The DOI matches its Crossref record.
Vibration reduction by using the idea of phononic crystals in a pipe-conveying fluid
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 21
- Mead, 1970, Free wave propagation in periodically supported infinite beams, Journal of Sound and Vibration, 11, 181, 10.1016/S0022-460X(70)80062-1 · DOI
- Mead, 1986, A new method of analyzing wave propagation in periodic structures: applications to periodic Timoshenko beams and stiffened plates, Journal of Sound and Vibration, 104, 9, 10.1016/S0022-460X(86)80128-6 · DOI
- Mead, 1983, Coupled flexural–longitudinal wave motion in a periodic beam, Journal of Sound and Vibration, 90, 1, 10.1016/0022-460X(83)90399-1 · DOI
- Kushwaha, 1993, Acoustic band structure of periodic elastic composites, Physical Review Letters, 71, 2022, 10.1103/PhysRevLett.71.2022 · DOI
- Kushwaha, 1994, Theory of acoustic band structure of periodic elastic composites, Physical Review B, 49, 2313, 10.1103/PhysRevB.49.2313 · DOI
- Sigalas, 1992, Elastic and acoustic wave band structure, Journal of Sound and Vibration, 158, 377, 10.1016/0022-460X(92)90059-7 · DOI
- Liu, 2000, Locally resonant sonic materials, Science, 289, 1734, 10.1126/science.289.5485.1734 · DOI
- Goffaux, 2002, Evidence of Fano-like interference phenomena in locally resonant materials, Physical Review Letters, 88, 225502, 10.1103/PhysRevLett.88.225502 · DOI
- Hirsekorn, 2004, Modelling and simulation of acoustic wave propagation in locally resonant sonic materials, Ultrasonics, 42, 231, 10.1016/j.ultras.2004.01.014 · DOI
- Liu, 2002, Three-component elastic wave band-gap material, Physical Review B, 65, 165116, 10.1103/PhysRevB.65.165116 · DOI
- Wen, 2005, Theoretical and experimental investigation of flexural wave propagation in straight beams with periodic structures: application to a vibration isolation structure, Journal of Applied Physics, 97, 114907, 10.1063/1.1922068 · DOI
- Yu, 2006, Complete flexural vibration band gaps in membrane-like lattice structures, Physics Letters A, 357, 154, 10.1016/j.physleta.2006.04.034 · DOI
- Yu, 2006, Flexural vibration band gaps in Euler–Bernoulli beams with two-degree-of-freedom locally resonant structures, Physical Review B, 73, 064301, 10.1103/PhysRevB.73.064301 · DOI
- Koo, 1996, Vibration analysis of a 3-dimensional piping system conveying fluid by wave approach, International Journal of Pressure Vessels and Piping, 67, 249, 10.1016/0308-0161(95)00022-4 · DOI
- Koo, 1998, Vibration reduction by using periodic supports in a piping system, Journal of Sound and Vibration, 210, 53, 10.1006/jsvi.1997.1292 · DOI
- Kang, 2000, The influence of rotary inertia of concentrated masses on the natural vibrations of fluid-conveying pipes, Journal of Sound and Vibration, 238, 179, 10.1006/jsvi.2000.3019 · DOI
- Lee, 1997, A generalized treatment of the energetic of translating continua, part II: beams and fluid conveying pipes, Journal of Sound and Vibration, 204, 735, 10.1006/jsvi.1996.0946 · DOI
- Qiao, 2002, Vibratory characteristics of flexural non-uniform Euler–Bernoulli beams carrying an arbitrary number of spring-mass systems, International Journal of Mechanical Sciences, 44, 725, 10.1016/S0020-7403(02)00007-3 · DOI
- Yu, 2006, Flexural vibration band gaps in Timoshenko beams with locally resonant structures, Journal of Applied Physics, 100, 124901, 10.1063/1.2400803 · DOI
- Nougaoui, 1988, Complex band structure of acoustic waves in superlattices, Surface Science, 199, 623, 10.1016/0039-6028(88)90926-0 · DOI
- Wang, 2004, Two dimensional locally resonant phononic crystals with binary structures, Physical Review Letters, 93, 154302, 10.1103/PhysRevLett.93.154302 · DOI
Cited by
Sorted by citations
Vibration control of fluid-conveying pipes: a state-of-the-art review
Ding, H., & Ji, J. C. (2023) · Applied Mathematics and Mechanics · doi:10.1007/s10483-023-3023-9 · Cited by 132
“The above studies have shown that for a defined resonant frequency of a given fluid-conveying pipe, whether it is a periodic oscillator based on the local resonance theory([54,56]), or a single”
BackgroundMethodInfluential
Metadata
- Authors
- Yu, D., Wen, J., Zhao, H., Liu, Y., & Wen, X.
- Affiliations
- National University of Defense Technology (CN)
- Corresponding author
- Yu, Dianlong
- Venue
- Journal of Sound and Vibration
- Publisher
- Elsevier BV
- Published
- 2008-11
- Volume
- 318
- Issue
- 1-2
- Pages
- 193-205
- ISSN
- 0022-460X (ISSN-L)
- OpenAlex
- W2055456596
- Cited by
- 248
- References
- 0
- Citations by year
- 2026: 13 · 2025: 19 · 2024: 26 · 2023: 19 · 2022: 23 · 2021: 20 · 2020: 17 · 2019: 15 · 2018: 18 · 2017: 11 · 2016: 12 · 2015: 12 · 2014: 13 · 2013: 9 · 2012: 9
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Sound and Vibration (publishedVersion)
- Funders
- National Natural Science Foundation of China
- Topics
- Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Acoustic Wave Phenomena Research
- Physical Sciences › Engineering › Mechanical Engineering › Vibration and Dynamic Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Keywords
- phononic crystals, fluid-conveying pipes, flexural vibration, vibration suppression, band gap, Bragg scattering, local resonance, volume expansion, vibration control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review