Asynchronous data acquisition and on-the-fly analysis of dose fractionated cryoEM images by UCSFImage
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Newly developed direct electron detection cameras have a high image output frame rate that enables recording dose fractionated image stacks of frozen hydrated biological samples by electron cryomicroscopy (cryoEM). Such novel image acquisition schemes provide opportunities to analyze cryoEM data in ways that were previously impossible. The file size of a dose fractionated image stack is 20 ~ 60 times larger than that of a single image. Thus, efficient data acquisition and on-the-fly analysis of a large number of dose-fractionated image stacks become a serious challenge to any cryoEM data acquisition system. We have developed a computer-assisted system, named UCSFImage4, for semi-automated cryo-EM image acquisition that implements an asynchronous data acquisition scheme. This facilitates efficient acquisition, on-the-fly motion correction, and CTF analysis of dose fractionated image stacks with a total time of ~60 seconds/exposure. Here we report the technical details and configuration of this system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Li, X., Grigorieff, N., & Cheng, Y. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.06.010 · Cited by 45 · cited 2×
“GPUs have previously been used to accelerate many aspects of cryoEM image processing (Li et al., 2010; Zhang et al., 2010).”
MethodSelf-citation
Cited by
Accelerated cryo-EM structure determination with parallelisation using GPUs in RELION-2
Kimanius, D., Forsberg, B. O., Scheres, S. H., & Lindahl, E. (2016) · eLife · doi:10.7554/elife.18722 · Cited by 901
TRPV1 structures in nanodiscs reveal mechanisms of ligand and lipid action
Gao, Y., Cao, E., Julius, D., & Cheng, Y. (2016) · Nature · doi:10.1038/nature17964 · Cited by 814
Self-citationStructure and mechanogating mechanism of the Piezo1 channel
Zhao, Q., Zhou, H., Chi, S., Wang, Y., Wang, J., Geng, J., Wu, K., Liu, W., Zhang, T., Dong, M.-Q., et al. (2018) · Nature · doi:10.1038/nature25743 · Cited by 628
Self-citationGui, M., Song, W., Zhou, H., Xu, J., Chen, S., Xiang, Y., & Wang, X. (2017) · Cell Research · doi:10.1038/cr.2016.152 · Cited by 589
Structure of the voltage-gated calcium channel Cav1.1 at 3.6 Å resolution
Wu, J., Yan, Z., Li, Z., Qian, X., Lu, S., Dong, M., Zhou, Q., & Yan, N. (2016) · Nature · doi:10.1038/nature19321 · Cited by 487
Metadata
- Authors
- Li, X., Zheng, S., Agard, D. A., & Cheng, Y.
- Venue
- Journal of Structural Biology
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 192
- Issue
- 2
- Pages
- 174-178
- ISSN
- 1047-8477 (ISSN-L)
- OpenAlex
- W1616271270
- Cited by
- 87
- References
- 1
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.