L. (2014). Fabrication of carbon films with ∼500nm holes for cryo-EM with a direct detector device. Journal of Structural Biology. https://doi.org/10.1016/j.jsb.2013.11.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.